Canada Spends Logo

Explore our Budget 2026 analysis

Grant: Engage Grants Program

Université du Québec à Chicoutimi

$25,000.00

Calibrating and testing a sensor with triple ability to measure moisture, vibration and temperature

FY 2018-19

Summary
Power transformers are important and one of the costliest equipment used in the transmission and distribution*of the electric energy. Despite great progresses in their design in recent years, the Achilles heel still remains the*insulation system. When power transformers fail, the fault can be traced usually to defective insulation.*Unexpected failures cause major disturbances to operating systems, resulting in unscheduled outages and*power delivery problems. Extreme reliability is demanded of electric power distribution as when failures occur*they inevitably lead to high repair costs, long downtime and possible personnel safety risks. By accurately*monitoring the condition of the insulation (moisture ingress, temperature, vibration, etc.) many types of faults*can be discovered before they become serious failures and outages.*Some of the research and development accomplishments by QPS during the past years have resulted in the*development of a Phase Shifted Gratings recoated sensor with multilayers of polyimide films. This fiber optic*sensor is designed to help plant owners monitor moisture, vibration and temperature inside oil filled*transformers. The proposed research aims at analysing field test data records and accurately calibrating the*sensor. The knowledge and technology that will develop from the proposed research are of great importance to*both Canadian manufacturing and power utility industries. The sensor has high potential for on-line monitoring*of transformers. Using the improved sensor will provide solutions to transformers integrity in smart grids,*assuring the system reliability.
Program
Engage Grants Program
Location
Quebec, Canada
Recipient Type
Academia
Type
Grant
Source
NSERC's Awards Data

As published

Application id
530988-2018
Name nom
Fofana, Issouf
Department département
Sciences appliquées
Organization id
52
Institution établissement
Université du Québec à Chicoutimi
Province en
Québec
Province fr
Québec
Country en
CANADA
Country fr
CANADA
Fiscal year exercice financier
2018
Competition year année de concours
2018
Award amount
25000
Program id
EGP
Program name en
Engage Grants Program
Program name fr
Programme de subventions d'engagement partenariat
Group en
Research partnerships programs
Group fr
Programmes de partenariat
Committee code
1552
Committee name en
Quebec Internal Decision Committee
Committee name fr
Comité de décision interne pour le Québec
Area of application code
304
Area of application group en
Energy resources
Area of application group fr
Ressources d'énergie
Area of application en
Electrical energy
Area of application fr
Énergie électrique
Research subject code
2500
Research subject group en
Electrical and electronic engineering
Research subject group fr
Génie électrique et électronique
Research subject en
Electrical and electronic engineering
Research subject fr
Génie électrique et électronique
Partie
1
Nb partie
1
Application title
Calibrating and testing a sensor with triple ability to measure moisture, vibration and temperature
Keyword
NSERC
Application summary
Power transformers are important and one of the costliest equipment used in the transmission and distribution*of the electric energy. Despite great progresses in their design in recent years, the Achilles heel still remains the*insulation system. When power transformers fail, the fault can be traced usually to defective insulation.*Unexpected failures cause major disturbances to operating systems, resulting in unscheduled outages and*power delivery problems. Extreme reliability is demanded of electric power distribution as when failures occur*they inevitably lead to high repair costs, long downtime and possible personnel safety risks. By accurately*monitoring the condition of the insulation (moisture ingress, temperature, vibration, etc.) many types of faults*can be discovered before they become serious failures and outages.*Some of the research and development accomplishments by QPS during the past years have resulted in the*development of a Phase Shifted Gratings recoated sensor with multilayers of polyimide films. This fiber optic*sensor is designed to help plant owners monitor moisture, vibration and temperature inside oil filled*transformers. The proposed research aims at analysing field test data records and accurately calibrating the*sensor. The knowledge and technology that will develop from the proposed research are of great importance to*both Canadian manufacturing and power utility industries. The sensor has high potential for on-line monitoring*of transformers. Using the improved sensor will provide solutions to transformers integrity in smart grids,*assuring the system reliability.
Université du Québec à Chicoutimi - $25,000 Grant (20… | Canada Spends