Canada Spends Logo

Explore our Budget 2026 analysis

Grant: Discovery Grants Program - Individual

Concordia University

$56,000.00

Photoconductors for medical imaging detectors: materials issues and device designs

FY 2024-25

Summary
The flat-panel active matrix imagers (FPAMI) are the most successful digital X-ray detectors for medical imaging such as mammography and general radiography. The FPAMIs are generally either phosphor based (indirect conversion) or photoconductor based (direct conversion, presently amorphous selenium, a-Se, based). The a-Se based detectors produce much sharper images than the indirect conversion detectors. Although the FPAMIs have high potential to reduce the radiation dose, they operate far from the fundamental quantum-noise level. The dose levels at quantum-noise limited detectors can be much lower than that used by currently available FPAMIs. Recently, the organic perovskite (e.g., polycrystalline methylammonium lead triiodide) photoconductors have shown good potential to be used in direct conversion detectors for low dose and lost cost medical X-ray imaging detectors. Its X-ray sensitivity is almost an order better than a-Se. The organic perovskite can be uniformly deposited over large area using a printing method. This method is cheaper than the high temperature-process needed to prepare CsI or a-Se, and should reduce the cost of FPAMI system. However, organic perovskite X-ray detectors can't be commercialized unitil overcoming few scientific challenges such as obtaining low dark current, high resolution, free of image lag and ghosting, and long-term material and device stability. Very low-dose medical X-ray imaging could also be achieved by utilizing carrier multiplication (e.g., avalanche process) at a very high electric field in a-Se layer for higher charge signal, which could improve the signal to noise ratio. The applicant's research program will endeavor to develop low-dose and low-cost medical X-ray imaging detectors using organic perovskites and avalanche a-Se. The research objective includes 1) investigation of charge carrier generation and transport mechanisms in organic perovskites photoconductors and a-Se, 2) investigation of appropriate multilayer perovskite detector structure that shows very low dark current together with high resolution and negligible image lag and ghosting, 3) Investigation of carrier transport mechanisms through various layers and hence determination of the optimum design of multilayer structure for a-Se avalanche X-ray detectors, and 4) study of long term stability. The development of novel organic perovskite X-ray detectors in this proposal can make a big difference to medical imaging. It can greatly lower the radiation dose used in fluoroscopy and general X-ray radiography. It will also open the door to a new class of low-cost organic perovskite large-area X-ray sensors and fuel innovation in other X-ray imaging techniques, such as computed tomography. Another novelty of this proposal is to design multilayer a-Se avalanche detector structure for very low dose and high resolution direct conversion X-ray imaging. This research will be beneficial to Canada's R&D efforts in medical digital imaging.
Program
Discovery Grants Program - Individual
Location
Quebec, Canada
Recipient Type
Academia
Type
Grant
Source
NSERC's Awards Data

As published

Application id
RGPIN-2019-05472
Name nom
Kabir, M. Zahangir
Department département
Electrical and Computer Engineering - Electrical and Computer Engineering
Organization id
70
Institution établissement
Concordia University
Province en
Québec
Province fr
Québec
Country en
CANADA
Country fr
CANADA
Fiscal year exercice financier
2024
Competition year année de concours
2019
Award amount
56000
Program id
RGPIN
Program name en
Discovery Grants Program - Individual
Program name fr
Programme de subventions à la découverte - individuelles
Group en
DISCOVERY RESEARCH
Group fr
RECHERCHE AXÉE SUR LA DÉCOUVERTE
Committee code
1510
Committee name en
Electrical and Computer Engineering
Committee name fr
Génie électrique et informatique
Area of application code
518
Area of application group en
Manufacturing processes and products
Area of application group fr
Procédés et produits industriels
Area of application en
Medical equipment and apparatus
Area of application fr
Appareils et instruments médicaux
Research subject code
2515
Research subject group en
Electrical and electronic engineering
Research subject group fr
Génie électrique et électronique
Research subject en
Electronic materials and components
Research subject fr
Matériels et composants électroniques
Field of research list names en
Not available
Field of research list names fr
Non disponible
Socioeconomic objective list names en
Not available
Socioeconomic objective list names fr
Non disponible
Application title
Photoconductors for medical imaging detectors: materials issues and device designs
Keywords
perovskite x-ray detectors; digital medical x-ray imaging; amorphous selenium detectors; semiconductor materials and devices; device theory and physics-based modeling; charge carrier transport and generation mechanisms; low dose and low cost medical x-ray imaging; dark current and detector structure; signal quanta and noise; x-ray sensitivity/resolution/dqe
Application summary
The flat-panel active matrix imagers (FPAMI) are the most successful digital X-ray detectors for medical imaging such as mammography and general radiography. The FPAMIs are generally either phosphor based (indirect conversion) or photoconductor based (direct conversion, presently amorphous selenium, a-Se, based). The a-Se based detectors produce much sharper images than the indirect conversion detectors. Although the FPAMIs have high potential to reduce the radiation dose, they operate far from the fundamental quantum-noise level. The dose levels at quantum-noise limited detectors can be much lower than that used by currently available FPAMIs. Recently, the organic perovskite (e.g., polycrystalline methylammonium lead triiodide) photoconductors have shown good potential to be used in direct conversion detectors for low dose and lost cost medical X-ray imaging detectors. Its X-ray sensitivity is almost an order better than a-Se. The organic perovskite can be uniformly deposited over large area using a printing method. This method is cheaper than the high temperature-process needed to prepare CsI or a-Se, and should reduce the cost of FPAMI system. However, organic perovskite X-ray detectors can't be commercialized unitil overcoming few scientific challenges such as obtaining low dark current, high resolution, free of image lag and ghosting, and long-term material and device stability. Very low-dose medical X-ray imaging could also be achieved by utilizing carrier multiplication (e.g., avalanche process) at a very high electric field in a-Se layer for higher charge signal, which could improve the signal to noise ratio. The applicant's research program will endeavor to develop low-dose and low-cost medical X-ray imaging detectors using organic perovskites and avalanche a-Se. The research objective includes 1) investigation of charge carrier generation and transport mechanisms in organic perovskites photoconductors and a-Se, 2) investigation of appropriate multilayer perovskite detector structure that shows very low dark current together with high resolution and negligible image lag and ghosting, 3) Investigation of carrier transport mechanisms through various layers and hence determination of the optimum design of multilayer structure for a-Se avalanche X-ray detectors, and 4) study of long term stability. The development of novel organic perovskite X-ray detectors in this proposal can make a big difference to medical imaging. It can greatly lower the radiation dose used in fluoroscopy and general X-ray radiography. It will also open the door to a new class of low-cost organic perovskite large-area X-ray sensors and fuel innovation in other X-ray imaging techniques, such as computed tomography. Another novelty of this proposal is to design multilayer a-Se avalanche detector structure for very low dose and high resolution direct conversion X-ray imaging. This research will be beneficial to Canada's R&D efforts in medical digital imaging.