Grant: Collaborative Research and Development Grants
University of Manitoba
$13,000.00
Line fault location in non-traditional HVDC systems
FY 2012-13
Summary
This research proposal is a collaborative research effort between the University of Manitoba and the Manitoba HVDC Research Centre to investigate new methods and technologies for transmission line fault location (LFL) in HVDC systems. The project also intends to use the same monitoring framework to investigate the detection of abnormal operating conditions.
When a permanent fault occurs in a HVDC transmission line, it is required to quickly locate the fault as accurately as possible. This is essential for carrying out necessary repairs in a timely fashion and minimizing possible power outages. The flashover at the fault point launches two waves that travel in opposite directions away from the fault. The existing LFL technology is based on capturing and analyzing the transients appearing at either end of the line. This travelling wave based LFL technology has served very well for the DC transmission systems using overhead (O/H) transmission line.
The number of cable, and combination cable and O/H HVDC systems is steadily growing. Further, the multiple terminal voltage source converter (VSC) HVDC systems are under consideration in many places, especially in the context of offshore wind farms and other renewable energy development projects. The existing LFL detects the arrival of waves by sensing the current spikes that pass through the surge capacitors located at the line terminals. This technique doesn't work well with cables due to high cable capacitance. The large DC capacitors on the VSC-HVDC schemes also have an effect similar to that of the cable capacitance. The existing fault location is strictly for two terminal systems. New signal processing techniques such as wavelet transformation
and intelligent systems have a clear potential to offer technical solutions that will improve the detection and location of line faults in non-traditional HVDC configurations. This research intends to explore this possibility and develop effective fault location algorithms, and implement them in a prototype LFL.
Program
Collaborative Research and Development Grants
Recipient
Location
Manitoba, Canada
Recipient Type
Academia
Type
Grant
Source
NSERC's Awards Data
As published
Application id
394757-2009
Name nom
Rajapakse, Athula
Department département
Electrical and Computer Engineering
Organization id
19
Institution établissement
University of Manitoba
Province en
Manitoba
Province fr
Manitoba
Country en
CANADA
Country fr
CANADA
Fiscal year exercice financier
2012
Competition year année de concours
2009
Award amount
13000
Program id
CRDPJ
Program name en
Collaborative Research and Development Grants
Program name fr
Subventions de recherche et développement coopérative
Group en
Research partnerships programs
Group fr
Programmes de partenariat
Committee code
96
Committee name en
RPP Internal Decision Cttee
Committee name fr
Cté de décision interne - PPR
Area of application code
304
Area of application group en
Energy resources
Area of application group fr
Ressources d'énergie
Area of application en
Electrical energy
Area of application fr
Énergie électrique
Research subject code
2501
Research subject group en
Electrical and electronic engineering
Research subject group fr
Génie électrique et électronique
Research subject en
Power systems
Research subject fr
Réseaux électriques
Partie
4
Nb partie
4
Application title
Line fault location in non-traditional HVDC systems
Keyword
NSERC
Application summary
This research proposal is a collaborative research effort between the University of Manitoba and the Manitoba HVDC Research Centre to investigate new methods and technologies for transmission line fault location (LFL) in HVDC systems. The project also intends to use the same monitoring framework to investigate the detection of abnormal operating conditions.
When a permanent fault occurs in a HVDC transmission line, it is required to quickly locate the fault as accurately as possible. This is essential for carrying out necessary repairs in a timely fashion and minimizing possible power outages. The flashover at the fault point launches two waves that travel in opposite directions away from the fault. The existing LFL technology is based on capturing and analyzing the transients appearing at either end of the line. This travelling wave based LFL technology has served very well for the DC transmission systems using overhead (O/H) transmission line.
The number of cable, and combination cable and O/H HVDC systems is steadily growing. Further, the multiple terminal voltage source converter (VSC) HVDC systems are under consideration in many places, especially in the context of offshore wind farms and other renewable energy development projects. The existing LFL detects the arrival of waves by sensing the current spikes that pass through the surge capacitors located at the line terminals. This technique doesn't work well with cables due to high cable capacitance. The large DC capacitors on the VSC-HVDC schemes also have an effect similar to that of the cable capacitance. The existing fault location is strictly for two terminal systems. New signal processing techniques such as wavelet transformation
and intelligent systems have a clear potential to offer technical solutions that will improve the detection and location of line faults in non-traditional HVDC configurations. This research intends to explore this possibility and develop effective fault location algorithms, and implement them in a prototype LFL.