Canada Spends Logo

Explore our Budget 2026 analysis

Grant: Discovery Grants Program - Individual

Université de Montréal

$47,000.00

Image processing of medical ultrasound data

FY 2007-08

Summary
The goal of this research program is the development and evaluation of the 3D intravascular ultrasound (IVUS) technology to improve the diagnosis and follow-up of patients with peripheral arterial and coronary artery diseases. Because of its good accuracy and possibility of measuring the atherosclerotic plaque volume, this research should impact the clinical community by providing a robust imaging method for atherosclerotic progression/regression clinical trials based on measurements of plaque volume.      Our specific objectives for the upcoming 5 years are: 1) to develop a fast 3D imaging algorithm for segmenting the plaque volume from IVUS images, 2) to develop a fully automatic method requiring no manual initialization, 3) to validate the accuracy and reproducibility of the image processing algorithm on large clinical data bases acquired from patients with femoropopliteal and coronary artery diseases, and 4) to adapt the 3D segmentation method to process the higher-resolution radio-frequency (RF) IVUS images.      Achievement: We developed an original method (patent pending) for segmenting the lumen, media and external boundaries of arteries from IVUS B-mode images. The development of this method will be pursued during the course of this grant.      Research plan: The IVUS B-mode image segmentation method will be improved to eliminate the manual initialization, radio-frequency data will be processed, and validation will be performed by using clinical data bases from patients that were recruited for prospective double-blinded clinical trials. The computation time will be improved by using a multi-resolution optimization method and the iterative conditional estimation algorithm. A template of the arterial media will be used to achieve automatic vessel wall detection of the different vessel layers. The segmentation algorithm will be adapted to RF data by exploiting the flexibility of the iterative conditional estimation of the probability density distribution of the image pixel intensity values.
Program
Discovery Grants Program - Individual
Location
Quebec, Canada
Recipient Type
Academia
Type
Grant
Source
NSERC's Awards Data

As published

Application id
138570-2006
Name nom
Cloutier, Guy
Department département
Radiologie, radio-oncologie et médecine nucléaire
Organization id
63
Institution établissement
Université de Montréal
Province en
Québec
Province fr
Québec
Country en
CANADA
Country fr
CANADA
Fiscal year exercice financier
2007
Competition year année de concours
2006
Award amount
47000
Program id
RGPIN
Program name en
Discovery Grants Program - Individual
Program name fr
Programme de subventions à la découverte - individuelles
Group en
Discovery grants programs
Group fr
Programmes de subventions à la découverte
Committee code
335
Committee name en
Electromag. & Electr. Systems (H)
Committee name fr
Électromagn. et syst. électr. (H)
Area of application code
1102
Area of application group en
Health, education and social services
Area of application group fr
Santé publique, éducation et services sociaux
Area of application en
Biomedical engineering
Area of application fr
Génie biomédical
Research subject code
1900
Research subject group en
Biomedical engineering
Research subject group fr
Génie biomédical
Research subject en
Biomedical engineering
Research subject fr
Génie biomédical
Partie
2
Nb partie
5
Application title
Image processing of medical ultrasound data
Keyword
NA
Application summary
The goal of this research program is the development and evaluation of the 3D intravascular ultrasound (IVUS) technology to improve the diagnosis and follow-up of patients with peripheral arterial and coronary artery diseases. Because of its good accuracy and possibility of measuring the atherosclerotic plaque volume, this research should impact the clinical community by providing a robust imaging method for atherosclerotic progression/regression clinical trials based on measurements of plaque volume.      Our specific objectives for the upcoming 5 years are: 1) to develop a fast 3D imaging algorithm for segmenting the plaque volume from IVUS images, 2) to develop a fully automatic method requiring no manual initialization, 3) to validate the accuracy and reproducibility of the image processing algorithm on large clinical data bases acquired from patients with femoropopliteal and coronary artery diseases, and 4) to adapt the 3D segmentation method to process the higher-resolution radio-frequency (RF) IVUS images.      Achievement: We developed an original method (patent pending) for segmenting the lumen, media and external boundaries of arteries from IVUS B-mode images. The development of this method will be pursued during the course of this grant.      Research plan: The IVUS B-mode image segmentation method will be improved to eliminate the manual initialization, radio-frequency data will be processed, and validation will be performed by using clinical data bases from patients that were recruited for prospective double-blinded clinical trials. The computation time will be improved by using a multi-resolution optimization method and the iterative conditional estimation algorithm. A template of the arterial media will be used to achieve automatic vessel wall detection of the different vessel layers. The segmentation algorithm will be adapted to RF data by exploiting the flexibility of the iterative conditional estimation of the probability density distribution of the image pixel intensity values.