Canada Spends Logo

Explore our Budget 2026 analysis

Grant: Discovery Grants Program - Individual

University of Manitoba

$20,000.00

Improving the long-term performance of modular connections in artificial joints

FY 2012-13

Summary
Artificial joints have been used in increasing numbers since the middle of the last century to treat patients with diseased joints. Early on, mainly hip and knee joints were treated, and the devices were rarely implanted in persons younger than 60 years, as the implant survival rate was typically less than 15 years. Artificial joints have improved much in the last 50 years, and an implant survival rate of 90% or more can be expected after 15 years, in spite of the fact that they are increasingly being implanted in younger and more active patients. Improvements that were introduced in the last few years included manufacturing of artificial joints in separate pieces, such as the head, neck and stem in hip joints, and assembling them during surgery for both, primary and revision surgery. These so-called modular designs allow surgeons intra-operatively to optimally adjust the size, alignment, type of the articulation and fixation to an individual patient. Despite enormous efforts using computer modeling and elaborate near physiological testing, it appears that some of these newer primary and revision designs develop problems at their modular connections. More frequently, there is an increase in corrosion at the modular head-neck interface of hip joints, especially in hips with larger heads that can lead to tissue reactions such as the formation of cysts, pseudotumors and muscle damage. The long term goal of this research is to improve the performance of modular connections in artificial joints to achieve a reduction of revisions due to fractures and corrosion. The first study the applicant and his students will look at is the corrosion and fretting damage at head-neck tapers. The novel tests will be validated by reproducing clinical ""damage"" observed in a sample of retrieved artificial joints. The expected reduction of revision surgeries will increase the successful long-term performance of artificial joints benefitting the patients, and reduce the costs to health care. Training of engineering HQP in this area of expertise at the University of Manitoba and the Concordia Hip and Knee Institute will support the growth of the medical device industry in Canada.
Program
Discovery Grants Program - Individual
Location
Manitoba, Canada
Recipient Type
Academia
Type
Grant
Source
NSERC's Awards Data

As published

Application id
6346-2012
Name nom
Wyss, Urs
Department département
Mechanical and Manufacturing Engineering
Organization id
19
Institution établissement
University of Manitoba
Province en
Manitoba
Province fr
Manitoba
Country en
CANADA
Country fr
CANADA
Fiscal year exercice financier
2012
Competition year année de concours
2012
Award amount
20000
Program id
RGPIN
Program name en
Discovery Grants Program - Individual
Program name fr
Programme de subventions à la découverte - individuelles
Group en
Discovery grants programs
Group fr
Programmes de subventions à la découverte
Committee code
1512
Committee name en
Mechanical Engineering
Committee name fr
Génie mécanique
Area of application code
1102
Area of application group en
Health, education and social services
Area of application group fr
Santé publique, éducation et services sociaux
Area of application en
Biomedical engineering
Area of application fr
Génie biomédical
Research subject code
2100
Research subject group en
Mechanical engineering
Research subject group fr
Génie mécanique
Research subject en
Mechanical engineering
Research subject fr
Génie mécanique
Partie
1
Nb partie
1
Application title
Improving the long-term performance of modular connections in artificial joints
Keyword
NSERC
Application summary
Artificial joints have been used in increasing numbers since the middle of the last century to treat patients with diseased joints. Early on, mainly hip and knee joints were treated, and the devices were rarely implanted in persons younger than 60 years, as the implant survival rate was typically less than 15 years. Artificial joints have improved much in the last 50 years, and an implant survival rate of 90% or more can be expected after 15 years, in spite of the fact that they are increasingly being implanted in younger and more active patients. Improvements that were introduced in the last few years included manufacturing of artificial joints in separate pieces, such as the head, neck and stem in hip joints, and assembling them during surgery for both, primary and revision surgery. These so-called modular designs allow surgeons intra-operatively to optimally adjust the size, alignment, type of the articulation and fixation to an individual patient. Despite enormous efforts using computer modeling and elaborate near physiological testing, it appears that some of these newer primary and revision designs develop problems at their modular connections. More frequently, there is an increase in corrosion at the modular head-neck interface of hip joints, especially in hips with larger heads that can lead to tissue reactions such as the formation of cysts, pseudotumors and muscle damage. The long term goal of this research is to improve the performance of modular connections in artificial joints to achieve a reduction of revisions due to fractures and corrosion. The first study the applicant and his students will look at is the corrosion and fretting damage at head-neck tapers. The novel tests will be validated by reproducing clinical ""damage"" observed in a sample of retrieved artificial joints. The expected reduction of revision surgeries will increase the successful long-term performance of artificial joints benefitting the patients, and reduce the costs to health care. Training of engineering HQP in this area of expertise at the University of Manitoba and the Concordia Hip and Knee Institute will support the growth of the medical device industry in Canada.