Grant: Discovery Grants Program - Individual
University of Western Ontario
$21,000.00
Single-pixel diffuse optical tomography scanner for dynamic functional imaging
FY 2018-19
Summary
Rational and Objective*Diffuse optical tomography (DOT) is a low-cost imaging modality that can provide three-dimensional (3D) images of tissue absorption, which, in the near-infrared range, is mainly due to hemoglobin and water. By measuring tissue absorption at multiple wavelengths, tomographic functional images can be generated and used to detect localized physiological abnormalities. It is this capacity to noninvasively image tissue physiological parameters (and to do so using safe, portable instruments) that makes DOT such an attractive technology. While DOT has numerous advantages, its widespread adoption as a functional imaging modality has been restricted by the current tradeoff between spatial and temporal resolution. That is, current methods can either acquire data at high speed with poor spatial resolution, or at millimeter resolution but with poor temporal resolution.*The objective of this research program is to address this critical limitation.*Research Plan*1) We will build a DOT scanner based on:* i) Early-photons imaging: These photons travel along paths that are confined close to the line of sight between the source and detector (quasi-mimicking X-rays), which reduces image blurring and significantly improves spatial resolution.* ii) Wide-field patterned illumination: A digital micro-mirror device (DMD), made of a 2D array of micro-mirrors that can be individually turned ON or OFF, will be used to generate wide-field patterned illumination on the surface of the tissue. We will leverage recent advances in DMDs technology that produced units that can generate light patterns at very high speed (up to 23 kHz) with high light output (up to 48%), to build a fast and efficient illumination system.* iii) Compressive detection: Light transmitted through the tissue will be projected onto a 2nd DMD (to spatially encode the light intensity), then integrated by a single photodetector. Notice that we will be using a single-pixel camera to generate 3D images without scanning or multiplexing.*2) We will develop an image reconstruction software based on accurate Monte Carlo modeling of early-photons propagation in tissue.*3) The spatial resolution of the scanner will be quantified using tissue-mimicking phantoms with spatially-resolved features.*4) The dynamic imaging capability of the system will be tested in an animal model of localized ischemia.*Impact*The research program detailed in this proposal will lead to the development of a DOT scanner capable of fast 3D imaging of thick tissue (up to 60-mm thickness) with millimeter resolution. Such a scanner will enable dynamic imaging of molecular tracers to develop methods for i) small animal molecular imaging, ii) monitoring treatment response in inflammatory arthritis, and iii) predicting response to chemotherapy in breast cancer.*
Program
Discovery Grants Program - Individual
Recipient
Location
Ontario, Canada
Recipient Type
Academia
Type
Grant
Source
NSERC's Awards Data
As published
Application id
RGPIN-2017-06337
Name nom
Diop, Mamadou
Department département
Medical Biophysics
Organization id
36
Institution établissement
University of Western Ontario
Province en
Ontario
Province fr
Ontario
Country en
CANADA
Country fr
CANADA
Fiscal year exercice financier
2018
Competition year année de concours
2017
Award amount
21000
Program id
RGPIN
Program name en
Discovery Grants Program - Individual
Program name fr
Programme de subventions à la découverte - individuelles
Group en
Discovery grants programs
Group fr
Programmes de subventions à la découverte
Committee code
1505
Committee name en
Physics
Committee name fr
Physique
Area of application code
1102
Area of application group en
Health, education and social services
Area of application group fr
Santé publique, éducation et services sociaux
Area of application en
Biomedical engineering
Area of application fr
Génie biomédical
Research subject code
1900
Research subject group en
Biomedical engineering
Research subject group fr
Génie biomédical
Research subject en
Biomedical engineering
Research subject fr
Génie biomédical
Partie
2
Nb partie
5
Application title
Single-pixel diffuse optical tomography scanner for dynamic functional imaging
Keyword
NSERC
Application summary
Rational and Objective*Diffuse optical tomography (DOT) is a low-cost imaging modality that can provide three-dimensional (3D) images of tissue absorption, which, in the near-infrared range, is mainly due to hemoglobin and water. By measuring tissue absorption at multiple wavelengths, tomographic functional images can be generated and used to detect localized physiological abnormalities. It is this capacity to noninvasively image tissue physiological parameters (and to do so using safe, portable instruments) that makes DOT such an attractive technology. While DOT has numerous advantages, its widespread adoption as a functional imaging modality has been restricted by the current tradeoff between spatial and temporal resolution. That is, current methods can either acquire data at high speed with poor spatial resolution, or at millimeter resolution but with poor temporal resolution.*The objective of this research program is to address this critical limitation.*Research Plan*1) We will build a DOT scanner based on:* i) Early-photons imaging: These photons travel along paths that are confined close to the line of sight between the source and detector (quasi-mimicking X-rays), which reduces image blurring and significantly improves spatial resolution.* ii) Wide-field patterned illumination: A digital micro-mirror device (DMD), made of a 2D array of micro-mirrors that can be individually turned ON or OFF, will be used to generate wide-field patterned illumination on the surface of the tissue. We will leverage recent advances in DMDs technology that produced units that can generate light patterns at very high speed (up to 23 kHz) with high light output (up to 48%), to build a fast and efficient illumination system.* iii) Compressive detection: Light transmitted through the tissue will be projected onto a 2nd DMD (to spatially encode the light intensity), then integrated by a single photodetector. Notice that we will be using a single-pixel camera to generate 3D images without scanning or multiplexing.*2) We will develop an image reconstruction software based on accurate Monte Carlo modeling of early-photons propagation in tissue.*3) The spatial resolution of the scanner will be quantified using tissue-mimicking phantoms with spatially-resolved features.*4) The dynamic imaging capability of the system will be tested in an animal model of localized ischemia.*Impact*The research program detailed in this proposal will lead to the development of a DOT scanner capable of fast 3D imaging of thick tissue (up to 60-mm thickness) with millimeter resolution. Such a scanner will enable dynamic imaging of molecular tracers to develop methods for i) small animal molecular imaging, ii) monitoring treatment response in inflammatory arthritis, and iii) predicting response to chemotherapy in breast cancer.*