Grant: Discovery Grants Program - Individual
University of New Brunswick
$25,000.00
Improving the Performance, Robustness and Reliability of Myoelectric Control
FY 2016-17
Summary
The loss or congenital absence of a limb is a major disability that can have considerable physical and psychological impact on the life of an amputee. It is estimated that there are more than 3 million upper limb amputees globally, with the rate of incidence growing steadily. The loss of an upper limb, in particular, can greatly affect an individual's level of independence and self-esteem, as well as lead to overuse injuries of the neck, shoulders and back. Although upper limb prostheses have evolved considerably, the method of controlling them has changed little since the 1960s. These devices use the electromyogram (electrical signals generated while contracting muscles of the residual limb) to determine the intent of the user. Termed myoelectric control, this approach is functional and non-invasive, but commercially available systems provide limited control and can be unintuitive.
Recently, significant advances in myoelectric control have been shown in the literature. Pattern-based approaches have shown the ability to control more motions, more intuitively, but robustness remains a concern. Our recent work has highlighted possibilities for greatly improving the reliability of these systems through algorithmic improvements and better understanding of confounding factors. Furthermore, we have identified flaws in the assumptions that form the basis of the standard design approach. The objective of this research is to apply these findings, using novel approaches in signal processing and system design, and novel pressure sensing technology to improve the control, performance and reliability of upper limb prosthetics, and human-machine interfaces in general.
Program
Discovery Grants Program - Individual
Recipient
Location
New Brunswick, Canada
Recipient Type
Academia
Type
Grant
Source
NSERC's Awards Data
As published
Application id
RGPIN-2014-04920
Name nom
Scheme, Erik
Department département
Electrical and Computer Engineering
Organization id
75
Institution établissement
University of New Brunswick
Province en
New Brunswick
Province fr
Nouveau-Brunswick
Country en
CANADA
Country fr
CANADA
Fiscal year exercice financier
2016
Competition year année de concours
2014
Award amount
25000
Program id
RGPIN
Program name en
Discovery Grants Program - Individual
Program name fr
Programme de subventions à la découverte - individuelles
Group en
Discovery grants programs
Group fr
Programmes de subventions à la découverte
Committee code
1510
Committee name en
Electrical and Computer Engineering
Committee name fr
Génie électrique et informatique
Area of application code
1102
Area of application group en
Health, education and social services
Area of application group fr
Santé publique, éducation et services sociaux
Area of application en
Biomedical engineering
Area of application fr
Génie biomédical
Research subject code
1900
Research subject group en
Biomedical engineering
Research subject group fr
Génie biomédical
Research subject en
Biomedical engineering
Research subject fr
Génie biomédical
Partie
3
Nb partie
5
Application title
Improving the Performance, Robustness and Reliability of Myoelectric Control
Keyword
NSERC
Application summary
The loss or congenital absence of a limb is a major disability that can have considerable physical and psychological impact on the life of an amputee. It is estimated that there are more than 3 million upper limb amputees globally, with the rate of incidence growing steadily. The loss of an upper limb, in particular, can greatly affect an individual's level of independence and self-esteem, as well as lead to overuse injuries of the neck, shoulders and back. Although upper limb prostheses have evolved considerably, the method of controlling them has changed little since the 1960s. These devices use the electromyogram (electrical signals generated while contracting muscles of the residual limb) to determine the intent of the user. Termed myoelectric control, this approach is functional and non-invasive, but commercially available systems provide limited control and can be unintuitive.
Recently, significant advances in myoelectric control have been shown in the literature. Pattern-based approaches have shown the ability to control more motions, more intuitively, but robustness remains a concern. Our recent work has highlighted possibilities for greatly improving the reliability of these systems through algorithmic improvements and better understanding of confounding factors. Furthermore, we have identified flaws in the assumptions that form the basis of the standard design approach. The objective of this research is to apply these findings, using novel approaches in signal processing and system design, and novel pressure sensing technology to improve the control, performance and reliability of upper limb prosthetics, and human-machine interfaces in general.