Summary
Precast concrete construction is a well established construction method that provides high-performance and long-lasting structures. A rating system for construction was developed in the USA called Leadership in Energy and Environmental Design (LEED) that promotes sustainable construction. One of the credits under the 70 point Canadian LEED program is given for durable building envelopes. Precast construction usually rates well within the LEED system, however to improve it even further, durable reinforcing materials should be used.
Fibre-reinforced polymer (FRP) bars are non-corrosive and non-magnetic. This proposal will elaborate on the challenges and advantages of using FRP in precast concrete construction. The use of fibre-reinforced polymer (FRP) reinforcement in precast construction will also contribute to producing durable and hence sustainable structures.
Before the long-term objective can be achieved, research is needed in several areas, design codes being the most important. Even though current FRP design codes have been in use for nearly a decade, some areas of design still require further research attention. One of these areas is shear design. Especially shear design of FRP prestressed girders have not been thoroughly investigated. The provisions of CSA S6-06, CSA S806-02 and ACI 440.4R-04 will be examined and their applicability to FRP prestressed I-girders will be validated. According to literature, FRP prestressed sections may fail in shear cracking plane due to tendon rupture by dowel action. As shear failures are very brittle, this needs to be avoided, for example by providing minimum stirrup spacing. None of the above mentioned codes provide stirrup spacing for FRP prestressed/reinforced members. It is essential that safe stirrup spacing requirements are developed for FRP reinforced/prestressed concrete beams.
Program
Discovery Grants Program - Individual
Recipient
Location
Manitoba, Canada
Recipient Type
Academia
Type
Grant
Source
NSERC's Awards Data
As published
Application id
227589-2009
Name nom
Svecova, Dagmar
Department département
Civil Engineering
Organization id
19
Institution établissement
University of Manitoba
Province en
Manitoba
Province fr
Manitoba
Country en
CANADA
Country fr
CANADA
Fiscal year exercice financier
2010
Competition year année de concours
2009
Award amount
22000
Program id
RGPIN
Program name en
Discovery Grants Program - Individual
Program name fr
Programme de subventions à la découverte - individuelles
Group en
Discovery grants programs
Group fr
Programmes de subventions à la découverte
Committee code
1061
Committee name en
Civil Engineering - A
Committee name fr
Génie civil - A
Area of application code
601
Area of application group en
Construction, urban and rural planning
Area of application group fr
Construction, urbanisme et aménagement rural
Area of application en
Structural engineering
Area of application fr
Génie des charpentes
Research subject code
1000
Research subject group en
Civil engineering
Research subject group fr
Génie civil
Research subject en
Civil engineering
Research subject fr
Génie civil
Partie
2
Nb partie
5
Application title
Use of FRP in precast members
Keyword
NSERC
Application summary
Precast concrete construction is a well established construction method that provides high-performance and long-lasting structures. A rating system for construction was developed in the USA called Leadership in Energy and Environmental Design (LEED) that promotes sustainable construction. One of the credits under the 70 point Canadian LEED program is given for durable building envelopes. Precast construction usually rates well within the LEED system, however to improve it even further, durable reinforcing materials should be used.
Fibre-reinforced polymer (FRP) bars are non-corrosive and non-magnetic. This proposal will elaborate on the challenges and advantages of using FRP in precast concrete construction. The use of fibre-reinforced polymer (FRP) reinforcement in precast construction will also contribute to producing durable and hence sustainable structures.
Before the long-term objective can be achieved, research is needed in several areas, design codes being the most important. Even though current FRP design codes have been in use for nearly a decade, some areas of design still require further research attention. One of these areas is shear design. Especially shear design of FRP prestressed girders have not been thoroughly investigated. The provisions of CSA S6-06, CSA S806-02 and ACI 440.4R-04 will be examined and their applicability to FRP prestressed I-girders will be validated. According to literature, FRP prestressed sections may fail in shear cracking plane due to tendon rupture by dowel action. As shear failures are very brittle, this needs to be avoided, for example by providing minimum stirrup spacing. None of the above mentioned codes provide stirrup spacing for FRP prestressed/reinforced members. It is essential that safe stirrup spacing requirements are developed for FRP reinforced/prestressed concrete beams.