Canada Spends Logo

Explore our Budget 2026 analysis

Grant: Engage Grants Program

University of Alberta

$25,000.00

Estimate Trajectory of the Ultrasound Scan using Inertia Sensor

FY 2017-18

Summary
The objectives of this project are to develop and validate tools to use ultrasound for medical imaging by a)developing an algorithm based on an inertia sensor, consisting of a 3 axis-accelerometer, a 3-axis gyroscopeand a 3-axis magnetometer, which is embedded inside the ultrasound probe to estimate the trajectory ofultrasound scan, b) integrating the trajectory information with 2D ultrasound scanned images to reconstruct 3Dimages and c) establishing the accuracy of the 3D reconstructed images. The developed algorithm will providescientific underpinning for Clarius' promotion of their ultrasound system for 3D images reconstruction. Thecurrent ultrasound system from Clarius is a handheld device which uses Wi-Fi Direct and Bluetooth to connectto an iOS or Android smart device to display 2D images. The data from the accelerometer, gyroscope andmagnetometer are sent to the smart device at 60 Hz with 14-bit resolution. Clarius has not yet implemented theinertia sensor data to provide position and orientation information. Integration of the gyroscope measurementsplus the magnetometer data should accurately estimate the orientation. The calculated orientation will becombined with the accelerometer data which subtracts the earth's gravity information and perform a doubleintegration to estimate the position. However, since the inertial measurements are usually noisy and biased, theintegration steps from angular velocity to rotation and from acceleration to position will introduce integrationdrift. To minimize the integration drift, a periodic reset or capturing data in a short period of time may resolvethe drifting problem.
Program
Engage Grants Program
Location
Alberta, Canada
Recipient Type
Academia
Type
Grant
Source
NSERC's Awards Data

As published

Application id
522817-2017
Name nom
Lou, Edmond
Department département
Electrical and Computer Engineering
Organization id
9
Institution établissement
University of Alberta
Province en
Alberta
Province fr
Alberta
Country en
CANADA
Country fr
CANADA
Fiscal year exercice financier
2017
Competition year année de concours
2017
Award amount
25000
Program id
EGP
Program name en
Engage Grants Program
Program name fr
Programme de subventions d'engagement partenariat
Group en
Research partnerships programs
Group fr
Programmes de partenariat
Committee code
1555
Committee name en
Prairie Internal Decision Committee
Committee name fr
Comité de décision interne pour les Prairies
Area of application code
515
Area of application group en
Manufacturing processes and products
Area of application group fr
Procédés et produits industriels
Area of application en
Instrumentation technology
Area of application fr
Technologie de l'instrumentation
Research subject code
2518
Research subject group en
Electrical and electronic engineering
Research subject group fr
Génie électrique et électronique
Research subject en
Instrumentation and measurements
Research subject fr
Instrumentation et mesures
Partie
1
Nb partie
1
Application title
Estimate Trajectory of the Ultrasound Scan using Inertia Sensor
Keyword
NSERC
Application summary
The objectives of this project are to develop and validate tools to use ultrasound for medical imaging by a)developing an algorithm based on an inertia sensor, consisting of a 3 axis-accelerometer, a 3-axis gyroscopeand a 3-axis magnetometer, which is embedded inside the ultrasound probe to estimate the trajectory ofultrasound scan, b) integrating the trajectory information with 2D ultrasound scanned images to reconstruct 3Dimages and c) establishing the accuracy of the 3D reconstructed images. The developed algorithm will providescientific underpinning for Clarius' promotion of their ultrasound system for 3D images reconstruction. Thecurrent ultrasound system from Clarius is a handheld device which uses Wi-Fi Direct and Bluetooth to connectto an iOS or Android smart device to display 2D images. The data from the accelerometer, gyroscope andmagnetometer are sent to the smart device at 60 Hz with 14-bit resolution. Clarius has not yet implemented theinertia sensor data to provide position and orientation information. Integration of the gyroscope measurementsplus the magnetometer data should accurately estimate the orientation. The calculated orientation will becombined with the accelerometer data which subtracts the earth's gravity information and perform a doubleintegration to estimate the position. However, since the inertial measurements are usually noisy and biased, theintegration steps from angular velocity to rotation and from acceleration to position will introduce integrationdrift. To minimize the integration drift, a periodic reset or capturing data in a short period of time may resolvethe drifting problem.