Grant: Discovery Grants Program - Individual
University of Ottawa
$66,000.00
A microfluidic platform for foodborne pathogenic bacteria detections
FY 2022-23
Summary
Outbreaks of foodborne diseases in recent years have led to the growth in demand for rapid, sensitive, and high-throughput methods and instrumentation for foodborne pathogens from food safety inspection authorities and food industries. A low-cost, robust, reliable and high-throughput pathogen detection platform can meet this increasing demand and allow food safety authorities to quickly respond to events such as foodborne disease outbreaks and bioterrorist attacks on our food supply chains. To this end, this research program is to develop a sensitive and low cost microfludics-based detection system that can circumvent the need for culture enrichment process and complete the whole testing of real-world foods within a short period of time. The proposed program integrates sample preparation and sample detection on-chip functionalities. It includes a separator to remove large food particles from the homogenized real-world food sample, a concentrator to remove liquid from the sample, and a detector for efficient capture and detection of target bacteria. As such, an input sample can be processed and subsequently analyzed in this continuous flow fashion within the system. For the current Discovery Grant (DG) application, the main objective is to develop an ultra sensitive microfluidic device that offers both sensitive and rapid detections. To achieve this, we propose to surface modify the microfluidic channel walls with dendrimers and conjugate target bacteria-specific aptamers. This will not only reduce the background signals due to non-specific bindings to the microchannel walls, but also provide multiple reaction sites to subsequently attach bacteria capturing aptamers. Studies will be advanced to investigate aptamers with different types of linkers at different linkage length to the anchoring surfaces. To further enhance detection, rolling circle amplification (RCA) signal intensifications will also be used, effectively enhancing detection signals. Finally, microfluidics flow patterns will be studied to improve detection efficiency. Anticipated significance of the work: The proposed detection system is novel in that it offers not only rapid and sensitive detections, but also possibilities to integrate with other microfluidic on-chip functionalities, such as separator and concentrators. The proposed studies is a key component of the overall proposed detection system. If successfully implemented, the fully integrated detection platform will significantly reduce detection time and lower detection cost, thereby allowing safety authorities to extend their testing coverage and frequencies and playing more proactive roles in identifying possible contaminations and suspicious activities.
Program
Discovery Grants Program - Individual
Recipient
Location
Ontario, Canada
Recipient Type
Academia
Type
Grant
Source
NSERC's Awards Data
As published
Application id
RGPIN-2018-06370
Name nom
Cao, Xudong
Department département
Chemical and Biological Engineering - Génie chimique et biologique
Organization id
28
Institution établissement
University of Ottawa
Province en
Ontario
Province fr
Ontario
Country en
CANADA
Country fr
CANADA
Fiscal year exercice financier
2022
Competition year année de concours
2018
Award amount
66000
Program id
RGPIN
Program name en
Discovery Grants Program - Individual
Program name fr
Programme de subventions à la découverte - individuelles
Group en
DISCOVERY RESEARCH
Group fr
RECHERCHE AXÉE SUR LA DÉCOUVERTE
Committee code
1511
Committee name en
Materials and Chemical Engineering
Committee name fr
Génie chimique et des matériaux
Area of application code
1102
Area of application group en
Health, education and social services
Area of application group fr
Santé publique, éducation et services sociaux
Area of application en
Biomedical engineering
Area of application fr
Génie biomédical
Research subject code
1800
Research subject group en
Chemical engineering
Research subject group fr
Génie chimique
Research subject en
Chemical engineering
Research subject fr
Génie chimique
Installment
inst:5;6
Partie
2
Nb partie
6
Application title
A microfluidic platform for foodborne pathogenic bacteria detections
Application summary
Outbreaks of foodborne diseases in recent years have led to the growth in demand for rapid, sensitive, and high-throughput methods and instrumentation for foodborne pathogens from food safety inspection authorities and food industries. A low-cost, robust, reliable and high-throughput pathogen detection platform can meet this increasing demand and allow food safety authorities to quickly respond to events such as foodborne disease outbreaks and bioterrorist attacks on our food supply chains. To this end, this research program is to develop a sensitive and low cost microfludics-based detection system that can circumvent the need for culture enrichment process and complete the whole testing of real-world foods within a short period of time. The proposed program integrates sample preparation and sample detection on-chip functionalities. It includes a separator to remove large food particles from the homogenized real-world food sample, a concentrator to remove liquid from the sample, and a detector for efficient capture and detection of target bacteria. As such, an input sample can be processed and subsequently analyzed in this continuous flow fashion within the system. For the current Discovery Grant (DG) application, the main objective is to develop an ultra sensitive microfluidic device that offers both sensitive and rapid detections. To achieve this, we propose to surface modify the microfluidic channel walls with dendrimers and conjugate target bacteria-specific aptamers. This will not only reduce the background signals due to non-specific bindings to the microchannel walls, but also provide multiple reaction sites to subsequently attach bacteria capturing aptamers. Studies will be advanced to investigate aptamers with different types of linkers at different linkage length to the anchoring surfaces. To further enhance detection, rolling circle amplification (RCA) signal intensifications will also be used, effectively enhancing detection signals. Finally, microfluidics flow patterns will be studied to improve detection efficiency. Anticipated significance of the work: The proposed detection system is novel in that it offers not only rapid and sensitive detections, but also possibilities to integrate with other microfluidic on-chip functionalities, such as separator and concentrators. The proposed studies is a key component of the overall proposed detection system. If successfully implemented, the fully integrated detection platform will significantly reduce detection time and lower detection cost, thereby allowing safety authorities to extend their testing coverage and frequencies and playing more proactive roles in identifying possible contaminations and suspicious activities.