Grant: Research Tools and Instruments - Category 1 (<$150,000)
University of Manitoba
$29,301.00
Tools to investigate transepithelial ammonia transports
FY 2010-11
Summary
In my NSERC funded research program the mechanisms responsible for the epithelial transport of ammonia, a highly toxic metabolic waste product from protein metabolism, is investigated with the focus on amphibians and invertebrates including planarians, insects, crustaceans, annelids and nematodes. For a thorough study of transport processes an integrative approach is imperative. The requested tool is a highly versatile 6-channel Voltage-Current Clamp/Ussing chamber system. This system allows the determination of the electrophysiological properties of a given transport epithelium including the tissue-generated transepithelial voltage difference, the produced electrical current and the ion permeability (conductance) but can simultaneously also be used for transepithelial flux measurements of specific ions and solutes. The Ussing chamber itself allows the usage of a wide variety of different tissue holders with different apertures (ca. 1 cm2 to 1 mm2). It is therefore suitable for the investigation of epithelia of different sizes, so that e.g. the intestine of butterfly larvae or frog skin can be mounted and investigated. Since several sets of custom-made tissue holders are already at hand for this system, in this application, holders for mounting frog skin (0.9 cm2) and split crab gill lamella (1 mm2) are requested. The requested equipment fills the gap between my studies using the living animal and investigations on the molecular level by allowing the examination of transport kinetics, electric properties, and transport mechanisms and their regulation in the transporting epithelium employing a ""near in-vivo"" set-up. The same model as the requested equipment is an essential element in my research and involved in several current projects which are conducted by 7 HQP. However, the apparatus in place right now is on loan from the German Research Foundation (DFG) and must be returned to Germany immediately. Therefore the requested system is necessary to ensure the continuation of my research program, my competitiveness as a researcher on a national and international level and also to allow my students to finish their ongoing projects in a timely manner.
Program
Research Tools and Instruments - Category 1 (<$150,000)
Recipient
Location
Manitoba, Canada
Recipient Type
Academia
Type
Grant
Source
NSERC's Awards Data
As published
Application id
407922-2011
Name nom
Weihrauch, Dirk
Department département
Biological Sciences
Organization id
19
Institution établissement
University of Manitoba
Province en
Manitoba
Province fr
Manitoba
Country en
CANADA
Country fr
CANADA
Fiscal year exercice financier
2010
Competition year année de concours
2011
Award amount
29301
Program id
EQPEQ
Program name en
Research Tools and Instruments - Category 1 (<$150,000)
Program name fr
Outils et instruments de recherche - catégorie 1 (<150 000$)
Group en
Discovery grants programs
Group fr
Programmes de subventions à la découverte
Committee code
1502
Committee name en
Biological Systems and Functions
Committee name fr
Systèmes et fonctions biologiques
Area of application code
1201
Area of application group en
Advancement of knowledge
Area of application group fr
Avancement des connaissances
Area of application en
Life sciences (including biotechnology)
Area of application fr
Sciences de la vie (y compris biotechnologie)
Research subject code
5504
Research subject group en
Animal biology
Research subject group fr
Biologie animale
Research subject en
Animal physiology and metabolism
Research subject fr
Physiologie et métabolisme des animaux
Partie
1
Nb partie
1
Application title
Tools to investigate transepithelial ammonia transports
Keyword
NSERC
Application summary
In my NSERC funded research program the mechanisms responsible for the epithelial transport of ammonia, a highly toxic metabolic waste product from protein metabolism, is investigated with the focus on amphibians and invertebrates including planarians, insects, crustaceans, annelids and nematodes. For a thorough study of transport processes an integrative approach is imperative. The requested tool is a highly versatile 6-channel Voltage-Current Clamp/Ussing chamber system. This system allows the determination of the electrophysiological properties of a given transport epithelium including the tissue-generated transepithelial voltage difference, the produced electrical current and the ion permeability (conductance) but can simultaneously also be used for transepithelial flux measurements of specific ions and solutes. The Ussing chamber itself allows the usage of a wide variety of different tissue holders with different apertures (ca. 1 cm2 to 1 mm2). It is therefore suitable for the investigation of epithelia of different sizes, so that e.g. the intestine of butterfly larvae or frog skin can be mounted and investigated. Since several sets of custom-made tissue holders are already at hand for this system, in this application, holders for mounting frog skin (0.9 cm2) and split crab gill lamella (1 mm2) are requested. The requested equipment fills the gap between my studies using the living animal and investigations on the molecular level by allowing the examination of transport kinetics, electric properties, and transport mechanisms and their regulation in the transporting epithelium employing a ""near in-vivo"" set-up. The same model as the requested equipment is an essential element in my research and involved in several current projects which are conducted by 7 HQP. However, the apparatus in place right now is on loan from the German Research Foundation (DFG) and must be returned to Germany immediately. Therefore the requested system is necessary to ensure the continuation of my research program, my competitiveness as a researcher on a national and international level and also to allow my students to finish their ongoing projects in a timely manner.