Grant: Discovery Grants Program - Individual
École Polytechnique de Montréal
$52,000.00
Improved design and operations of building water systems to reduce health risks caused by water & energy conservation and extended shutdowns
FY 2023-24
Summary
Stagnation of water in building water systems can cause elevated concentrations of toxic metals and pathogens such as Legionella pneumophila, Pseudomonas aeruginosa and Non Tuberculus Mycobacteria. Pathogens can be amplified within building water systems and cause outbreaks and community acquired disease. Legionella is now the most common cause of drinking water associated outbreaks and Legionnaire's disease rates are increasing rapidly. Maintaining water quality in buildings is a growing challenge because of the unintended consequences of water and energy conservations measures that have been shown to increase health risks. Such measures are highly justified but have unfortunately been implemented to legacy building systems without regard for water quality, often causing severe water quality losses. Recently, the SARS-CoV-2 global pandemic forced extended closures of a staggering number of buildings across Canada with extreme stagnation causing unsafe water. The research program aims to provide the evidence to base recommendations to improve the design and operations of building water systems and ensure the provision of safe water. The widespread implementation of low flow devices and thermostatic valves impacts water quality building in water systems. Energy conservation measures for hot water systems in large buildings such as heat exchangers, lowering of temperature set points have led to the proliferation of Legionella causing documented cases and fatalities in Canadian health care facilities. The consequences of these conservation measures is poorly documented and need to be quantified. The research program will address the key knowledge gaps through a combination of field investigations, pilot and bench scale assays, laboratory studies, risk analysis and regulatory impact investigations. Field studies will document the prevalence of pathogens, microbial diversity and the presence of toxic metals in building water systems across Canada using innovative sampling strategies. Intervention field studies will document the impacts of commissioning procedures and water conservation retrofits. Pilot studies will focus on the interplay between materials, water quality and water usage. Laboratory and bench-scale studies will quantify the production of aerosols and colonization potential of low flow faucets and showers to quantify the exposure pathways. Risk analysis (QMRA) models will be used to guide the selection of alert and action levels and define optimal regulatory frameworks. Research results will provide actionable evidence to reduce health risks to their occupants and will be conducted in close collaboration with utilities, regulators and associations with the clear intent of providing: a basis for streamlined and effective guidance and regulations, cost effective environmental monitoring programs, modifications of the building code, drinking water compatible material certification and reviewed building water system design approaches.
Program
Discovery Grants Program - Individual
Recipient
Location
Quebec, Canada
Recipient Type
Academia
Type
Grant
Source
NSERC's Awards Data
As published
Application id
RGPIN-2021-04341
Name nom
Prévost, Michèle
Department département
Génies civil, géologique et des mines
Organization id
64
Institution établissement
École Polytechnique de Montréal
Province en
Québec
Province fr
Québec
Country en
CANADA
Country fr
CANADA
Fiscal year exercice financier
2023
Competition year année de concours
2021
Award amount
52000
Program id
RGPIN
Program name en
Discovery Grants Program - Individual
Program name fr
Programme de subventions à la découverte - individuelles
Group en
DISCOVERY RESEARCH
Group fr
RECHERCHE AXÉE SUR LA DÉCOUVERTE
Committee code
1509
Committee name en
Civil, Industrial and Systems Engineering
Committee name fr
Génie civil, industriel et des systèmes
Area of application code
1206
Area of application group en
Advancement of knowledge
Area of application group fr
Avancement des connaissances
Area of application en
Engineering
Area of application fr
Génie
Research subject code
1501
Research subject group en
Environmental engineering
Research subject group fr
Water quality, pollution
Research subject en
Génie de l'environnement
Research subject fr
Qualité de l'eau, pollution
Application title
Improved design and operations of building water systems to reduce health risks caused by water & energy conservation and extended shutdowns
Keyword
building water quality; building water systems; commissioning; corrosion; hot water system; lead and copper; legionella; QMRA; stagnation; water and energy conservation
Application summary
Stagnation of water in building water systems can cause elevated concentrations of toxic metals and pathogens such as Legionella pneumophila, Pseudomonas aeruginosa and Non Tuberculus Mycobacteria. Pathogens can be amplified within building water systems and cause outbreaks and community acquired disease. Legionella is now the most common cause of drinking water associated outbreaks and Legionnaire's disease rates are increasing rapidly. Maintaining water quality in buildings is a growing challenge because of the unintended consequences of water and energy conservations measures that have been shown to increase health risks. Such measures are highly justified but have unfortunately been implemented to legacy building systems without regard for water quality, often causing severe water quality losses. Recently, the SARS-CoV-2 global pandemic forced extended closures of a staggering number of buildings across Canada with extreme stagnation causing unsafe water. The research program aims to provide the evidence to base recommendations to improve the design and operations of building water systems and ensure the provision of safe water. The widespread implementation of low flow devices and thermostatic valves impacts water quality building in water systems. Energy conservation measures for hot water systems in large buildings such as heat exchangers, lowering of temperature set points have led to the proliferation of Legionella causing documented cases and fatalities in Canadian health care facilities. The consequences of these conservation measures is poorly documented and need to be quantified. The research program will address the key knowledge gaps through a combination of field investigations, pilot and bench scale assays, laboratory studies, risk analysis and regulatory impact investigations. Field studies will document the prevalence of pathogens, microbial diversity and the presence of toxic metals in building water systems across Canada using innovative sampling strategies. Intervention field studies will document the impacts of commissioning procedures and water conservation retrofits. Pilot studies will focus on the interplay between materials, water quality and water usage. Laboratory and bench-scale studies will quantify the production of aerosols and colonization potential of low flow faucets and showers to quantify the exposure pathways. Risk analysis (QMRA) models will be used to guide the selection of alert and action levels and define optimal regulatory frameworks. Research results will provide actionable evidence to reduce health risks to their occupants and will be conducted in close collaboration with utilities, regulators and associations with the clear intent of providing: a basis for streamlined and effective guidance and regulations, cost effective environmental monitoring programs, modifications of the building code, drinking water compatible material certification and reviewed building water system design approaches.