Canada Spends Logo

Explore our Budget 2026 analysis

Grant: Collaborative Research and Development Grants

University of Alberta

$25,000.00

Robotic Biobank

FY 2009-10

Summary
In the proposed project a novel robot will be developed to operate inside a freezer at -80C. It will provide a robotic high throughput solution to biobanking, i.e. storage and retrieval of biological samples for a variety of research projects. Biobanking is of strategic importance to a wide range of research activities in health science from genetic research to the development and evaluation of drugs and treatments. Storage of the biological sample tubes at a very low temperature and providing high frequency access to them at the same time introduces a dilemma to automation technology. These samples are sensitive to temperature fluctuations and therefore it is preferred for any automatic handling solution to be located completely inside the freezer. However, the extreme temperature makes such a solution challenging since many of the available technologies fail in such low temperature. In the proposed project, a novel robot is designed in such a way that all the sensitive parts including the actuators and sensors are stationary located outside the freezer. The mechanical power is transported using a single loop of cable. A coordinated movement of the stationary actuators determine the position of the robot end-effector. This has also significantly reduced the moving mass of the robot facilitating the high accelerations and velocities. It is expected that the robot provide 600 accesses to individual sample tubes per hour.
Program
Collaborative Research and Development Grants
Location
Alberta, Canada
Recipient Type
Academia
Type
Grant
Source
NSERC's Awards Data

As published

Application id
379853-2008
Name nom
Behzadipour, Saeed
Department département
Mechanical Engineering
Organization id
9
Institution établissement
University of Alberta
Province en
Alberta
Province fr
Alberta
Country en
CANADA
Country fr
CANADA
Fiscal year exercice financier
2009
Competition year année de concours
2008
Award amount
25000
Program id
CRDPJ
Program nane en
Collaborative Research and Development Grants
Program name fr
Subventions de recherche et développement coopérative
Group en
Research partnerships programs
Group fr
Programmes de partenariat
Committee code
96
Committee name en
RPP Internal Decision Cttee
Committee name fr
Cté de décision interne - PPR
Area of application code
1102
Area of application group en
Health, education and social services
Area of application group fr
Santé publique, éducation et services sociaux
Area of application en
Biomedical engineering
Area of application fr
Génie biomédical
Research subject code
2600
Research subject group en
Robotics
Research subject group fr
Robotique
Research subject en
Robotics
Research subject fr
Robotique
Partie
1
Nb partie
1
Application title
Robotic Biobank
Keyword
NA
Application summary
In the proposed project a novel robot will be developed to operate inside a freezer at -80C. It will provide a robotic high throughput solution to biobanking, i.e. storage and retrieval of biological samples for a variety of research projects. Biobanking is of strategic importance to a wide range of research activities in health science from genetic research to the development and evaluation of drugs and treatments. Storage of the biological sample tubes at a very low temperature and providing high frequency access to them at the same time introduces a dilemma to automation technology. These samples are sensitive to temperature fluctuations and therefore it is preferred for any automatic handling solution to be located completely inside the freezer. However, the extreme temperature makes such a solution challenging since many of the available technologies fail in such low temperature. In the proposed project, a novel robot is designed in such a way that all the sensitive parts including the actuators and sensors are stationary located outside the freezer. The mechanical power is transported using a single loop of cable. A coordinated movement of the stationary actuators determine the position of the robot end-effector. This has also significantly reduced the moving mass of the robot facilitating the high accelerations and velocities. It is expected that the robot provide 600 accesses to individual sample tubes per hour.