Grant: Research Tools and Instruments - Category 1 (<$150,000)
University of Toronto
$150,000.00
A Roll-to-Roll (R2R) Manufacturing Facility for High-Throughput Fabrication of Paper Digital Microfluidic Devices
FY 2014-15
Summary
We propose to develop portable microfluidic analysis tools for pre-term and post-term screening of mothers and neonates for infectious diseases (congenital rubella syndrome) and inborn disorders (fetal alcohol spectrum) in vulnerable populations in Viet Nam and Canada, respectively. These methods rely on ""digital microfluidics"" and the proposals leverage our recent innovation that allows for ultra-low-cost fabrication of digital microfluidic devices by inkjet printing on paper. We submit this off-cycle NSERC RTI application as part of a recently awarded 2015 E.W.R. Steacie Fellowship to assemble a custom Roll-to-Roll (R2R) manufacturing facility for high-throughput microfluidic device fabrication. The proposed work breaks into three categories: (i) analytical method development, (ii) manufacturing method development and characterization, and (iii) characterization of throughput, uniformity, and scale. For (i) we will refine the designated assays (for rubella infection surveillance and for fetal alcohol spectrum disorder screening) and implement them in the field (which requires access to thousands of validated devices). For (ii), we will assemble a slotted dye-roller deposition system to fabricate paper DMF devices, characterized by AFM, SEM, and contact angle measurements. For (iii), we will establish a rigorous quality control framework in which electrical characterization of each device is logged into bar-codes generated post-manufacture. This work will establish Canada as the international leader in high-throughput fabrication of paper digital microfluidic devices. The ultimate goal of portable, paper digital microfluidic tests for field-applications is an important one, which will contribute to improved health outcomes in Canada and around the world.
Program
Research Tools and Instruments - Category 1 (<$150,000)
Recipient
Location
Ontario, Canada
Recipient Type
Academia
Type
Grant
Source
NSERC's Awards Data
As published
Application id
476772-2015
Name nom
Wheeler, Aaron
Department département
Chemistry (St. George Campus)
Organization id
31
Institution établissement
University of Toronto
Province en
Ontario
Province fr
Ontario
Country en
CANADA
Country fr
CANADA
Fiscal year exercice financier
2014
Competition year année de concours
2015
Award amount
150000
Program id
EQPEQ
Program name en
Research Tools and Instruments - Category 1 (<$150,000)
Program name fr
Outils et instruments de recherche - catégorie 1 (<150 000$)
Group en
Discovery grants programs
Group fr
Programmes de subventions à la découverte
Committee code
1504
Committee name en
Chemistry
Committee name fr
Chimie
Area of application code
1211
Area of application group en
Advancement of knowledge
Area of application group fr
Avancement des connaissances
Area of application en
Medical and health sciences
Area of application fr
Sciences médicales et de la santé
Research subject code
3500
Research subject group en
Analytical chemistry
Research subject group fr
Chimie analytique
Research subject en
Analytical chemistry
Research subject fr
Chimie analytique
Partie
1
Nb partie
1
Application title
A Roll-to-Roll (R2R) Manufacturing Facility for High-Throughput Fabrication of Paper Digital Microfluidic Devices
Keyword
NSERC
Application summary
We propose to develop portable microfluidic analysis tools for pre-term and post-term screening of mothers and neonates for infectious diseases (congenital rubella syndrome) and inborn disorders (fetal alcohol spectrum) in vulnerable populations in Viet Nam and Canada, respectively. These methods rely on ""digital microfluidics"" and the proposals leverage our recent innovation that allows for ultra-low-cost fabrication of digital microfluidic devices by inkjet printing on paper. We submit this off-cycle NSERC RTI application as part of a recently awarded 2015 E.W.R. Steacie Fellowship to assemble a custom Roll-to-Roll (R2R) manufacturing facility for high-throughput microfluidic device fabrication. The proposed work breaks into three categories: (i) analytical method development, (ii) manufacturing method development and characterization, and (iii) characterization of throughput, uniformity, and scale. For (i) we will refine the designated assays (for rubella infection surveillance and for fetal alcohol spectrum disorder screening) and implement them in the field (which requires access to thousands of validated devices). For (ii), we will assemble a slotted dye-roller deposition system to fabricate paper DMF devices, characterized by AFM, SEM, and contact angle measurements. For (iii), we will establish a rigorous quality control framework in which electrical characterization of each device is logged into bar-codes generated post-manufacture. This work will establish Canada as the international leader in high-throughput fabrication of paper digital microfluidic devices. The ultimate goal of portable, paper digital microfluidic tests for field-applications is an important one, which will contribute to improved health outcomes in Canada and around the world.