Canada Spends Logo

Explore our Budget 2026 analysis

Grant: Engage Grants Program

Carleton University

$25,000.00

Multi-leaf collimator for cobalt radiation cancer therapy

FY 2010-11

Summary
Today people with cancer are living longer than in the past because of early detection and effective treatments. The most common and effective treatment plans often include radiation therapy, and historically this has meant Cobalt-60 External Beam Radiotherapy, or Co60 treatment for short. Co60 cancer treatments have been used since the middle of the last century with great success. The objective of this project is to enhance the effectiveness of these treatments by designing a new feature, a multi-leaf collimator (MLC), that will be added onto current Co60 irradiation devices. The proposed MLC would shape the radiation beam in two dimensions to match the two-dimensional shape of the tumor: the procedure is called conformal irradiation. The MLC would have many (55 to 120) pairs of leaves made of high density material to stop gamma radiation. During treatments, the leaves would move individually to define a predetermined two-dimensional shape that would vary as the irradiation source is rotated about the patient. Matching the shape of the beam to the shape of the tumor maximizes the radiation dose to the tumor while minimizing collateral damage to the surrounding healthy tissue. The MLC will be designed to fit into the ""Equinox"", which is the state-of-the-art instrument built and sold by the partner organization: Best Theratronics Limited in Ottawa. Cobalt-60 radiotherapy is a cost-effective and robust cancer treatment that has benefited millions. The MLC that will be developed following this work will enhance the efficacy of future treatments.
Program
Engage Grants Program
Location
Ontario, Canada
Recipient Type
Academia
Type
Grant
Source
NSERC's Awards Data

As published

Application id
404843-2010
Name nom
McRae, Glenn
Department département
Mechanical & Aerospace Engineering
Organization id
23
Institution établissement
Carleton University
Province en
Ontario
Province fr
Ontario
Country en
CANADA
Country fr
CANADA
Fiscal year exercice financier
2010
Competition year année de concours
2010
Award amount
25000
Program id
EGP
Program name en
Engage Grants Program
Program name fr
Programme de subventions d'engagement partenariat
Group en
Research partnerships programs
Group fr
Programmes de partenariat
Committee code
1553
Committee name en
Ontario Internal Decision Committee
Committee name fr
Comité de décision interne pour l'Ontario
Area of application code
1102
Area of application group en
Health, education and social services
Area of application group fr
Santé publique, éducation et services sociaux
Area of application en
Biomedical engineering
Area of application fr
Génie biomédical
Research subject code
1900
Research subject group en
Biomedical engineering
Research subject group fr
Génie biomédical
Research subject en
Biomedical engineering
Research subject fr
Génie biomédical
Partie
1
Nb partie
1
Application title
Multi-leaf collimator for cobalt radiation cancer therapy
Keyword
NSERC
Application summary
Today people with cancer are living longer than in the past because of early detection and effective treatments. The most common and effective treatment plans often include radiation therapy, and historically this has meant Cobalt-60 External Beam Radiotherapy, or Co60 treatment for short. Co60 cancer treatments have been used since the middle of the last century with great success. The objective of this project is to enhance the effectiveness of these treatments by designing a new feature, a multi-leaf collimator (MLC), that will be added onto current Co60 irradiation devices. The proposed MLC would shape the radiation beam in two dimensions to match the two-dimensional shape of the tumor: the procedure is called conformal irradiation. The MLC would have many (55 to 120) pairs of leaves made of high density material to stop gamma radiation. During treatments, the leaves would move individually to define a predetermined two-dimensional shape that would vary as the irradiation source is rotated about the patient. Matching the shape of the beam to the shape of the tumor maximizes the radiation dose to the tumor while minimizing collateral damage to the surrounding healthy tissue. The MLC will be designed to fit into the ""Equinox"", which is the state-of-the-art instrument built and sold by the partner organization: Best Theratronics Limited in Ottawa. Cobalt-60 radiotherapy is a cost-effective and robust cancer treatment that has benefited millions. The MLC that will be developed following this work will enhance the efficacy of future treatments.