Grant: Discovery Grants Program - Individual
University of Toronto
$24,000.00
Exploiting the Magnetic Properties of Blood
FY 2017-18
Summary
Magnetic Resonance Imaging (MRI) generates exquisite images of soft tissues and has become a major imaging modality, competing with x-ray and ultrasound. MRI excels at taking pictures of blood because in some forms, blood is slightly magnetic. When blood starts decomposing, it turns into Methemoglobin (metHb). MetHb reacts to external magnetic fields and, if we tune the MRI parameters correctly, we can easily detect MetHb with MRI. MetHb is known to negatively affect cell membranes, it oxidizes cholesterol, it creates an inflammatory response, but most importantly, in certain environments, it generates more MetHb. Thus, this MetHb is associated with negative outcomes, both in burns, as well as bleeds. Furthermore, MetHb in the blood vessels that feed the brain seems to be a major risk factor for future stroke. Methods of detecting and characterizing MetHb would be very useful for both staging disease and prognosticating results. In my proposed research program, we will develop better methods of not just detecting MetHb, but we will validate methods of quantitatively measuring MetHb concentrations. We hypothesize that this will allow us to more accurately determine tissue prognosis in both burns and bleeds. Further, our research program will look at implementing MetHb detection techniques in conjunction with a local company developing low field MRI. We will design hardware as well as reprogram the pulse sequences to accurately detect methemoglobin in phantom models as well as surgical specimens.This new hardware may enable the deployment of MetHb detection on a larger scale than is available by high field MRI. However, the number of people actually getting an MRI to evaluate for risk of stroke is very small in Canada, and even smaller world wide. Thus, the final stream of our research program will develop techniques to detect methemoglobin outside a traditional MR environment. We will develop small, hand held systems that wont be focused on imaging, but only detection of this methemoglobin signal. These three streams of proposed research build on each other; the first looking only at pulse sequencing, the second building hardware, and the third building magnetic field systems. This proposed research program covers the entire breadth of technology development in MR imaging, with significant cross fertilization between research streams and research projects.
Program
Discovery Grants Program - Individual
Recipient
Location
Ontario, Canada
Recipient Type
Academia
Type
Grant
Source
NSERC's Awards Data
As published
Application id
RGPIN-2016-06217
Name nom
Leung, General
Department département
Medical Imaging - Medical Imaging
Organization id
31
Institution établissement
University of Toronto
Province en
Ontario
Province fr
Ontario
Country en
CANADA
Country fr
CANADA
Fiscal year exercice financier
2017
Competition year année de concours
2016
Award amount
24000
Program id
RGPIN
Program name en
Discovery Grants Program - Individual
Program name fr
Programme de subventions à la découverte - individuelles
Group en
Discovery grants programs
Group fr
Programmes de subventions à la découverte
Committee code
1505
Committee name en
Physics
Committee name fr
Physique
Area of application code
1201
Area of application group en
Advancement of knowledge
Area of application group fr
Avancement des connaissances
Area of application en
Life sciences (including biotechnology)
Area of application fr
Sciences de la vie (y compris biotechnologie)
Research subject code
2514
Research subject group en
Electrical and electronic engineering
Research subject group fr
Génie électrique et électronique
Research subject en
Digital signal processing
Research subject fr
Traitement des signaux numériques
Partie
2
Nb partie
5
Application title
Exploiting the Magnetic Properties of Blood
Keyword
NSERC
Application summary
Magnetic Resonance Imaging (MRI) generates exquisite images of soft tissues and has become a major imaging modality, competing with x-ray and ultrasound. MRI excels at taking pictures of blood because in some forms, blood is slightly magnetic. When blood starts decomposing, it turns into Methemoglobin (metHb). MetHb reacts to external magnetic fields and, if we tune the MRI parameters correctly, we can easily detect MetHb with MRI. MetHb is known to negatively affect cell membranes, it oxidizes cholesterol, it creates an inflammatory response, but most importantly, in certain environments, it generates more MetHb. Thus, this MetHb is associated with negative outcomes, both in burns, as well as bleeds. Furthermore, MetHb in the blood vessels that feed the brain seems to be a major risk factor for future stroke. Methods of detecting and characterizing MetHb would be very useful for both staging disease and prognosticating results. In my proposed research program, we will develop better methods of not just detecting MetHb, but we will validate methods of quantitatively measuring MetHb concentrations. We hypothesize that this will allow us to more accurately determine tissue prognosis in both burns and bleeds. Further, our research program will look at implementing MetHb detection techniques in conjunction with a local company developing low field MRI. We will design hardware as well as reprogram the pulse sequences to accurately detect methemoglobin in phantom models as well as surgical specimens.This new hardware may enable the deployment of MetHb detection on a larger scale than is available by high field MRI. However, the number of people actually getting an MRI to evaluate for risk of stroke is very small in Canada, and even smaller world wide. Thus, the final stream of our research program will develop techniques to detect methemoglobin outside a traditional MR environment. We will develop small, hand held systems that wont be focused on imaging, but only detection of this methemoglobin signal. These three streams of proposed research build on each other; the first looking only at pulse sequencing, the second building hardware, and the third building magnetic field systems. This proposed research program covers the entire breadth of technology development in MR imaging, with significant cross fertilization between research streams and research projects.