Grant: Engage Grants Program
University of Toronto
$25,000.00
Development of chemical oxygen demand sensor using Au enhanced TiO2 nanostructures
FY 2013-14
Summary
Water is recognised to be one of the key problems of this millenia. Key will be developing treatment technologies that can clean wastewater - critical to the success of this approach is on-line monitoring of water quality. This project concerns developing a means for on-line testing of wastewater quality during treatment. Current approaches typically extract a sample of water and test it off-line to assess the parameters of treatment. This is time consuming and slow, and does not allow for process automation. Chemical oxygen demand (COD) is a measure of the oxygen (mg O2) consumed per litre of water containing organics. COD is one of the most commonly used measures of wastewater quality. The conventional method for determining COD is a tedious approach requiring reagents containing hazardous material (i.e. Mercury, sulfuric acid), a digestion reactor, and a spectrophotometer. The wastewater must first be combined with the reagents in order to oxidize the organic material present, and then digested for two hours in the reactor for the oxidation process to be completed. Our proposal concerns using a photo-electrochemical cell based on Au particle enhanced titania nanostructures to determine the COD. Using this approach, one can potentially measure current and correlate it with COD. The proposed structures are based on our published work using nanoparticles to enhance the local field and hence enhance photo-catalytic performance, enabling much more sensitive measurements of COD. Our partner JNE Chemicals is a wastewater treatment division of the JNE group of companies. Their mandate is to provide wastewater treatment chemicals, equipment and processes to industrial clients in Canada and the rest of the world. JNE is committed to exploring the development of this technology with us as a potential complement to their existing wastewater assessment technologies.
Program
Engage Grants Program
Recipient
Location
Ontario, Canada
Recipient Type
Academia
Type
Grant
Source
NSERC's Awards Data
As published
Application id
452508-2013
Name nom
Ruda, Harry
Department département
Materials Science and Engineering
Organization id
31
Institution établissement
University of Toronto
Province en
Ontario
Province fr
Ontario
Country en
CANADA
Country fr
CANADA
Fiscal year exercice financier
2013
Competition year année de concours
2013
Award amount
25000
Program id
EGP
Program name en
Engage Grants Program
Program name fr
Programme de subventions d'engagement partenariat
Group en
Research partnerships programs
Group fr
Programmes de partenariat
Committee code
1553
Committee name en
Ontario Internal Decision Committee
Committee name fr
Comité de décision interne pour l'Ontario
Area of application code
702
Area of application group en
Transportation systems and services
Area of application group fr
Services et systèmes de transport
Area of application en
Water
Area of application fr
Maritime
Research subject code
2001
Research subject group en
Materials science and technology
Research subject group fr
Science et technologie des matériaux
Research subject en
Materials structure, properties and testing
Research subject fr
Structure, propriétés et essais des matériaux
Partie
1
Nb partie
1
Application title
Development of chemical oxygen demand sensor using Au enhanced TiO2 nanostructures
Keyword
NSERC
Application summary
Water is recognised to be one of the key problems of this millenia. Key will be developing treatment technologies that can clean wastewater - critical to the success of this approach is on-line monitoring of water quality. This project concerns developing a means for on-line testing of wastewater quality during treatment. Current approaches typically extract a sample of water and test it off-line to assess the parameters of treatment. This is time consuming and slow, and does not allow for process automation. Chemical oxygen demand (COD) is a measure of the oxygen (mg O2) consumed per litre of water containing organics. COD is one of the most commonly used measures of wastewater quality. The conventional method for determining COD is a tedious approach requiring reagents containing hazardous material (i.e. Mercury, sulfuric acid), a digestion reactor, and a spectrophotometer. The wastewater must first be combined with the reagents in order to oxidize the organic material present, and then digested for two hours in the reactor for the oxidation process to be completed. Our proposal concerns using a photo-electrochemical cell based on Au particle enhanced titania nanostructures to determine the COD. Using this approach, one can potentially measure current and correlate it with COD. The proposed structures are based on our published work using nanoparticles to enhance the local field and hence enhance photo-catalytic performance, enabling much more sensitive measurements of COD. Our partner JNE Chemicals is a wastewater treatment division of the JNE group of companies. Their mandate is to provide wastewater treatment chemicals, equipment and processes to industrial clients in Canada and the rest of the world. JNE is committed to exploring the development of this technology with us as a potential complement to their existing wastewater assessment technologies.