Grant: Engage Grants Program
University of Calgary
$25,000.00
Application of high-frequency alternating-current principles to develop practical induction well bore heaters for in-situ thermal ground remediation
FY 2019-20
Summary
The Government of Canada lists 23,670 sites Canada-wide where contaminants in soil and water have been remediated or are in need of remediation. In Alberta alone, roughly 6.48 million liters of hydrocarbon liquids have leaked onto soil and water between 1990 and 2012. A few electrical and chemical methods are currently in use to remediate the contaminated soil in the vicinity of these hydrocarbon leaks. Electrical methods involve electro-thermal or electrical heating of contaminated soil and water using large electrodes inserted into the ground, which are driven using a large AC power source on the surface. Electro-thermal heating offers the advantage of desorbing hydrocarbon contaminants in soil without adding secondary chemical pollutants. Challenges with electro-thermal heating of contaminated soil come from power losses and limited heat penetration over distance in less permeable soil types. More recently inductive heaters fitted with coils that produce magnetic fields at AC frequencies much higher than 60 Hz to induce heat in the walls of surrounding steel wellbore pipe casings have also been developed by the industry partner (McMillan-McGee Corp.) for heating soil more effectively. Unlike conventional 60 Hz electrodes, characterizing and mitigating these losses at high frequencies is even more challenging since losses are expected to be due to not just coil conductor losses but also due to the interaction of the coil's electric and magnetic fields with the surrounding well-bore pipe, and to a lesser extent on the surrounding ground formation. For electro-thermal applications, some of these losses get converted to heat and assist with the electrical heating process but others inhibit electrical power transfer and transmission along the coils. McMillan-McGee and the University of Calgary have formed a research collaboration to study and characterize these high frequency electrical losses in McMillan-McGee's new higher frequency Electro-thermal inductive heaters. With power levels of between 10-80 kW sent down hole into the heaters during the electro-thermal remediation process characterizing and minimizing these losses becomes important for quicker decontamination of soil and saving more energy.
Program
Engage Grants Program
Recipient
Location
Alberta, Canada
Recipient Type
Academia
Type
Grant
Source
NSERC's Awards Data
As published
Application id
543771-2019
Name nom
Vyas, Rushi
Department département
Electrical and Computer Engineering
Organization id
11
Institution établissement
University of Calgary
Province en
Alberta
Province fr
Alberta
Country en
CANADA
Country fr
CANADA
Fiscal year exercice financier
2019
Competition year année de concours
2019
Award amount
25000
Program id
EGP
Program name en
Engage Grants Program
Program name fr
Programme de subventions d'engagement partenariat
Group en
RESEARCH PARTNERSHIPS
Group fr
PARTENARIATS DE RECHERCHE
Committee code
1555
Committee name en
Prairie Internal Decision Committee
Committee name fr
Comité de décision interne pour les Prairies
Area of application code
400
Area of application group en
Environment
Area of application group fr
Environnement
Area of application en
Environment
Area of application fr
Environnement
Research subject code
2500
Research subject group en
Electrical and electronic engineering
Research subject group fr
Génie électrique et électronique
Research subject en
Electrical and electronic engineering
Research subject fr
Génie électrique et électronique
Installment
inst:1 - 1
Partie
1
Nb partie
1
Application title
Application of high-frequency alternating-current principles to develop practical induction well bore heaters for in-situ thermal ground remediation
Keyword
NSERC
Application summary
The Government of Canada lists 23,670 sites Canada-wide where contaminants in soil and water have been remediated or are in need of remediation. In Alberta alone, roughly 6.48 million liters of hydrocarbon liquids have leaked onto soil and water between 1990 and 2012. A few electrical and chemical methods are currently in use to remediate the contaminated soil in the vicinity of these hydrocarbon leaks. Electrical methods involve electro-thermal or electrical heating of contaminated soil and water using large electrodes inserted into the ground, which are driven using a large AC power source on the surface. Electro-thermal heating offers the advantage of desorbing hydrocarbon contaminants in soil without adding secondary chemical pollutants. Challenges with electro-thermal heating of contaminated soil come from power losses and limited heat penetration over distance in less permeable soil types. More recently inductive heaters fitted with coils that produce magnetic fields at AC frequencies much higher than 60 Hz to induce heat in the walls of surrounding steel wellbore pipe casings have also been developed by the industry partner (McMillan-McGee Corp.) for heating soil more effectively. Unlike conventional 60 Hz electrodes, characterizing and mitigating these losses at high frequencies is even more challenging since losses are expected to be due to not just coil conductor losses but also due to the interaction of the coil's electric and magnetic fields with the surrounding well-bore pipe, and to a lesser extent on the surrounding ground formation. For electro-thermal applications, some of these losses get converted to heat and assist with the electrical heating process but others inhibit electrical power transfer and transmission along the coils. McMillan-McGee and the University of Calgary have formed a research collaboration to study and characterize these high frequency electrical losses in McMillan-McGee's new higher frequency Electro-thermal inductive heaters. With power levels of between 10-80 kW sent down hole into the heaters during the electro-thermal remediation process characterizing and minimizing these losses becomes important for quicker decontamination of soil and saving more energy.