Grant: Discovery Grants Program - Individual
University of Alberta
$41,000.00
Development of Multiparametric MRI of Mixed Water and Fat Tissues
FY 2024-25
Summary
Several organ systems (e.g. skeletal muscle, liver, .) are composed of a mixture of water and fat, particularly in the setting of obesity, which is now the most common healthy condition worldwide (>27% of Canadians are obese). The quantification of fat content within these organs is a primary target for health research and clinical assessment (MRI is the gold standard test), and it is increasingly recognized that the fat itself is a confounder of water-based imaging tests, in particular, for quantitative MRI. Quantitative imaging of parameters such as tissue T1 (longitudinal relaxation time) are now commonly used; for example, liver T1 mapping is used to detect fibrosis. My group has shown that the most commonly used T1 mapping methods have large and complex T1 errors when fat is present. Quantitative susceptibility (X) mapping (QSM), which is complimentary to T1, has been proposed evaluate liver iron content and fibrosis. Several factors will affect magnetic susceptibility in the liver including iron concentration, fat concentration and fibrosis (all targeted pathological features) and thus interpretation of X requires the measurement of additional imaging parameters (critically, fat content). Imaging of multiple parameters is also required for accurate quantification of fat content itself (termed proton density fat fraction, PDFF) including T2* and a magnetic field map. Ideally, quantitative MRI in these fat-bearing organs would include fat and water separation with simultaneous imaging of PDFF, T1Water and T2*Water (without fat-mediated errors) and X. Joint acquisition and post-processing together offers improved efficiency (one-stop-shop pulse sequence with all different parameters intrinsically spatially registered), increased accuracy (correct values) and increased precision (less noise related variability). Our program goals are to develop new MRI methods for the simultaneous acquisition of several key parameters including fat content (PDFF), water-specific T1 and T2* and magnetic susceptibility and field maps with the aim of increasing accuracy, precession and reproducibility with targeted application in the liver and skeletal muscle.
Summary
MRI is the gold standard test for the quantification of pathologic fat pools, both bulk fat (e.g. visceral fat between organs) and intra-organ fat (hepatic fat (liver), intermuscular fat) and separately, key tissue properties such as fibrosis. However, current methods have critical systematic errors in mixed water and fat tissues, and the requirement for multiple complimentary parameters necessitates efficient multiparametric approaches that are also accurate and have no fat-related bias. We will build on our expertise in quantitative multiparametric MRI to design, validate and implement new MRI pulse sequences that meet these requirements (T1Water, T2*Water, X, field maps and PDFF) for application in the liver and skeletal muscle.
Program
Discovery Grants Program - Individual
Recipient
Location
Alberta, Canada
Recipient Type
Academia
Type
Grant
Source
NSERC's Awards Data
As published
Application id
RGPIN-2024-05069
Name nom
Thompson, Richard
Department département
Biomedical Engineering
Organization id
9
Institution établissement
University of Alberta
Province en
Alberta
Province fr
Alberta
Country en
CANADA
Country fr
CANADA
Fiscal year exercice financier
2024
Competition year année de concours
2024
Award amount
41000
Program id
RGPIN
Program name en
Discovery Grants Program - Individual
Program name fr
Programme de subventions à la découverte - individuelles
Group en
DISCOVERY RESEARCH
Group fr
RECHERCHE AXÉE SUR LA DÉCOUVERTE
Committee code
1505
Committee name en
Physics
Committee name fr
Physique
Area of application code
1102
Area of application group en
Health, education and social services
Area of application group fr
Santé publique, éducation et services sociaux
Area of application en
Biomedical engineering
Area of application fr
Génie biomédical
Research subject code
1900
Research subject group en
Biomedical engineering
Research subject group fr
Génie biomédical
Research subject en
Biomedical engineering
Research subject fr
Génie biomédical
Field of research list names en
Not available
Field of research list names fr
Non disponible
Socioeconomic objective list names en
Not available
Socioeconomic objective list names fr
Non disponible
Application title
Development of Multiparametric MRI of Mixed Water and Fat Tissues
Keywords
nuclear magnetic resonance; magnetic resonance imaging; fat; magnetic susceptibility; adipose tissue; spectroscopic imaging; relaxation
Application summary
Several organ systems (e.g. skeletal muscle, liver, .) are composed of a mixture of water and fat, particularly in the setting of obesity, which is now the most common healthy condition worldwide (>27% of Canadians are obese). The quantification of fat content within these organs is a primary target for health research and clinical assessment (MRI is the gold standard test), and it is increasingly recognized that the fat itself is a confounder of water-based imaging tests, in particular, for quantitative MRI. Quantitative imaging of parameters such as tissue T1 (longitudinal relaxation time) are now commonly used; for example, liver T1 mapping is used to detect fibrosis. My group has shown that the most commonly used T1 mapping methods have large and complex T1 errors when fat is present. Quantitative susceptibility (X) mapping (QSM), which is complimentary to T1, has been proposed evaluate liver iron content and fibrosis. Several factors will affect magnetic susceptibility in the liver including iron concentration, fat concentration and fibrosis (all targeted pathological features) and thus interpretation of X requires the measurement of additional imaging parameters (critically, fat content). Imaging of multiple parameters is also required for accurate quantification of fat content itself (termed proton density fat fraction, PDFF) including T2* and a magnetic field map. Ideally, quantitative MRI in these fat-bearing organs would include fat and water separation with simultaneous imaging of PDFF, T1Water and T2*Water (without fat-mediated errors) and X. Joint acquisition and post-processing together offers improved efficiency (one-stop-shop pulse sequence with all different parameters intrinsically spatially registered), increased accuracy (correct values) and increased precision (less noise related variability). Our program goals are to develop new MRI methods for the simultaneous acquisition of several key parameters including fat content (PDFF), water-specific T1 and T2* and magnetic susceptibility and field maps with the aim of increasing accuracy, precession and reproducibility with targeted application in the liver and skeletal muscle.
Summary
MRI is the gold standard test for the quantification of pathologic fat pools, both bulk fat (e.g. visceral fat between organs) and intra-organ fat (hepatic fat (liver), intermuscular fat) and separately, key tissue properties such as fibrosis. However, current methods have critical systematic errors in mixed water and fat tissues, and the requirement for multiple complimentary parameters necessitates efficient multiparametric approaches that are also accurate and have no fat-related bias. We will build on our expertise in quantitative multiparametric MRI to design, validate and implement new MRI pulse sequences that meet these requirements (T1Water, T2*Water, X, field maps and PDFF) for application in the liver and skeletal muscle.