Canada Spends Logo

Explore our Budget 2026 analysis

Grant: Discovery Grants Program - Individual

Carleton University

$37,000.00

Computational tools and algorithms for impedance imaging

FY 2019-20

Summary
Electrical impedance tomography (EIT) uses measurements at body surface electrodes to calculate an image of the internal electrical properties. Such images provide useful information in medicine (i.e. blood and air flow), geophysics (i.e. ground water and mineral localization), and industrial process monitoring. The applicant is an internationally recognized expert in algorithms for EIT imaging and functional image analysis. In the past grant period, contributions have been disseminated by a) leading of consensus projects on algorithms and data analysis, b) an open-source software tool which has become the most widely used in the field, c) in the scientific literature (53 journal papers), and d) supervising 21 graduate students, 4 PDFs and 60 undergraduate students. Software developed by the research team is a core component of three companies' products.******Overall, research will focus on two streams: first, a Robust Algorithms and Validation theme (funded by this grant), which will develop an image evaluation and “debugging” framework, and, using the core technology developed, an Applications theme (funded by collaborators and industrial partners).******Despite its successes, EIT has been criticized for a lack of robustness, as the inverse problem inherent to image reconstruction is ill-conditioned, so that small data or model inaccuracies can result in large image artefacts. This research program will address this issue by developing a set of tools to analyse and correct inverse problem solutions. While several individual tools have been developed (by the applicant and others), the core innovation of this project is an integrated evaluation/debugging software framework. Three new components will be developed: a model and data validation tool, models of non-ideal characteristics of electronics hardware and electrodes (such as amplifier input impedance and crosstalk), and an image inspection tool to query the data contributing to suspected artefacts.******At the same time, work will be pursued on applications of EIT technology for medical and geophysical applications. Medical applications will focus on dynamic lung imaging (for use with neonatal, intensive care, and obstructive lung disease patients) and hemodynamic monitoring (non-invasive blood pressure and cardiac output measures). Geophysical applications will focus on monitoring of groundwater and surface movement in unstable (landslide-prone) soils and permafrost regions.
Program
Discovery Grants Program - Individual
Location
Ontario, Canada
Recipient Type
Academia
Type
Grant
Source
NSERC's Awards Data

As published

Application id
RGPIN-2017-06249
Name nom
Adler, Andy
Department département
Systems and Computer Engineering
Organization id
23
Institution établissement
Carleton University
Province en
Ontario
Province fr
Ontario
Country en
CANADA
Country fr
CANADA
Fiscal year exercice financier
2019
Competition year année de concours
2017
Award amount
37000
Program id
RGPIN
Program name en
Discovery Grants Program - Individual
Program name fr
Programme de subventions à la découverte - individuelles
Group en
DISCOVERY RESEARCH
Group fr
RECHERCHE AXÉE SUR LA DÉCOUVERTE
Committee code
1510
Committee name en
Electrical and Computer Engineering
Committee name fr
Génie électrique et informatique
Area of application code
1102
Area of application group en
Health, education and social services
Area of application group fr
Santé publique, éducation et services sociaux
Area of application en
Biomedical engineering
Area of application fr
Génie biomédical
Research subject code
1900
Research subject group en
Biomedical engineering
Research subject group fr
Génie biomédical
Research subject en
Biomedical engineering
Research subject fr
Génie biomédical
Installment
inst:3 - 5
Partie
3
Nb partie
5
Application title
Computational tools and algorithms for impedance imaging
Keyword
NSERC
Application summary
Electrical impedance tomography (EIT) uses measurements at body surface electrodes to calculate an image of the internal electrical properties. Such images provide useful information in medicine (i.e. blood and air flow), geophysics (i.e. ground water and mineral localization), and industrial process monitoring. The applicant is an internationally recognized expert in algorithms for EIT imaging and functional image analysis. In the past grant period, contributions have been disseminated by a) leading of consensus projects on algorithms and data analysis, b) an open-source software tool which has become the most widely used in the field, c) in the scientific literature (53 journal papers), and d) supervising 21 graduate students, 4 PDFs and 60 undergraduate students. Software developed by the research team is a core component of three companies' products.******Overall, research will focus on two streams: first, a Robust Algorithms and Validation theme (funded by this grant), which will develop an image evaluation and “debugging” framework, and, using the core technology developed, an Applications theme (funded by collaborators and industrial partners).******Despite its successes, EIT has been criticized for a lack of robustness, as the inverse problem inherent to image reconstruction is ill-conditioned, so that small data or model inaccuracies can result in large image artefacts. This research program will address this issue by developing a set of tools to analyse and correct inverse problem solutions. While several individual tools have been developed (by the applicant and others), the core innovation of this project is an integrated evaluation/debugging software framework. Three new components will be developed: a model and data validation tool, models of non-ideal characteristics of electronics hardware and electrodes (such as amplifier input impedance and crosstalk), and an image inspection tool to query the data contributing to suspected artefacts.******At the same time, work will be pursued on applications of EIT technology for medical and geophysical applications. Medical applications will focus on dynamic lung imaging (for use with neonatal, intensive care, and obstructive lung disease patients) and hemodynamic monitoring (non-invasive blood pressure and cardiac output measures). Geophysical applications will focus on monitoring of groundwater and surface movement in unstable (landslide-prone) soils and permafrost regions.
Carleton University - $37,000 Grant (2019-20) | Canada Spends