Grant: Idea to Innovation
University of Toronto
$14,775.00
Market Assessment for an innovative method to self-calibrate manipulator kinematic and sensor extrinsic**parameters
FY 2018-19
Summary
Collaborative robots, or cobots, are machines designed to work alongside humans in shared spaces. Many*cobots are mobile, and incorporate lightweight, person-safe robotic arms for manipulation tasks. These*(mobile) manipulators need to be correctly calibrated to ensure accurate and reliable operation. Calibration*typically involved determining sensor extrinsic parameters (i.e., external sensor pose relative to the manipulator*base) and manipulator kinematic parameters (e.g., joint biases and link length offsets). Calibration parameters*will often change over a robot's lifetime due to, for example, general wear and tear.*We have developed an innovative method for manipulator self-calibration using contact sensing. The method,*based on point cloud registration, can be applied to determine sensor extrinsic and manipulator kinematic*parameters. Requisite point cloud maps are generated from external visual or depth camera data, and by*monitoring end-effector contact with surfaces in the environment using a force-torque or tactile sensor and an*impedance controller. The process uses on-board hardware exclusively and does not rely on any external*measurement devices, fiducial markers, or calibration rigs; further, it is fully automatic in the general case.*This self-calibration method will very substantially reduce the costs of deploying person-safe, collaborative*manipulator systems, by decreasing or eliminating the need for human-in-the-loop maintenance and*adjustment. A wide range of robot application domains, from manufacturing to services, will benefit from*deploying the technology. This proposal seeks funding for a market assessment, to identify opportunities for*commercialization (within Canada), improving Canadian competitiveness in an emerging, critical market*sector with tremendous growth potential.
Program
Idea to Innovation
Recipient
Location
Ontario, Canada
Recipient Type
Academia
Type
Grant
Source
NSERC's Awards Data
As published
Application id
523435-2018
Name nom
Kelly, Jonathan
Department département
Aerospace Studies, Institute for
Organization id
31
Institution établissement
University of Toronto
Province en
Ontario
Province fr
Ontario
Country en
CANADA
Country fr
CANADA
Fiscal year exercice financier
2018
Competition year année de concours
2018
Award amount
14775
Program id
I2IPJ
Program name en
Idea to Innovation
Program name fr
De l'idée à l'innovation
Group en
Research partnerships programs
Group fr
Programmes de partenariat
Committee code
96
Committee name en
RPP Internal Decision Cttee
Committee name fr
Cté de décision interne - PPR
Area of application code
500
Area of application group en
Manufacturing processes and products
Area of application group fr
Procédés et produits industriels
Area of application en
Manufacturing processes and products
Area of application fr
Procédés et produits industriels
Research subject code
2600
Research subject group en
Robotics
Research subject group fr
Robotique
Research subject en
Robotics
Research subject fr
Robotique
Partie
1
Nb partie
1
Application title
Market Assessment for an innovative method to self-calibrate manipulator kinematic and sensor extrinsic**parameters
Keyword
NSERC
Application summary
Collaborative robots, or cobots, are machines designed to work alongside humans in shared spaces. Many*cobots are mobile, and incorporate lightweight, person-safe robotic arms for manipulation tasks. These*(mobile) manipulators need to be correctly calibrated to ensure accurate and reliable operation. Calibration*typically involved determining sensor extrinsic parameters (i.e., external sensor pose relative to the manipulator*base) and manipulator kinematic parameters (e.g., joint biases and link length offsets). Calibration parameters*will often change over a robot's lifetime due to, for example, general wear and tear.*We have developed an innovative method for manipulator self-calibration using contact sensing. The method,*based on point cloud registration, can be applied to determine sensor extrinsic and manipulator kinematic*parameters. Requisite point cloud maps are generated from external visual or depth camera data, and by*monitoring end-effector contact with surfaces in the environment using a force-torque or tactile sensor and an*impedance controller. The process uses on-board hardware exclusively and does not rely on any external*measurement devices, fiducial markers, or calibration rigs; further, it is fully automatic in the general case.*This self-calibration method will very substantially reduce the costs of deploying person-safe, collaborative*manipulator systems, by decreasing or eliminating the need for human-in-the-loop maintenance and*adjustment. A wide range of robot application domains, from manufacturing to services, will benefit from*deploying the technology. This proposal seeks funding for a market assessment, to identify opportunities for*commercialization (within Canada), improving Canadian competitiveness in an emerging, critical market*sector with tremendous growth potential.