Grant: Research Tools and Instruments - Category 1 (<$150,000)
McMaster University
$10,513.00
Upgrade for scanning ion-selective electrodes
FY 2007-08
Summary
Ion-selective electrodes can be used to measure the concentrations of physiological ions such as as sodium, potassium, calcium, chloride, and hydrogen, and toxins such as the heavy metal cadmium, the nitrogenous waste ammonium and the organic cation tetraethylammonium. The electrode voltage is proportional to the ion concentration. Biological transport of ions into or out of cells produces small changes in the concentrations of these ions near the surface of the cells. The scanning ion-selective electrode technique (SIET) measures the changes in the concentrations of ions at two points near the surface of the cells and permits calculation of the corresponding difference in concentration. In turn, this difference can be used to calculate the flux of the ion into or out of the cells. The technique is non-invasive, in that the cells are not touched by the microelectrode, and it permits measurements of ion fluxes in near real time. These measurements allow us to characterize the transport of ions by tissues such as the intestinal tract and the functional kidneys of insects. We are thus able to characterize the mechanisms of ion homeostasis in insects, and the control of homeostasis by hormones. Such knowledge is the foundation for development of compounds such as hormone analogues which perturb homeostasis and can thus act as novel and environmentally benign insecticides. In addition, measurements of the concentrations of certain organic ions can be used to assess how insects excrete toxins, including insecticides and their breakdown products. In this case as well, such knowledge can be used to design novel control strategies for pest species. For example, such measurements permit identification of compounds which are themselves non-toxic but interfere with insecticide excretion. Application of these compounds may thus allow lower doses of insecticides to be applied.
Program
Research Tools and Instruments - Category 1 (<$150,000)
Recipient
Location
Ontario, Canada
Recipient Type
Academia
Type
Grant
Source
NSERC's Awards Data
As published
Application id
359459-2008
Name nom
ODonnell, Michael
Department département
Biology
Organization id
27
Institution établissement
McMaster University
Province en
Ontario
Province fr
Ontario
Country en
CANADA
Country fr
CANADA
Fiscal year exercice financier
2007
Competition year année de concours
2008
Award amount
10513
Program id
EQPEQ
Program name en
Research Tools and Instruments - Category 1 (<$150,000)
Program name fr
Outils et instruments de recherche - catégorie 1 (<150 000$)
Group en
Discovery grants programs
Group fr
Programmes de subventions à la découverte
Committee code
1011
Committee name en
Integrative Animal Biology
Committee name fr
Biologie Animale Intégrative
Area of application code
1200
Area of application group en
Advancement of knowledge
Area of application group fr
Avancement des connaissances
Area of application en
Advancement of knowledge
Area of application fr
Avancement des connaissances
Research subject code
5504
Research subject group en
Animal biology
Research subject group fr
Biologie animale
Research subject en
Animal physiology and metabolism
Research subject fr
Physiologie et métabolisme des animaux
Partie
1
Nb partie
1
Application title
Upgrade for scanning ion-selective electrodes
Keyword
NA
Application summary
Ion-selective electrodes can be used to measure the concentrations of physiological ions such as as sodium, potassium, calcium, chloride, and hydrogen, and toxins such as the heavy metal cadmium, the nitrogenous waste ammonium and the organic cation tetraethylammonium. The electrode voltage is proportional to the ion concentration. Biological transport of ions into or out of cells produces small changes in the concentrations of these ions near the surface of the cells. The scanning ion-selective electrode technique (SIET) measures the changes in the concentrations of ions at two points near the surface of the cells and permits calculation of the corresponding difference in concentration. In turn, this difference can be used to calculate the flux of the ion into or out of the cells. The technique is non-invasive, in that the cells are not touched by the microelectrode, and it permits measurements of ion fluxes in near real time. These measurements allow us to characterize the transport of ions by tissues such as the intestinal tract and the functional kidneys of insects. We are thus able to characterize the mechanisms of ion homeostasis in insects, and the control of homeostasis by hormones. Such knowledge is the foundation for development of compounds such as hormone analogues which perturb homeostasis and can thus act as novel and environmentally benign insecticides. In addition, measurements of the concentrations of certain organic ions can be used to assess how insects excrete toxins, including insecticides and their breakdown products. In this case as well, such knowledge can be used to design novel control strategies for pest species. For example, such measurements permit identification of compounds which are themselves non-toxic but interfere with insecticide excretion. Application of these compounds may thus allow lower doses of insecticides to be applied.