Canada Spends Logo

Explore our Budget 2026 analysis

Grant: Engage Grants Program

Concordia University

$24,984.00

Hygrothermal performance of a building envelope system using structural insulated panels (SIP) subjected to Nunavut climatic conditions

FY 2010-11

Summary
The research planned in this proposal aims to characterize and extend the performance of a manufactured building system developed by the Kott group in Ottawa for remote northern regions; 142 homes have been delivered to the Nunavut Housing Corporation and are currently being built. Northern regions face a series of unique design challenges including high cost and difficulty in transporting construction materials, the harshness of the climate, remoteness of the communities and high costs of energy. In the harsh winters, wall, roof, and floor components are subjected to large differences in indoor and outdoor temperatures and humidity, which can lead to deterioration and/or failure of these components requiring costly repairs and maintenance and higher energy bills, and likely to discomfort and possibly health symptoms to the occupants. The research being carried out as part of this proposal utilizes an inverted test hut made from these wall, floor and roof panels, where the inside will be cooled to Arctic outdoor winter conditions and the outside left to indoor laboratory conditions representing the indoor environment of the housing unit. By this method, it is possible to examine the effects of these extreme differences on the wall panels using a relatively simple and quick test. The wall panels are instrumented both at the connections between panels and through the panels themselves. The temperatures and moisture contents are monitored continuously as the hut is cooled and comparisons made between both sections. Ultimately, the performance of the overall wall system can then be determined including the effects of the connections. With the results from this experiment, weak points in the system can be identified and recommendations made to improve the design for future projects or modifications proposed to improve the performance of the houses already under construction. This type research is useful in characterizing and extending the performance of the houses. Through this project the KOTT housing system will benefit from the advanced expertise and facilities developed at Concordia in housing over the past decades.
Program
Engage Grants Program
Location
Quebec, Canada
Recipient Type
Academia
Type
Grant
Source
NSERC's Awards Data

As published

Application id
411678-2010
Name nom
Fazio, Paul
Department département
Building, Civil and Environmental Engineering
Organization id
70
Institution établissement
Concordia University
Province en
Québec
Province fr
Québec
Country en
CANADA
Country fr
CANADA
Fiscal year exercice financier
2010
Competition year année de concours
2010
Award amount
24984
Program id
EGP
Program name en
Engage Grants Program
Program name fr
Programme de subventions d'engagement partenariat
Group en
Research partnerships programs
Group fr
Programmes de partenariat
Committee code
1552
Committee name en
Quebec Internal Decision Committee
Committee name fr
Comité de décision interne pour le Québec
Area of application code
500
Area of application group en
Manufacturing processes and products
Area of application group fr
Procédés et produits industriels
Area of application en
Manufacturing processes and products
Area of application fr
Procédés et produits industriels
Research subject code
1000
Research subject group en
Civil engineering
Research subject group fr
Génie civil
Research subject en
Civil engineering
Research subject fr
Génie civil
Partie
1
Nb partie
1
Application title
Hygrothermal performance of a building envelope system using structural insulated panels (SIP) subjected to Nunavut climatic conditions
Keyword
NSERC
Application summary
The research planned in this proposal aims to characterize and extend the performance of a manufactured building system developed by the Kott group in Ottawa for remote northern regions; 142 homes have been delivered to the Nunavut Housing Corporation and are currently being built. Northern regions face a series of unique design challenges including high cost and difficulty in transporting construction materials, the harshness of the climate, remoteness of the communities and high costs of energy. In the harsh winters, wall, roof, and floor components are subjected to large differences in indoor and outdoor temperatures and humidity, which can lead to deterioration and/or failure of these components requiring costly repairs and maintenance and higher energy bills, and likely to discomfort and possibly health symptoms to the occupants. The research being carried out as part of this proposal utilizes an inverted test hut made from these wall, floor and roof panels, where the inside will be cooled to Arctic outdoor winter conditions and the outside left to indoor laboratory conditions representing the indoor environment of the housing unit. By this method, it is possible to examine the effects of these extreme differences on the wall panels using a relatively simple and quick test. The wall panels are instrumented both at the connections between panels and through the panels themselves. The temperatures and moisture contents are monitored continuously as the hut is cooled and comparisons made between both sections. Ultimately, the performance of the overall wall system can then be determined including the effects of the connections. With the results from this experiment, weak points in the system can be identified and recommendations made to improve the design for future projects or modifications proposed to improve the performance of the houses already under construction. This type research is useful in characterizing and extending the performance of the houses. Through this project the KOTT housing system will benefit from the advanced expertise and facilities developed at Concordia in housing over the past decades.
Concordia University - $24,984 Grant (2010-11) | Canada Spends