Grant: Collaborative Research and Development Grants
University of Guelph
$100,000.00
Investigating the performance degradation of centrifugal pumps
FY 2017-18
Summary
While the amount of energy used for pumping varies depending on a number of factors, the energy consumption in pumping systems accounts for approximately 10% of the world's electrical energy demand. Also, the life-cycle cost of running a pump is often far outweighs their capital cost and the pump inefficiencies usually account for up to approximately 25 per cent of potential energy savings in pumping systems. It therefore stands to reason that energy efficiency and evaluating performance degradation of pumps should be an important consideration to the operation of variety of systems including but not limited to energy production, cooling, heating, food processing, water distribution, etc. Several factors play a significant role in performance degradation of pumps such as vibration, hydraulic factor including cavitation, recirculation, axial thrust, radial thrust, and pressure pulsations, corrosion, erosion and maintenance. Different methods were developed to monitor degradation in pumps including: vibration spectral analysis, modal analysis, acoustic emission analysis, and motor current or power analysis. Historical trending of process parameters such as temperature, pressure, flow rates, and infrared imaging are also used. However, very limited studies were developed to evaluate the effect of operation and varying the system load on pump performance over the entire life of the pump. Also, evaluating the effect of multi-degradation mechanism on the pump performance has not been studies before. Therefore, the objective of this study is to experimentally investigate the performance degradation of different type of pumps of interest to Xylem Co. under different operating conditions. Also, the automation system analysis will be used to develop a diagnostic tool for predictive maintenance. The gained knowledge from this research will enable better design of the pumps and develop a better operation control. This will not only save energy consumption in the pumping system, but also will improve the pump reliability, and reduced life cycle costs, which will directly benefit the Canadian economy.
Program
Collaborative Research and Development Grants
Recipient
Location
Ontario, Canada
Recipient Type
Academia
Type
Grant
Source
NSERC's Awards Data
As published
Application id
506193-2016
Name nom
Ahmed, Wael
Department département
Engineering, School of
Organization id
24
Institution établissement
University of Guelph
Province en
Ontario
Province fr
Ontario
Country en
CANADA
Country fr
CANADA
Fiscal year exercice financier
2017
Competition year année de concours
2016
Award amount
100000
Program id
CRDPJ
Program name en
Collaborative Research and Development Grants
Program name fr
Subventions de recherche et développement coopérative
Group en
Research partnerships programs
Group fr
Programmes de partenariat
Committee code
96
Committee name en
RPP Internal Decision Cttee
Committee name fr
Cté de décision interne - PPR
Area of application code
1206
Area of application group en
Advancement of knowledge
Area of application group fr
Avancement des connaissances
Area of application en
Engineering
Area of application fr
Génie
Research subject code
2100
Research subject group en
Mechanical engineering
Research subject group fr
Génie mécanique
Research subject en
Mechanical engineering
Research subject fr
Génie mécanique
Partie
1 & 2
Nb partie
2
Application title
Investigating the performance degradation of centrifugal pumps
Keyword
NSERC
Application summary
While the amount of energy used for pumping varies depending on a number of factors, the energy consumption in pumping systems accounts for approximately 10% of the world's electrical energy demand. Also, the life-cycle cost of running a pump is often far outweighs their capital cost and the pump inefficiencies usually account for up to approximately 25 per cent of potential energy savings in pumping systems. It therefore stands to reason that energy efficiency and evaluating performance degradation of pumps should be an important consideration to the operation of variety of systems including but not limited to energy production, cooling, heating, food processing, water distribution, etc. Several factors play a significant role in performance degradation of pumps such as vibration, hydraulic factor including cavitation, recirculation, axial thrust, radial thrust, and pressure pulsations, corrosion, erosion and maintenance. Different methods were developed to monitor degradation in pumps including: vibration spectral analysis, modal analysis, acoustic emission analysis, and motor current or power analysis. Historical trending of process parameters such as temperature, pressure, flow rates, and infrared imaging are also used. However, very limited studies were developed to evaluate the effect of operation and varying the system load on pump performance over the entire life of the pump. Also, evaluating the effect of multi-degradation mechanism on the pump performance has not been studies before. Therefore, the objective of this study is to experimentally investigate the performance degradation of different type of pumps of interest to Xylem Co. under different operating conditions. Also, the automation system analysis will be used to develop a diagnostic tool for predictive maintenance. The gained knowledge from this research will enable better design of the pumps and develop a better operation control. This will not only save energy consumption in the pumping system, but also will improve the pump reliability, and reduced life cycle costs, which will directly benefit the Canadian economy.