Performance assessment of reinforced concrete structures
FY 2012-13
Summary
A reinforced concrete structure designed according to code standards will typically meet strength and serviceability criteria in a safe and reasonably efficient manner. Situations often arise, however, where a more accurate assessment of the structure's strength, safety and expected response is required. This is particularly true if the structure is subjected to uncommon or extreme loads (perhaps not explicitly considered in the original design), if the codes used for the design have been revised or superseded, or if the structure is deteriorating and in need of rehabilitation. Today, with our aging infrastructure and with the increased necessity to consider extreme loads, the need exists for tools providing advanced assessment capabilities. Common commercial software packages are of little use in this regard because they typically fail to capture the influences of various second-order mechanisms unique to reinforced concrete.
The experimental and theoretical research proposed represents a continuation of a tightly focused effort towards developing state-of-the-art analysis tools. Achievements to-date include well-recognized behaviour models for reinforced concrete (e.g., Modified Compression Field Theory) and a suite of advanced nonlinear finite element analysis (NLFEA) programs (i.e., VecTor). Building on this foundation, the proposed research is aimed at formulating improved simulation models for accurately assessing the performance of concrete structures under normal and extreme loadings. The emphasis will be on development of practical tools applicable to the challenges faced by designers today.
The attention paid to performance modelling (e.g., post-peak ductility) and rehabilitation chronology (e.g., effects of residual stresses and damage) will contribute to the timely and novel nature of the work. So, too, will the use of unique testing facilities such as the Panel Element Tester (for the fibre reinforced concrete panel tests), the new Large-Scale Impact Simulator (for slab impact tests), and the new Structural Fire Test Facility at NRC (for the column fire tests).
Program
Discovery Grants Program - Individual
Recipient
Location
Ontario, Canada
Recipient Type
Academia
Type
Grant
Source
NSERC's Awards Data
As published
Application id
92969-2010
Name nom
Vecchio, Frank
Department département
Civil Engineering
Organization id
31
Institution établissement
University of Toronto
Province en
Ontario
Province fr
Ontario
Country en
CANADA
Country fr
CANADA
Fiscal year exercice financier
2012
Competition year année de concours
2010
Award amount
24000
Program id
RGPIN
Program name en
Discovery Grants Program - Individual
Program name fr
Programme de subventions à la découverte - individuelles
Group en
Discovery grants programs
Group fr
Programmes de subventions à la découverte
Committee code
1509
Committee name en
Civil, Industrial and Systems Engineering
Committee name fr
Génie civil, industriel et des systèmes
Area of application code
601
Area of application group en
Construction, urban and rural planning
Area of application group fr
Construction, urbanisme et aménagement rural
Area of application en
Structural engineering
Area of application fr
Génie des charpentes
Research subject code
1103
Research subject group en
Structural engineering
Research subject group fr
Génie des structures
Research subject en
Concrete structures
Research subject fr
Structures en béton
Partie
3
Nb partie
5
Application title
Performance assessment of reinforced concrete structures
Keyword
NSERC
Application summary
A reinforced concrete structure designed according to code standards will typically meet strength and serviceability criteria in a safe and reasonably efficient manner. Situations often arise, however, where a more accurate assessment of the structure's strength, safety and expected response is required. This is particularly true if the structure is subjected to uncommon or extreme loads (perhaps not explicitly considered in the original design), if the codes used for the design have been revised or superseded, or if the structure is deteriorating and in need of rehabilitation. Today, with our aging infrastructure and with the increased necessity to consider extreme loads, the need exists for tools providing advanced assessment capabilities. Common commercial software packages are of little use in this regard because they typically fail to capture the influences of various second-order mechanisms unique to reinforced concrete.
The experimental and theoretical research proposed represents a continuation of a tightly focused effort towards developing state-of-the-art analysis tools. Achievements to-date include well-recognized behaviour models for reinforced concrete (e.g., Modified Compression Field Theory) and a suite of advanced nonlinear finite element analysis (NLFEA) programs (i.e., VecTor). Building on this foundation, the proposed research is aimed at formulating improved simulation models for accurately assessing the performance of concrete structures under normal and extreme loadings. The emphasis will be on development of practical tools applicable to the challenges faced by designers today.
The attention paid to performance modelling (e.g., post-peak ductility) and rehabilitation chronology (e.g., effects of residual stresses and damage) will contribute to the timely and novel nature of the work. So, too, will the use of unique testing facilities such as the Panel Element Tester (for the fibre reinforced concrete panel tests), the new Large-Scale Impact Simulator (for slab impact tests), and the new Structural Fire Test Facility at NRC (for the column fire tests).