Canada Spends Logo

Explore our Budget 2026 analysis

Grant: Discovery Grants Program - Individual

Université de Montréal

$33,000.00

Advanced applications of dual-energy computed tomography in radiation oncology

FY 2020-21

Summary
In radiation oncology, personalized 3D treatment planning is made possible by the scanning of every patient using medical imaging. The current clinical paradigm is based on computed tomography (CT), complemented by other imaging technologies when available and relevant. For treatment planning purposes, the images offer quantitative characterization of the patient's anatomy needed for radiation dose calculation and for organ delineation. Treatment planning is based on single energy CT (SECT): an x-ray source with a poly-energetic photon beam that crosses the patient and a detection system that measures the transmitted intensity. Recently, a new CT technology is commercially available; the dual-energy CT (DECT). This technology offers the possibility to simultaneously scan the patient using two different x-ray energies (two distinct sources and two distinct detection systems). Two different images are thus simultaneously obtained. At the CHUM, we installed one of the first DECT devices dedicated to radiation oncology treatment planning in 2013. Our research hypothesis is that this DECT can help improving treatment planning in radiation oncology on various levels. A research program was developed around this device involving medical physicists, radiation oncologists, medical residents and graduate students. The current grant proposal covers part of the global departmental research program. DECT for brachytherapy: The usage of DECT for prostate brachytherapy dosimetry calculation has been suggested by the AAPM TG186 report. We will build a Monte Carlo re-calculation platform to study improvements in dose calculation accuracy for low-dose rate brachytherapy. Reduction in artifact will be attempted based on standard decomposition methods proposed by Siemens and by in-house methods. The integration of this DECT data into the clinical system will be performed based on collaboration with Varian combining DECT data and Acuros. DECT for protontherapy: We will develop a Monte Carlo simulation environment to study the improvement in the accuracy of dose calculation due to DECT imaging. We will also study the integration of DECT image data into commercial protontherapy treatment planning systems. We have a research licenses from elekta and Varian on this specific subject. DECT for contrast-enhanced images: DECT imaging can provide a so-called “virtual non-contrast” (VNC) image. Based on tissue-decomposition methods, the VNC technique can transform an image initially filled with injected contrast agent into a virtual image without the contrast agent. Removing contrast agent from an image will also modify other high-Z regions of a given image. We will evaluate the value of this technique for specific anatomies. We will study the integration of such images into treatment planning systems. Improved VNC techniques will be developed in-house based on improved decomposition techniques.
Program
Discovery Grants Program - Individual
Location
Quebec, Canada
Recipient Type
Academia
Type
Grant
Source
NSERC's Awards Data

As published

Application id
RGPIN-2016-06363
Name nom
Carrier, Jean-François
Department département
Physique
Organization id
63
Institution établissement
Université de Montréal
Province en
Québec
Province fr
Québec
Country en
CANADA
Country fr
CANADA
Fiscal year exercice financier
2020
Competition year année de concours
2016
Award amount
33000
Program id
RGPIN
Program name en
Discovery Grants Program - Individual
Program name fr
Programme de subventions à la découverte - individuelles
Group en
Discovery grants programs
Group fr
Programmes de subventions à la découverte
Committee code
1505
Committee name en
Physics
Committee name fr
Physique
Area of application code
1211
Area of application group en
Advancement of knowledge
Area of application group fr
Avancement des connaissances
Area of application en
Medical and health sciences
Area of application fr
Sciences médicales et de la santé
Research subject code
3114
Research subject group en
Physics
Research subject group fr
Physique
Research subject en
Biological and Medical Physics
Research subject fr
Physique biologique et médicale
Installment
inst:5-6
Partie
2
Nb partie
6
Application title
Advanced applications of dual-energy computed tomography in radiation oncology
Keyword
NSERC
Application summary
In radiation oncology, personalized 3D treatment planning is made possible by the scanning of every patient using medical imaging. The current clinical paradigm is based on computed tomography (CT), complemented by other imaging technologies when available and relevant. For treatment planning purposes, the images offer quantitative characterization of the patient's anatomy needed for radiation dose calculation and for organ delineation. Treatment planning is based on single energy CT (SECT): an x-ray source with a poly-energetic photon beam that crosses the patient and a detection system that measures the transmitted intensity. Recently, a new CT technology is commercially available; the dual-energy CT (DECT). This technology offers the possibility to simultaneously scan the patient using two different x-ray energies (two distinct sources and two distinct detection systems). Two different images are thus simultaneously obtained. At the CHUM, we installed one of the first DECT devices dedicated to radiation oncology treatment planning in 2013. Our research hypothesis is that this DECT can help improving treatment planning in radiation oncology on various levels. A research program was developed around this device involving medical physicists, radiation oncologists, medical residents and graduate students. The current grant proposal covers part of the global departmental research program. DECT for brachytherapy: The usage of DECT for prostate brachytherapy dosimetry calculation has been suggested by the AAPM TG186 report. We will build a Monte Carlo re-calculation platform to study improvements in dose calculation accuracy for low-dose rate brachytherapy. Reduction in artifact will be attempted based on standard decomposition methods proposed by Siemens and by in-house methods. The integration of this DECT data into the clinical system will be performed based on collaboration with Varian combining DECT data and Acuros. DECT for protontherapy: We will develop a Monte Carlo simulation environment to study the improvement in the accuracy of dose calculation due to DECT imaging. We will also study the integration of DECT image data into commercial protontherapy treatment planning systems. We have a research licenses from elekta and Varian on this specific subject. DECT for contrast-enhanced images: DECT imaging can provide a so-called “virtual non-contrast” (VNC) image. Based on tissue-decomposition methods, the VNC technique can transform an image initially filled with injected contrast agent into a virtual image without the contrast agent. Removing contrast agent from an image will also modify other high-Z regions of a given image. We will evaluate the value of this technique for specific anatomies. We will study the integration of such images into treatment planning systems. Improved VNC techniques will be developed in-house based on improved decomposition techniques.