Grant: Engage Grants Program
Ryerson University
$25,000.00
Seismic Analysis of Super Frame Structure Design for High-Rise Building
FY 2017-18
Summary
As a response to ever denser cities, high rise buildings have become increasingly popular and are growing tallerthan ever. In addition, there is also a developing trend to use modularization that minimizes the constructionschedule and thereby reduces costs. A new efficient structural system for high rise building has been developedcalled the Super Frame (SF). SF structures divide a building structural system into primary and secondarystructures. The primary frames of the SF system are composed of vertical legs in each corner of the buildingwhich are linked by horizontal diaphragm elements at about every 10 to 20 floors. The primary frames resist allvertical, wind, and seismic forces as an exterior structure since the vertical elements are concentrated in thecorner areas of the building, maximizing resistance to the wind and seismic forces. The SF concept has beenrecently used in Asia and the Middle East [1]. However, for such buildings to be built in Canada, they mustconform to Canadian Building Code requirements [2] to ensure their serviceability limit state and ultimate limitstate design under high wind and earthquake loads. The total lateral deformation of the high rise must be underthe Canadian safety limits stated by the code to ensure safety and smooth operation of the high rise building'selevators; these benefits will, in turn, be passed onto rate paying customers.BAH Enterprises is an expert in the field of structural engineering for industrial projects with special emphasison powers stations, power plants (gas, coal, nuclear, wind and solar), electrical transmission projects, andindustrial buildings. BAH is interested in using a combined SF system of High Strength Steel (HSS) framesfilled with Ultra High-Performance Concrete (UHPC) for industrial buildings, as they offer numerousadvantages over other design structures, including lower costs, and more efficient use of space. BAH hasinvestigated the use of such SF designs for industrial buildings, but a lack a sufficient design model,particularly seismic modelling, has prevented practical implementation in projects thus far.
Program
Engage Grants Program
Recipient
Location
Ontario, Canada
Recipient Type
Academia
Type
Grant
Source
NSERC's Awards Data
As published
Application id
514919-2017
Name nom
Marzouk, Hesham
Department département
Civil Engineering
Organization id
43
Institution établissement
Ryerson University
Province en
Ontario
Province fr
Ontario
Country en
CANADA
Country fr
CANADA
Fiscal year exercice financier
2017
Competition year année de concours
2017
Award amount
25000
Program id
EGP
Program name en
Engage Grants Program
Program name fr
Programme de subventions d'engagement partenariat
Group en
Research partnerships programs
Group fr
Programmes de partenariat
Committee code
1553
Committee name en
Ontario Internal Decision Committee
Committee name fr
Comité de décision interne pour l'Ontario
Area of application code
1001
Area of application group en
Northern development
Area of application group fr
Développement du nord
Area of application en
Construction, transportation and communications
Area of application fr
Construction, transports et communications
Research subject code
1000
Research subject group en
Civil engineering
Research subject group fr
Génie civil
Research subject en
Civil engineering
Research subject fr
Génie civil
Partie
1
Nb partie
1
Application title
Seismic Analysis of Super Frame Structure Design for High-Rise Building
Keyword
NSERC
Application summary
As a response to ever denser cities, high rise buildings have become increasingly popular and are growing tallerthan ever. In addition, there is also a developing trend to use modularization that minimizes the constructionschedule and thereby reduces costs. A new efficient structural system for high rise building has been developedcalled the Super Frame (SF). SF structures divide a building structural system into primary and secondarystructures. The primary frames of the SF system are composed of vertical legs in each corner of the buildingwhich are linked by horizontal diaphragm elements at about every 10 to 20 floors. The primary frames resist allvertical, wind, and seismic forces as an exterior structure since the vertical elements are concentrated in thecorner areas of the building, maximizing resistance to the wind and seismic forces. The SF concept has beenrecently used in Asia and the Middle East [1]. However, for such buildings to be built in Canada, they mustconform to Canadian Building Code requirements [2] to ensure their serviceability limit state and ultimate limitstate design under high wind and earthquake loads. The total lateral deformation of the high rise must be underthe Canadian safety limits stated by the code to ensure safety and smooth operation of the high rise building'selevators; these benefits will, in turn, be passed onto rate paying customers.BAH Enterprises is an expert in the field of structural engineering for industrial projects with special emphasison powers stations, power plants (gas, coal, nuclear, wind and solar), electrical transmission projects, andindustrial buildings. BAH is interested in using a combined SF system of High Strength Steel (HSS) framesfilled with Ultra High-Performance Concrete (UHPC) for industrial buildings, as they offer numerousadvantages over other design structures, including lower costs, and more efficient use of space. BAH hasinvestigated the use of such SF designs for industrial buildings, but a lack a sufficient design model,particularly seismic modelling, has prevented practical implementation in projects thus far.