Grant: Engage Grants Program
Ryerson University
$25,000.00
Effect of tensile modulus of GFRP on shrinkage and temperature reinforcement requirements in liquid containing structures
FY 2015-16
Summary
Fiber reinforced polymers (FRP) are composite materials made of fibers embedded in a polymeric resin. They were introduced as an alternative replacement for steel reinforcement. Electromagnetic interface and steel corrosion could be prevented by FRP reinforcement due to their nonmagnetic and non-corrosive nature. There has been a widespread use of fiber reinforced polymers (FRPs) as reinforcing composite bars for concrete structures over the past decade. Other than being corrosion resistant, there are many advantages of using such reinforcing bars especially glass FRPs (GFRPs) over the conventional reinforcement due to enhanced properties, cost-effectiveness, among many others. For structures exposed to aggressive environmental situations including liquid containing structures (CLCS) and marine structures, the alkalinity of concrete is reduced by its exposure to salts, moisture, temperature and chlorides leading to steel corrosion. The process of
corrosion will lead to concrete deterioration and lack of serviceability. In order to prevent corrosion and deterioration, engineers started using epoxy-coated bars and GFRPs later on. Using GFRP as a replacement for steel reinforcement for CLCS is a fairly new topic. Both Canadian and American standards for design of FRP reinforced structures (CSA S806-12 and ACI 440.1R-06) briefly mention on the minimum reinforcement for controlling temperature and shrinkage reinforcement. A comprehensive study is proposed here to address this issue. This study is aimed to investigate the parameters that influence the temperature and shrinkage reinforcement and in particular the effect of different types of GFRPs in terms of tensile modulus. It is also proposed to provide guidelines for structures reinforced with GFRP bars to limit the crack width to an
acceptable level.
Program
Engage Grants Program
Recipient
Location
Ontario, Canada
Recipient Type
Academia
Type
Grant
Source
NSERC's Awards Data
As published
Application id
491551-2015
Name nom
Kianoush, Reza
Department département
Civil Engineering
Organization id
43
Institution établissement
Ryerson University
Province en
Ontario
Province fr
Ontario
Country en
CANADA
Country fr
CANADA
Fiscal year exercice financier
2015
Competition year année de concours
2015
Award amount
25000
Program id
EGP
Program name en
Engage Grants Program
Program name fr
Programme de subventions d'engagement partenariat
Group en
Research partnerships programs
Group fr
Programmes de partenariat
Committee code
1553
Committee name en
Ontario Internal Decision Committee
Committee name fr
Comité de décision interne pour l'Ontario
Area of application code
603
Area of application group en
Construction, urban and rural planning
Area of application group fr
Construction, urbanisme et aménagement rural
Area of application en
Construction methods
Area of application fr
Méthodes de construction
Research subject code
1103
Research subject group en
Structural engineering
Research subject group fr
Génie des structures
Research subject en
Concrete structures
Research subject fr
Structures en béton
Partie
1
Nb partie
1
Application title
Effect of tensile modulus of GFRP on shrinkage and temperature reinforcement requirements in liquid containing structures
Keyword
NSERC
Application summary
Fiber reinforced polymers (FRP) are composite materials made of fibers embedded in a polymeric resin. They were introduced as an alternative replacement for steel reinforcement. Electromagnetic interface and steel corrosion could be prevented by FRP reinforcement due to their nonmagnetic and non-corrosive nature. There has been a widespread use of fiber reinforced polymers (FRPs) as reinforcing composite bars for concrete structures over the past decade. Other than being corrosion resistant, there are many advantages of using such reinforcing bars especially glass FRPs (GFRPs) over the conventional reinforcement due to enhanced properties, cost-effectiveness, among many others. For structures exposed to aggressive environmental situations including liquid containing structures (CLCS) and marine structures, the alkalinity of concrete is reduced by its exposure to salts, moisture, temperature and chlorides leading to steel corrosion. The process of
corrosion will lead to concrete deterioration and lack of serviceability. In order to prevent corrosion and deterioration, engineers started using epoxy-coated bars and GFRPs later on. Using GFRP as a replacement for steel reinforcement for CLCS is a fairly new topic. Both Canadian and American standards for design of FRP reinforced structures (CSA S806-12 and ACI 440.1R-06) briefly mention on the minimum reinforcement for controlling temperature and shrinkage reinforcement. A comprehensive study is proposed here to address this issue. This study is aimed to investigate the parameters that influence the temperature and shrinkage reinforcement and in particular the effect of different types of GFRPs in terms of tensile modulus. It is also proposed to provide guidelines for structures reinforced with GFRP bars to limit the crack width to an
acceptable level.