Grant: Engage Grants Program
University of Toronto
$25,000.00
Using interface shape as an indicator of surface quality of microarray plates
FY 2012-13
Summary
Contact angle measurements does not provide an accurate prediction of the shape of the droplet for cases with
moderate Bond numbers typical of these microarray plates. However, the ratio of the contact radius to the
height of the droplet better characterizes the surface of the microarray plate and predicts the shape of the
droplets allowing fast determination of droplet quality. Predicting the interface shape using the ratio of the
contact radius to the height decreased the error in the predicted interface shape and droplet height by roughly a
factor of three when predictions were made using local measurement and globally averaged characteristics. For
moderate Bond numbers, it would be advantageous to use a characteristic value for the radius to height ratio as
all the droplets on a microarray plate could be characterized from one or more overhead images that optically
measure the radius of multiple droplets. Although this method will result in a similar error as local
measurements of both the radius and the droplet height, information about the measured contact angle will be
lost which could provide information on the variability of the surface characteristic of a microarray plate and
may be important in some applications. It is necessary to develop technique for rapid quantification of droplet
uniformity for different surface treatments and qualities. By using a characteristic value of the radius to height
ratio, all droplets on a microarray plate could be quickly characterized from a single overhead image where the
radius of multiple droplets could be determined. Although this method will result in more rapid results with
similar errors of local measurements of the radius and the droplet height, information regarding the local
measured contact angle is lost.
Program
Engage Grants Program
Recipient
Location
Ontario, Canada
Recipient Type
Academia
Type
Grant
Source
NSERC's Awards Data
As published
Application id
434827-2012
Name nom
Sullivan, Pierre
Department département
Mechanical and Industrial Engineering
Organization id
31
Institution établissement
University of Toronto
Province en
Ontario
Province fr
Ontario
Country en
CANADA
Country fr
CANADA
Fiscal year exercice financier
2012
Competition year année de concours
2012
Award amount
25000
Program id
EGP
Program name en
Engage Grants Program
Program name fr
Programme de subventions d'engagement partenariat
Group en
Research partnerships programs
Group fr
Programmes de partenariat
Committee code
1553
Committee name en
Ontario Internal Decision Committee
Committee name fr
Comité de décision interne pour l'Ontario
Area of application code
1102
Area of application group en
Health, education and social services
Area of application group fr
Santé publique, éducation et services sociaux
Area of application en
Biomedical engineering
Area of application fr
Génie biomédical
Research subject code
1902
Research subject group en
Biomedical engineering
Research subject group fr
Génie biomédical
Research subject en
Biomedical materials
Research subject fr
Matériaux biomédicaux
Partie
1
Nb partie
1
Application title
Using interface shape as an indicator of surface quality of microarray plates
Keyword
NSERC
Application summary
Contact angle measurements does not provide an accurate prediction of the shape of the droplet for cases with
moderate Bond numbers typical of these microarray plates. However, the ratio of the contact radius to the
height of the droplet better characterizes the surface of the microarray plate and predicts the shape of the
droplets allowing fast determination of droplet quality. Predicting the interface shape using the ratio of the
contact radius to the height decreased the error in the predicted interface shape and droplet height by roughly a
factor of three when predictions were made using local measurement and globally averaged characteristics. For
moderate Bond numbers, it would be advantageous to use a characteristic value for the radius to height ratio as
all the droplets on a microarray plate could be characterized from one or more overhead images that optically
measure the radius of multiple droplets. Although this method will result in a similar error as local
measurements of both the radius and the droplet height, information about the measured contact angle will be
lost which could provide information on the variability of the surface characteristic of a microarray plate and
may be important in some applications. It is necessary to develop technique for rapid quantification of droplet
uniformity for different surface treatments and qualities. By using a characteristic value of the radius to height
ratio, all droplets on a microarray plate could be quickly characterized from a single overhead image where the
radius of multiple droplets could be determined. Although this method will result in more rapid results with
similar errors of local measurements of the radius and the droplet height, information regarding the local
measured contact angle is lost.