Grant: Discovery Grants Program - Individual
University of Alberta
$23,000.00
Evaluation of the Mechanical Properties of the Bone-Implant Interface
FY 2024-25
Summary
Skin-penetrating bone-anchored implants are used in a variety of applications to provide tremendous functional benefits to patients. Globally, the dental implant industry has been valued at 5.08 billion USD where implants are used for replacing single teeth, for larger prostheses, and for full dental arches. Bone-anchored-hearing-aids have been available since the 1970s with more than 150,000 global users. Further, bone-anchored implants are used to reconstruct facial features in the orbital, nasal, and auricular regions and in jaw reconstruction using fibular grafts. These implants rely on the structural integrity of the bone-implant interface through a process called osseointegration.
Similar concepts of interface integrity can be applied to natural interfaces, such as the bone-ligament-tooth complex of a natural tooth. In this case, the interface is the periodontal ligament (PDL) which connects the tooth root to the surrounding bone. It is estimated that Canadian expenditures on dental services in 2015 reached $13.6 billion. The PDL is a vital structure in dental health with critical functions in tooth stability and orthodontic movement.
Noninvasively evaluating the interface integrity in both bone-anchored implants and natural teeth is critically important to understanding the behaviour of these structures in a clinical setting. For the bone-implant interface, this is important to prescribe loading, identify the risk of failure, and monitor the long-term implant health. Similarly, evaluating the complex tooth-ligament-bone structure is important in diagnosing periodontal disease, assessing the PDL after trauma, and understanding the changes associated with orthodontic treatment.
The long-term goal of this program is to advance the understanding of the mechanical and biological behaviour of interface tissues in bone-anchored implants and natural teeth. The short-term objectives will focus on:
O1: Evaluating osseointegration at the bone implant interface in implants used for craniofacial reconstruction and dental implants
O2: Evaluating the integrity of the PDL in natural teeth
O3: Validation of the analytical modeling approach
The proposed approach uses an acceleration measurement during an impact with the mechanical biological system combined with an analytical model. Numerical analysis is used to couple the experimental measurement with the model to estimate the interface properties. The analytical models are developed through laboratory testing and further evaluated with real patient data. The models will be validated through detailed finite element models and destructive mechanical testing.
This research program will provide valuable insight into relevant questions such as appropriate timelines for implant loading, detection of implant failure, and assessment of various stages of tooth stability. The validation of the approach will strengthen the utility of the technique while providing a strong foundation for further research.
Program
Discovery Grants Program - Individual
Recipient
Location
Alberta, Canada
Recipient Type
Academia
Type
Grant
Source
NSERC's Awards Data
As published
Application id
RGPIN-2020-04621
Name nom
Westover, Lindsey
Department département
Mechanical Engineering
Organization id
9
Institution établissement
University of Alberta
Province en
Alberta
Province fr
Alberta
Country en
CANADA
Country fr
CANADA
Fiscal year exercice financier
2024
Competition year année de concours
2020
Award amount
23000
Program id
RGPIN
Program name en
Discovery Grants Program - Individual
Program name fr
Programme de subventions à la découverte - individuelles
Group en
DISCOVERY RESEARCH
Group fr
RECHERCHE AXÉE SUR LA DÉCOUVERTE
Committee code
1512
Committee name en
Mechanical Engineering
Committee name fr
Génie mécanique
Area of application code
405
Area of application group en
Environment
Area of application group fr
Environnement
Area of application en
Modelling and mathematical simulation of natural processes
Area of application fr
Modélisation et simulation mathématique des processus naturels
Research subject code
2104
Research subject group en
Mechanical engineering
Research subject group fr
Génie mécanique
Research subject en
Vibrations
Research subject fr
Vibrations
Field of research list names en
Not available
Field of research list names fr
Non disponible
Socioeconomic objective list names en
Not available
Socioeconomic objective list names fr
Non disponible
Application title
Evaluation of the Mechanical Properties of the Bone-Implant Interface
Keywords
mechanical evaluation; vibration analysis; nondestructive testing; numerical analysis; osseointegration; tissue mechanics; interface integrity; dental biomechanics
Application summary
Skin-penetrating bone-anchored implants are used in a variety of applications to provide tremendous functional benefits to patients. Globally, the dental implant industry has been valued at 5.08 billion USD where implants are used for replacing single teeth, for larger prostheses, and for full dental arches. Bone-anchored-hearing-aids have been available since the 1970s with more than 150,000 global users. Further, bone-anchored implants are used to reconstruct facial features in the orbital, nasal, and auricular regions and in jaw reconstruction using fibular grafts. These implants rely on the structural integrity of the bone-implant interface through a process called osseointegration.
Similar concepts of interface integrity can be applied to natural interfaces, such as the bone-ligament-tooth complex of a natural tooth. In this case, the interface is the periodontal ligament (PDL) which connects the tooth root to the surrounding bone. It is estimated that Canadian expenditures on dental services in 2015 reached $13.6 billion. The PDL is a vital structure in dental health with critical functions in tooth stability and orthodontic movement.
Noninvasively evaluating the interface integrity in both bone-anchored implants and natural teeth is critically important to understanding the behaviour of these structures in a clinical setting. For the bone-implant interface, this is important to prescribe loading, identify the risk of failure, and monitor the long-term implant health. Similarly, evaluating the complex tooth-ligament-bone structure is important in diagnosing periodontal disease, assessing the PDL after trauma, and understanding the changes associated with orthodontic treatment.
The long-term goal of this program is to advance the understanding of the mechanical and biological behaviour of interface tissues in bone-anchored implants and natural teeth. The short-term objectives will focus on:
O1: Evaluating osseointegration at the bone implant interface in implants used for craniofacial reconstruction and dental implants
O2: Evaluating the integrity of the PDL in natural teeth
O3: Validation of the analytical modeling approach
The proposed approach uses an acceleration measurement during an impact with the mechanical biological system combined with an analytical model. Numerical analysis is used to couple the experimental measurement with the model to estimate the interface properties. The analytical models are developed through laboratory testing and further evaluated with real patient data. The models will be validated through detailed finite element models and destructive mechanical testing.
This research program will provide valuable insight into relevant questions such as appropriate timelines for implant loading, detection of implant failure, and assessment of various stages of tooth stability. The validation of the approach will strengthen the utility of the technique while providing a strong foundation for further research.