Grant: Discovery Grants Program - Individual
Carleton University
$22,000.00
Comprehensive Experimental and CFD Investigations of Pharmaceutical Aerosol Devices
FY 2015-16
Summary
Pressurized metered-dose inhalers (pMDIs) or ""puffers"", dry powder inhalers (DPIs), and nebulizers are normally used in the treatment of lung diseases, such as asthma and bronchitis. Statistics from Lung Associations indicate that up to approximately 10% of the population may suffer from respiratory illnesses requiring treatment in part of their lives. Inhaler devices produce very complex turbulent flows and ideal medication delivery remains a challenging engineering problem. Considerable amounts of aerosol medication generated from the pMDIs are deposited and lost on the walls of the upper airways (mouth-throat-trachea) before reaching the target (or the lungs), resulting in considerable medication losses from a single dosage (Fink, 2000). Add-on spacers are devices that are attached to the pMDIs and will enhance the total amount of medication delivered to the lungs.
<span style=""line-height: 1.5em;"">Besides medication delivery to the lungs, nasal drug delivery using pharmaceutical aerosols is emerging as an important alternative for treating many conditions such as diabetes (insulin delivery), osteoporosis, and even migraine headaches. Due to complexity of the nasal cavity and differences in regional medication absorptiveness, which is also affected by the medication properties (formulation and aerosol characteristics, i.e., density, shape and size of individual particles) and fluid flow structures, the ideal nasal drug delivery remains a challenging problem. In collaboration with the Ottawa Civic Hospital, we have developed a novel and idealized nasal cavity geometry, which is a potential candidate to be used as a standard (for aerosol deposition measurements) in the pharmaceutical field.
<span style=""line-height: 1.5em;""><span style=""line-height: 1.5em;"">Despite the importance and growing interest in inhaled medications, research and development of pharmaceutical aerosol devices have focused more on therapeutical effectiveness. More efficient inhalation devices could improve the treatment of patients by reducing side effects and improving patient compliance. The present proposed research aims at the better understanding of the physics involved in aerosol drug delivery systems (both lung and nasal) and the improvement of the performance of inhalation devices in terms of maximizing medication delivery, through on-going comprehensive studies of aerosol generation, transport, and deposition inside devices themselves and mainly in extrathoracic airways (nose-mouth-throat), using experimental analysis (aerosol deposition and fluid flow measurements) and Computational Fluid Dynamics (CFD). The author also wishes to use similar approaches and expand the investigations towards the understanding (transport and extra-thoracic deposition mechanisms) and characterization of airborne allergic triggers with a focus on PM2.5 (particulate matter with diameter smaller than 2.5 microns), especially nanoparticles.
Program
Discovery Grants Program - Individual
Recipient
Location
Ontario, Canada
Recipient Type
Academia
Type
Grant
Source
NSERC's Awards Data
As published
Application id
RGPIN-2015-05624
Name nom
Matida, Edgar
Department département
Engineering and Design, Faculty of - Engineering and Design, Faculty of
Organization id
23
Institution établissement
Carleton University
Province en
Ontario
Province fr
Ontario
Country en
CANADA
Country fr
CANADA
Fiscal year exercice financier
2015
Competition year année de concours
2015
Award amount
22000
Program id
RGPIN
Program name en
Discovery Grants Program - Individual
Program name fr
Programme de subventions à la découverte - individuelles
Group en
Discovery grants programs
Group fr
Programmes de subventions à la découverte
Committee code
1512
Committee name en
Mechanical Engineering
Committee name fr
Génie mécanique
Area of application code
1102
Area of application group en
Health, education and social services
Area of application group fr
Santé publique, éducation et services sociaux
Area of application en
Biomedical engineering
Area of application fr
Génie biomédical
Research subject code
2100
Research subject group en
Mechanical engineering
Research subject group fr
Génie mécanique
Research subject en
Mechanical engineering
Research subject fr
Génie mécanique
Partie
1
Nb partie
1
Application title
Comprehensive Experimental and CFD Investigations of Pharmaceutical Aerosol Devices
Keyword
NSERC
Application summary
<p>Pressurized metered-dose inhalers (pMDIs) or ""puffers"", dry powder inhalers (DPIs), and nebulizers are normally used in the treatment of lung diseases, such as asthma and bronchitis. Statistics from Lung Associations indicate that up to approximately 10% of the population may suffer from respiratory illnesses requiring treatment in part of their lives. Inhaler devices produce very complex turbulent flows and ideal medication delivery remains a challenging engineering problem. Considerable amounts of aerosol medication generated from the pMDIs are deposited and lost on the walls of the upper airways (mouth-throat-trachea) before reaching the target (or the lungs), resulting in considerable medication losses from a single dosage (Fink, 2000). Add-on spacers are devices that are attached to the pMDIs and will enhance the total amount of medication delivered to the lungs. </p>
<p><span style=""line-height: 1.5em;"">Besides medication delivery to the lungs, nasal drug delivery using pharmaceutical aerosols is emerging as an important alternative for treating many conditions such as diabetes (insulin delivery), osteoporosis, and even migraine headaches. Due to complexity of the nasal cavity and differences in regional medication absorptiveness, which is also affected by the medication properties (formulation and aerosol characteristics, i.e., density, shape and size of individual particles) and fluid flow structures, the ideal nasal drug delivery remains a challenging problem. In collaboration with the Ottawa Civic Hospital, we have developed a novel and idealized nasal cavity geometry, which is a potential candidate to be used as a standard (for aerosol deposition measurements) in the pharmaceutical field. </span></p>
<p><span style=""line-height: 1.5em;""></span><span style=""line-height: 1.5em;"">Despite the importance and growing interest in inhaled medications, research and development of pharmaceutical aerosol devices have focused more on therapeutical effectiveness. More efficient inhalation devices could improve the treatment of patients by reducing side effects and improving patient compliance. The present proposed research aims at the better understanding of the physics involved in aerosol drug delivery systems (both lung and nasal) and the improvement of the performance of inhalation devices in terms of maximizing medication delivery, through on-going comprehensive studies of aerosol generation, transport, and deposition inside devices themselves and mainly in extrathoracic airways (nose-mouth-throat), using experimental analysis (aerosol deposition and fluid flow measurements) and Computational Fluid Dynamics (CFD). The author also wishes to use similar approaches and expand the investigations towards the understanding (transport and extra-thoracic deposition mechanisms) and characterization of airborne allergic triggers with a focus on PM<sub>2.5</sub> (particulate matter with diameter smaller than 2.5 microns), especially nanoparticles.</span></p>