Canada Spends Logo

Explore our Budget 2026 analysis

Grant: Discovery Grants Program - Individual

University of Alberta

$28,000.00

Magnetic Resonance Imaging using Radiofrequency Phase Gradients

FY 2018-19

Summary
Medical imaging is a $30B+ industry based on technologies ranging from multi-million dollar hybrid high field MRI-PET systems to the humble X-ray machine, invented over a century ago. Due to technical rather than market reasons there are currently no imaging modalities with both the affordability and accessibility of X-ray and the soft-tissue contrast of MRI. However if a new modality were to fill this significant gap, then novel diagnostic services could be offered to many underserved patient populations, including those in smaller and remote centers. Much of the cost and complexity of MRI systems is associated with the generation of the switched magnetic field gradients needed for image encoding. I am the co-inventor of an alternative MRI encoding principle, known as Transmit Array Spatial Encoding' (TRASE), which functions entirely without this equipment. This method is distinguished from other novel MRI approaches by its potential to generate sub-mm clinical image resolution. Using only the resonant radiofrequency (RF) transmit field, Fourier spatial encoding equivalent to conventional MRI can be achieved. The concept relies upon the production of spatial phase gradients in the RF field and on echo-train pulse sequences. For full 3D imaging, an array of transmit RF coils capable of producing six such phase gradients are needed (+X, -X, +Y, -Y, +Z, -Z). The technique has been very well received, most notably being featured in Research Highlights' in Nature in 2013. Currently, 2D-encoded in vivo MR images of hand and wrist have been obtained at 0.2T using a switched transmit coil array, driven by a single transmitter amplifier. The array produces 4 phase gradient fields, which allows the encoding of two orthogonal spatial axes. Full 3D encoding using six fields has been demonstrated in phantom experiments only. The first major objective is to develop RF array technology capable of the acquisition of 3D clinical-level resolution images in vivo. This is dependent upon improving coil circuit efficiency so that the generation of RF pulses as short as 100 microseconds becomes possible. The second major objective is to investigate and implement reduced encoding schemes enabling practical examination times for 3D sequences. TRASE is inherently slower than conventional MRI, but by taking advantage of the very extensive literature on MRI scan acceleration this can be overcome. The three proposed approaches, implemented either individually or in combination, are partial Fourier, parallel imaging, and sparse encoding. Subsidiary to this will be developing a deeper understanding of the mechanism giving rise to image artifacts. The longer term program aim is to provide the scientific and technical grounding need to develop a new class of medical imaging device. Future aims include the study of image contrasts, clinically-specific protocols and integration with novel low-cost magnets.
Program
Discovery Grants Program - Individual
Location
Alberta, Canada
Recipient Type
Academia
Type
Grant
Source
NSERC's Awards Data

As published

Application id
RGPIN-2016-05183
Name nom
Sharp, Jonathan
Department département
Oncology
Organization id
9
Institution établissement
University of Alberta
Province en
Alberta
Province fr
Alberta
Country en
CANADA
Country fr
CANADA
Fiscal year exercice financier
2018
Competition year année de concours
2016
Award amount
28000
Program id
RGPIN
Program name en
Discovery Grants Program - Individual
Program name fr
Programme de subventions à la découverte - individuelles
Group en
Discovery grants programs
Group fr
Programmes de subventions à la découverte
Committee code
1505
Committee name en
Physics
Committee name fr
Physique
Area of application code
518
Area of application group en
Manufacturing processes and products
Area of application group fr
Procédés et produits industriels
Area of application en
Medical equipment and apparatus
Area of application fr
Appareils et instruments médicaux
Research subject code
1901
Research subject group en
Biomedical engineering
Research subject group fr
Génie biomédical
Research subject en
Biomedical technology
Research subject fr
Technologie biomédicale
Partie
3
Nb partie
5
Application title
Magnetic Resonance Imaging using Radiofrequency Phase Gradients
Keyword
NSERC
Application summary
Medical imaging is a $30B+ industry based on technologies ranging from multi-million dollar hybrid high field MRI-PET systems to the humble X-ray machine, invented over a century ago. Due to technical rather than market reasons there are currently no imaging modalities with both the affordability and accessibility of X-ray and the soft-tissue contrast of MRI. However if a new modality were to fill this significant gap, then novel diagnostic services could be offered to many underserved patient populations, including those in smaller and remote centers. Much of the cost and complexity of MRI systems is associated with the generation of the switched magnetic field gradients needed for image encoding. I am the co-inventor of an alternative MRI encoding principle, known as Transmit Array Spatial Encoding' (TRASE), which functions entirely without this equipment. This method is distinguished from other novel MRI approaches by its potential to generate sub-mm clinical image resolution. Using only the resonant radiofrequency (RF) transmit field, Fourier spatial encoding equivalent to conventional MRI can be achieved. The concept relies upon the production of spatial phase gradients in the RF field and on echo-train pulse sequences. For full 3D imaging, an array of transmit RF coils capable of producing six such phase gradients are needed (+X, -X, +Y, -Y, +Z, -Z). The technique has been very well received, most notably being featured in Research Highlights' in Nature in 2013. Currently, 2D-encoded in vivo MR images of hand and wrist have been obtained at 0.2T using a switched transmit coil array, driven by a single transmitter amplifier. The array produces 4 phase gradient fields, which allows the encoding of two orthogonal spatial axes. Full 3D encoding using six fields has been demonstrated in phantom experiments only. The first major objective is to develop RF array technology capable of the acquisition of 3D clinical-level resolution images in vivo. This is dependent upon improving coil circuit efficiency so that the generation of RF pulses as short as 100 microseconds becomes possible. The second major objective is to investigate and implement reduced encoding schemes enabling practical examination times for 3D sequences. TRASE is inherently slower than conventional MRI, but by taking advantage of the very extensive literature on MRI scan acceleration this can be overcome. The three proposed approaches, implemented either individually or in combination, are partial Fourier, parallel imaging, and sparse encoding. Subsidiary to this will be developing a deeper understanding of the mechanism giving rise to image artifacts. The longer term program aim is to provide the scientific and technical grounding need to develop a new class of medical imaging device. Future aims include the study of image contrasts, clinically-specific protocols and integration with novel low-cost magnets.