Canada Spends Logo

Explore our Budget 2026 analysis

Grant: Engage Grants Program

Concordia University

$24,979.00

Optimization and validation of a new multi-sensor optical based pressure wire for cardiovascular diagnostics

FY 2012-13

Summary
In this proposed project, we will contribute towards the optimization and validation of a new multi-sensor fiber-optic based pressure wire with applications to cardiovascular disease diagnosis. We will use experimental techniques to determine the optimal design parameters for aortic stenosis severity clinical evaluation using the new pressure wire. This project, will significantly contribute to HemoDynamix Medical Devices efforts to overcome the technical challenges that are currently preventing the application of their recently developed fiber optical based ultra-miniature pressure wire to cardiovascular diagnostic. In this proposed research, the well validated pulse duplicator existing in Dr. Kadem's Lab will be used. It will be modified to includes models of supra-valvular and sub-valvular stenoses, with different severities. Several severities of aortic stenoses will be investigated ranging from 0.6 to 1.5 cm^2 in terms of effective orifice areas. This is to simulate patients with moderate to severe aortic stenosis. For all tests, the recordings obtained using the new multi-sensor pressure wire will be compared with those obtained by Doppler echocardiographic recordings and using a standard single-sensor catheter. The results will allow the determination of the optimal working parameters for cardiovascular measurements using the new pressure wire (optimal distance between the sensors, frequency response when the probe is fluid-filled or not). Furthermore, a standalone code for data acquisition, analysis and display of cardiovascular signals and parameters will be developed and transferred to the company. This project is unique in Canada and has the potential to give Canadian industry leading role in the exponentially growing market of medical devices.
Program
Engage Grants Program
Location
Quebec, Canada
Recipient Type
Academia
Type
Grant
Source
NSERC's Awards Data

As published

Application id
445795-2012
Name nom
Kadem, Lyes
Department département
Mechanical and Industrial Engineering
Organization id
70
Institution établissement
Concordia University
Province en
Québec
Province fr
Québec
Country en
CANADA
Country fr
CANADA
Fiscal year exercice financier
2012
Competition year année de concours
2012
Award amount
24979
Program id
EGP
Program name en
Engage Grants Program
Program name fr
Programme de subventions d'engagement partenariat
Group en
Research partnerships programs
Group fr
Programmes de partenariat
Committee code
1552
Committee name en
Quebec Internal Decision Committee
Committee name fr
Comité de décision interne pour le Québec
Area of application code
518
Area of application group en
Manufacturing processes and products
Area of application group fr
Procédés et produits industriels
Area of application en
Medical equipment and apparatus
Area of application fr
Appareils et instruments médicaux
Research subject code
1900
Research subject group en
Biomedical engineering
Research subject group fr
Génie biomédical
Research subject en
Biomedical engineering
Research subject fr
Génie biomédical
Partie
1
Nb partie
1
Application title
Optimization and validation of a new multi-sensor optical based pressure wire for cardiovascular diagnostics
Keyword
NSERC
Application summary
In this proposed project, we will contribute towards the optimization and validation of a new multi-sensor fiber-optic based pressure wire with applications to cardiovascular disease diagnosis. We will use experimental techniques to determine the optimal design parameters for aortic stenosis severity clinical evaluation using the new pressure wire. This project, will significantly contribute to HemoDynamix Medical Devices efforts to overcome the technical challenges that are currently preventing the application of their recently developed fiber optical based ultra-miniature pressure wire to cardiovascular diagnostic. In this proposed research, the well validated pulse duplicator existing in Dr. Kadem's Lab will be used. It will be modified to includes models of supra-valvular and sub-valvular stenoses, with different severities. Several severities of aortic stenoses will be investigated ranging from 0.6 to 1.5 cm^2 in terms of effective orifice areas. This is to simulate patients with moderate to severe aortic stenosis. For all tests, the recordings obtained using the new multi-sensor pressure wire will be compared with those obtained by Doppler echocardiographic recordings and using a standard single-sensor catheter. The results will allow the determination of the optimal working parameters for cardiovascular measurements using the new pressure wire (optimal distance between the sensors, frequency response when the probe is fluid-filled or not). Furthermore, a standalone code for data acquisition, analysis and display of cardiovascular signals and parameters will be developed and transferred to the company. This project is unique in Canada and has the potential to give Canadian industry leading role in the exponentially growing market of medical devices.
Concordia University - $24,979 Grant (2012-13) | Canada Spends