Grant: Strategic Projects - Group
Simon Fraser University
$113,350.00
An on-site, reconfigurable, multi-sample microfluidic-platform for rapid parallel sample-manipulation
FY 2012-13
Summary
In many fields of importance to Canadians' health and well-being, including environmental monitoring, medical diagnostics, food safety, forensics, and basic biological research, the ability to perform biological and chemical agent detection is of paramount importance. There is a growing need for instruments for fast, accurate, and inexpensive sample manipulation with high-throughput for detection of agents from: 1) many samples; and/or 2) to detect multiple agents in a single sample. Currently, such large scale analysis is performed using slow conventional lab techniques or large table-top systems. Microfluidics technology, which is the manipulation of small liquid volumes in sub-millimetre tubes, offers unparalleled promise for innovation in minimizing instrument size, sample volume, and cost. However, while many successful microfluidic
technologies have been developed, their adoption has thus far been limited due to: the large size (footprint) for multiple parallel fluid channels; technologies requiring large off-chip support such as pneumatics; or strict requirements for fluid manipulation and transfer between devices. The objective of this proposal is to design and fabricate uROAMS: a Microfluidic, Reconfigurable On-site Analyser for Multiplexed Samples, which is a new approach to the high-throughput portability problem accomplished through the merging of electronically controlled functional materials for microfluidics with state-of-the-art field programmable technology. We propose to develop enabling technologies for portable sample analysis that employ a microfluidic multiplexing device based on a reconfigurable microfluidic interconnect. uROAMS has its basis in the applicant's prior research and expertise, with market pull and application-specific expertise from our environmental sector industrial partner. Our unit will be both portable and generic, and will produce a disruptive modular commercial product with applications in multiple market sectors, while producing transferable MEMS technology applicable across multiple disciplines.
Program
Strategic Projects - Group
Recipient
Location
British Columbia, Canada
Recipient Type
Academia
Type
Grant
Source
NSERC's Awards Data
As published
Application id
396755-2010
Name nom
Gray, Bonnie
Department département
Engineering Science, School of
Organization id
5
Institution établissement
Simon Fraser University
Province en
British Columbia
Province fr
Colombie-Britannique
Country en
CANADA
Country fr
CANADA
Fiscal year exercice financier
2012
Competition year année de concours
2010
Award amount
113350
Program id
STPGP
Program name en
Strategic Projects - Group
Program name fr
Projets stratégiques - De groupe
Group en
Research partnerships programs
Group fr
Programmes de partenariat
Committee code
1088
Committee name en
Strategic Projects Selection Panel - Manufacturing - B
Committee name fr
Comité de sélection des projets stratégiques - Fabrication - B
Area of application code
1002
Area of application group en
Northern development
Area of application group fr
Développement du nord
Area of application en
Environment
Area of application fr
Environnement
Research subject code
2523
Research subject group en
Electrical and electronic engineering
Research subject group fr
Génie électrique et électronique
Research subject en
Semiconductor fabrication and packaging
Research subject fr
Fabrication et mise sous enveloppe de semi-conducteurs
Partie
3
Nb partie
3
Application title
An on-site, reconfigurable, multi-sample microfluidic-platform for rapid parallel sample-manipulation
Keyword
NSERC
Application summary
In many fields of importance to Canadians' health and well-being, including environmental monitoring, medical diagnostics, food safety, forensics, and basic biological research, the ability to perform biological and chemical agent detection is of paramount importance. There is a growing need for instruments for fast, accurate, and inexpensive sample manipulation with high-throughput for detection of agents from: 1) many samples; and/or 2) to detect multiple agents in a single sample. Currently, such large scale analysis is performed using slow conventional lab techniques or large table-top systems. Microfluidics technology, which is the manipulation of small liquid volumes in sub-millimetre tubes, offers unparalleled promise for innovation in minimizing instrument size, sample volume, and cost. However, while many successful microfluidic
technologies have been developed, their adoption has thus far been limited due to: the large size (footprint) for multiple parallel fluid channels; technologies requiring large off-chip support such as pneumatics; or strict requirements for fluid manipulation and transfer between devices. The objective of this proposal is to design and fabricate uROAMS: a Microfluidic, Reconfigurable On-site Analyser for Multiplexed Samples, which is a new approach to the high-throughput portability problem accomplished through the merging of electronically controlled functional materials for microfluidics with state-of-the-art field programmable technology. We propose to develop enabling technologies for portable sample analysis that employ a microfluidic multiplexing device based on a reconfigurable microfluidic interconnect. uROAMS has its basis in the applicant's prior research and expertise, with market pull and application-specific expertise from our environmental sector industrial partner. Our unit will be both portable and generic, and will produce a disruptive modular commercial product with applications in multiple market sectors, while producing transferable MEMS technology applicable across multiple disciplines.