Canada Spends Logo

Explore our Budget 2026 analysis

Grant: Discovery Grants Program - Individual

Université de Sherbrooke

$24,700.00

Improvements in polymer gel dosimetry: towards absolute and high spatial resolution dosimetry

FY 2007-08

Summary
Polymer gel dosimetry offer the unique possibility of recording radiation dose distributions in three dimensions and with a high spatial resolution. This capacity is crudely required by modern radiotherapy techniques including intensity-modulated radiation treatment, stereotactic radiosurgery and brachytherapy. Monomers initially dispersed in a gelatin matrix polymerize to an extent related to the incident radiation dose. Thus, the information on the absorbed radiation dose is encoded into the polymer gel by stable polymer clusters whose number depend on the dose. Common practice in polymer gel dosimetry is to derive a calibration curve of T2 (a parameter determined by magnetic resonance imaging, MRI) versus dose from small polymer gel samples irradiated to known doses. But the polymerization reaction is exothermic and the rate of polymerization depends on the temperature. Thus, temperature flow to the environment of the irradiated gel will influence the amount of polymer formed and, by consequent, the apparent absorbed dose determined by MRI. Our preliminary results show that the value of T2 depends on the diameter of a cylindrical container filled with polymer gel and irradiated to a given dose. Different thermal environments for the calibration vials and a phantom of interest is the most probable source of discrepancy between the expected dose distribution and that determined with polymer gel dosimetry. We propose to study systematically the effects of temperature during polymerization in order to determine an optimized calibration procedure. Besides thermal effects that can lead to inaccurate doses, long acquisition times could represent a stumbling block for MRI-polymer gel dosimetry. We propose to develop a fast image acquistion method (dual echo fast spin echo) that would reduce the imaging time from 8 hours to 30 minutes. Success of this project could be expected to improve significantly the absolute accuracy and the usability of MRI-polymer dosimetry.
Program
Discovery Grants Program - Individual
Location
Quebec, Canada
Recipient Type
Academia
Type
Grant
Source
NSERC's Awards Data

As published

Application id
326994-2006
Name nom
Lepage, Martin
Department département
Médecine nucléaire et radiobiologie
Organization id
68
Institution établissement
Université de Sherbrooke
Province en
Québec
Province fr
Québec
Country en
CANADA
Country fr
CANADA
Fiscal year exercice financier
2007
Competition year année de concours
2006
Award amount
24700
Program id
RGPIN
Program name en
Discovery Grants Program - Individual
Program name fr
Programme de subventions à la découverte - individuelles
Group en
Discovery grants programs
Group fr
Programmes de subventions à la découverte
Committee code
29
Committee name en
General Physics
Committee name fr
Physique générale
Area of application code
1211
Area of application group en
Advancement of knowledge
Area of application group fr
Avancement des connaissances
Area of application en
Medical and health sciences
Area of application fr
Sciences médicales et de la santé
Research subject code
9000
Research subject group en
Medical sciences
Research subject group fr
Sciences médicales
Research subject en
Medical sciences
Research subject fr
Sciences médicales
Partie
2
Nb partie
5
Application title
Improvements in polymer gel dosimetry: towards absolute and high spatial resolution dosimetry
Keyword
NA
Application summary
Polymer gel dosimetry offer the unique possibility of recording radiation dose distributions in three dimensions and with a high spatial resolution. This capacity is crudely required by modern radiotherapy techniques including intensity-modulated radiation treatment, stereotactic radiosurgery and brachytherapy. Monomers initially dispersed in a gelatin matrix polymerize to an extent related to the incident radiation dose. Thus, the information on the absorbed radiation dose is encoded into the polymer gel by stable polymer clusters whose number depend on the dose. Common practice in polymer gel dosimetry is to derive a calibration curve of T2 (a parameter determined by magnetic resonance imaging, MRI) versus dose from small polymer gel samples irradiated to known doses. But the polymerization reaction is exothermic and the rate of polymerization depends on the temperature. Thus, temperature flow to the environment of the irradiated gel will influence the amount of polymer formed and, by consequent, the apparent absorbed dose determined by MRI. Our preliminary results show that the value of T2 depends on the diameter of a cylindrical container filled with polymer gel and irradiated to a given dose. Different thermal environments for the calibration vials and a phantom of interest is the most probable source of discrepancy between the expected dose distribution and that determined with polymer gel dosimetry. We propose to study systematically the effects of temperature during polymerization in order to determine an optimized calibration procedure. Besides thermal effects that can lead to inaccurate doses, long acquisition times could represent a stumbling block for MRI-polymer gel dosimetry. We propose to develop a fast image acquistion method (dual echo fast spin echo) that would reduce the imaging time from 8 hours to 30 minutes. Success of this project could be expected to improve significantly the absolute accuracy and the usability of MRI-polymer dosimetry.