Grant: Discovery Grants Program - Individual
Lakehead University
$28,000.00
Polycrystalline Lead Oxide (PbO) photoconductor: physics and application in direct conversion x-ray medical imaging detectors
FY 2019-20
Summary
Direct conversion x-ray detectors with amorphous selenium (a-Se) layer as x-ray-to-charge transducers revolutionized radiation medical imaging. Indeed, a-Se mammographic detectors show breast image quality superior to other existing commercial detectors. ***Although a-Se properties fit applications in the mammographic energy range, for general radiographic and fluoroscopic applications a-Se has to be replaced by higher Z (atomic number) material. Therefore there is a need for a new material to realize the advantages of direct conversion methods in the diagnostic energy range. This need is addressed here: the objective of the proposed research program is to extend the advances of direct conversion x-ray detectors to fluoroscopic and radiographic applications on the basis of the most promising photoconductor material, namely Polycrystalline Lead Oxide (PbO). The new Lead Oxide Photoconductor technology will achieve higher sensitivity and improved spatial resolution over existing commercial indirect conversion methods. ***PbO has enormous potential for applications in radiographic and fluoroscopic imaging. It has two distinct advantages over a-Se: ***(1) it has higher x-ray detection efficiency than a-Se due to its higher Z and thus permits effective absorption of higher energy x-rays with thinner layer, and ***(2) it has lower electron-hole pair creation energy, and hence a higher x-ray-to-charge conversion gain.***However, PbO photoconductive layers are still experimental-they have not yet achieved conversion efficiency as high as the theoretical limit, and at the present stage of the technology, PbO layers have not yet shown adequate temporal behavior for fluoroscopic applications. Overcoming these challenges requires a comprehensive program on PbO physics and material science to understand the preparation-?fabrication-property relationships in this material and to optimize PbO technology based on this knowledge. The proposed program aims to transfer an improved PbO technology into Active Matrix Flat Panel Imagers (AMFPI) for fluoroscopy and low-cost X-ray light valve (XLV) detectors for radiography. ***The development of PbO-based detector technology is an important scientific and engineering accomplishment in the continuing development of digital x-ray imaging systems. In particular, PbO-based detectors have greater sensitivity at lower x-ray exposures. This has the core benefit of either reducing the incident x-ray dose to acquire a diagnostic image, and thereby improve the overall safety of general radiography and interventional procedures, or to improve disease detectability at typical x-ray exposures. As such, the proposed program will ultimately benefit healthcare in Canada and worldwide. **
Program
Discovery Grants Program - Individual
Recipient
Location
Ontario, Canada
Recipient Type
Academia
Type
Grant
Source
NSERC's Awards Data
As published
Application id
RGPIN-2015-04532
Name nom
Reznik, Alla
Department département
Physics
Organization id
25
Institution établissement
Lakehead University
Province en
Ontario
Province fr
Ontario
Country en
CANADA
Country fr
CANADA
Fiscal year exercice financier
2019
Competition year année de concours
2015
Award amount
28000
Program id
RGPIN
Program name en
Discovery Grants Program - Individual
Program name fr
Programme de subventions à la découverte - individuelles
Group en
DISCOVERY RESEARCH
Group fr
RECHERCHE AXÉE SUR LA DÉCOUVERTE
Committee code
1505
Committee name en
Physics
Committee name fr
Physique
Area of application code
1200
Area of application group en
Advancement of knowledge
Area of application group fr
Avancement des connaissances
Area of application en
Advancement of knowledge
Area of application fr
Avancement des connaissances
Research subject code
2001
Research subject group en
Materials science and technology
Research subject group fr
Science et technologie des matériaux
Research subject en
Materials structure, properties and testing
Research subject fr
Structure, propriétés et essais des matériaux
Installment
inst:5 - 5
Partie
5
Nb partie
5
Application title
Polycrystalline Lead Oxide (PbO) photoconductor: physics and application in direct conversion x-ray medical imaging detectors
Keyword
NSERC
Application summary
Direct conversion x-ray detectors with amorphous selenium (a-Se) layer as x-ray-to-charge transducers revolutionized radiation medical imaging. Indeed, a-Se mammographic detectors show breast image quality superior to other existing commercial detectors. ***Although a-Se properties fit applications in the mammographic energy range, for general radiographic and fluoroscopic applications a-Se has to be replaced by higher Z (atomic number) material. Therefore there is a need for a new material to realize the advantages of direct conversion methods in the diagnostic energy range. This need is addressed here: the objective of the proposed research program is to extend the advances of direct conversion x-ray detectors to fluoroscopic and radiographic applications on the basis of the most promising photoconductor material, namely Polycrystalline Lead Oxide (PbO). The new Lead Oxide Photoconductor technology will achieve higher sensitivity and improved spatial resolution over existing commercial indirect conversion methods. ***PbO has enormous potential for applications in radiographic and fluoroscopic imaging. It has two distinct advantages over a-Se: ***(1) it has higher x-ray detection efficiency than a-Se due to its higher Z and thus permits effective absorption of higher energy x-rays with thinner layer, and ***(2) it has lower electron-hole pair creation energy, and hence a higher x-ray-to-charge conversion gain.***However, PbO photoconductive layers are still experimental-they have not yet achieved conversion efficiency as high as the theoretical limit, and at the present stage of the technology, PbO layers have not yet shown adequate temporal behavior for fluoroscopic applications. Overcoming these challenges requires a comprehensive program on PbO physics and material science to understand the preparation-?fabrication-property relationships in this material and to optimize PbO technology based on this knowledge. The proposed program aims to transfer an improved PbO technology into Active Matrix Flat Panel Imagers (AMFPI) for fluoroscopy and low-cost X-ray light valve (XLV) detectors for radiography. ***The development of PbO-based detector technology is an important scientific and engineering accomplishment in the continuing development of digital x-ray imaging systems. In particular, PbO-based detectors have greater sensitivity at lower x-ray exposures. This has the core benefit of either reducing the incident x-ray dose to acquire a diagnostic image, and thereby improve the overall safety of general radiography and interventional procedures, or to improve disease detectability at typical x-ray exposures. As such, the proposed program will ultimately benefit healthcare in Canada and worldwide. **