Canada Spends Logo

Explore our Budget 2026 analysis

Grant: Engage Grants Program

McGill University

$25,000.00

Organic Field Effect Transistors as Novel Radiation Detectors

FY 2013-14

Summary
Best Medical Canada (BMC) is a leading international company specializing in production of radiation detectors for medical and space applications. The currently used technology is based on measuring the electrical response of silicon-based MOSFET transistors to radiation exposure. The company is actively looking at various ways to diversify its line of products and investigates various new technologies to achieve this purpose.In this respect, organic field effect transistors (OFET) could potentially offer several key advantages for radiation detection, including similar absorption profile to that of organic tissue, flexibility, biocompatibility, etc. However, BMC does not have the expertise necessary to fabricate or study OFET devices. The objective of this proposal is to utilize the expertise of Prof. Perepichka (who has been involved in studies of OFET materials and devices over the last 8 years) to investigate the possibility to apply OFET devices in radiation dosimetry.Specifically, we will focus on modifying the structure of OFET devices (currently fabricated in Perepichka's lab) to make them usable in standard radiation detectors systems produced by BMC. We will measure the response of OFET to radiation fields of wide range of energy (X-ray, gamma ray and electron radiation) and intensity. Our expectation is that using purely organic materials will improve water equivalency of such OFET detectors, making them more suitable for medical applications. This work will lay the foundation for the actual design, construction and evaluation of OFET radiation dosimetry systems with improved characteristics.
Program
Engage Grants Program
Location
Quebec, Canada
Recipient Type
Academia
Type
Grant
Source
NSERC's Awards Data

As published

Application id
447053-2013
Name nom
Perepichka, Dmitrii
Department département
Chemistry
Organization id
61
Institution établissement
McGill University
Province en
Québec
Province fr
Québec
Country en
CANADA
Country fr
CANADA
Fiscal year exercice financier
2013
Competition year année de concours
2013
Award amount
25000
Program id
EGP
Program name en
Engage Grants Program
Program name fr
Programme de subventions d'engagement partenariat
Group en
Research partnerships programs
Group fr
Programmes de partenariat
Committee code
1553
Committee name en
Ontario Internal Decision Committee
Committee name fr
Comité de décision interne pour l'Ontario
Area of application code
1211
Area of application group en
Advancement of knowledge
Area of application group fr
Avancement des connaissances
Area of application en
Medical and health sciences
Area of application fr
Sciences médicales et de la santé
Research subject code
2009
Research subject group en
Materials science and technology
Research subject group fr
Science et technologie des matériaux
Research subject en
Semiconductors
Research subject fr
Semi-conducteurs
Partie
1
Nb partie
1
Application title
Organic Field Effect Transistors as Novel Radiation Detectors
Keyword
NSERC
Application summary
Best Medical Canada (BMC) is a leading international company specializing in production of radiation detectors for medical and space applications. The currently used technology is based on measuring the electrical response of silicon-based MOSFET transistors to radiation exposure. The company is actively looking at various ways to diversify its line of products and investigates various new technologies to achieve this purpose.In this respect, organic field effect transistors (OFET) could potentially offer several key advantages for radiation detection, including similar absorption profile to that of organic tissue, flexibility, biocompatibility, etc. However, BMC does not have the expertise necessary to fabricate or study OFET devices. The objective of this proposal is to utilize the expertise of Prof. Perepichka (who has been involved in studies of OFET materials and devices over the last 8 years) to investigate the possibility to apply OFET devices in radiation dosimetry.Specifically, we will focus on modifying the structure of OFET devices (currently fabricated in Perepichka's lab) to make them usable in standard radiation detectors systems produced by BMC. We will measure the response of OFET to radiation fields of wide range of energy (X-ray, gamma ray and electron radiation) and intensity. Our expectation is that using purely organic materials will improve water equivalency of such OFET detectors, making them more suitable for medical applications. This work will lay the foundation for the actual design, construction and evaluation of OFET radiation dosimetry systems with improved characteristics.