Grant: Research Tools and Instruments - Category 1 (<$150,000)
Ryerson University
$52,904.00
The effects of local microclimatic conditions of highly urban environments on hygrothermal performance of building envelopes
FY 2007-08
Summary
The hourly weather data that are usually used as indicators of environmental loadings on building envelopes are not always sufficient. Studies show that accuracy of the heat-air-moisture (HAM) transfer simulations and calculated wind driven rain (WDR) amounts and intensities results are, to a large extent, determined by the time resolution of the meteorological input data (Blocken et al, Atmos. Environ. 2007, 41, 2335; Blocken and Carmeliet, J. Wind Eng. Industr. Aerodynamics, 2007, 95, 585). It is highly recommended that high-resolution data (e.g. 10-min data) be used for more accurate simulation results. In establishing her new research program at Ryerson that coincides with the development of Ryerson's newly approved Masters of Building Science (starting September 2008), this applicant is planning to include such data in studying HAM performance and WRD distribution on building envelopes, and further investigate such hypothesis. Specifically, this project will study the influence of microclimatic environmental loads that exists in urban downtown environment in the City of Toronto on hygrothermal performance of various exterior wall assemblies in real time, over at least 3 seasons, combining experimentation and simulation. It will compare results of HAM performance simulation based on high-resolution data acquired on site, simulation based on hourly data from the airport weather station and experimentation data. This project will provide training and research work for 7 Masters of Building Science students over 5 years, as well as opportunities for participation for several undergraduate students. The results of this research will contribute to expanding the knowledge on accuracy and appropriateness of weather data used in building performance simulation, a research question raised among researchers in Canada and worldwide.
Program
Research Tools and Instruments - Category 1 (<$150,000)
Recipient
Location
Ontario, Canada
Recipient Type
Academia
Type
Grant
Source
NSERC's Awards Data
As published
Application id
358817-2008
Name nom
Horvat, Miljana
Department département
Architectural Science
Organization id
43
Institution établissement
Ryerson University
Province en
Ontario
Province fr
Ontario
Country en
CANADA
Country fr
CANADA
Fiscal year exercice financier
2007
Competition year année de concours
2008
Award amount
52904
Program id
EQPEQ
Program name en
Research Tools and Instruments - Category 1 (<$150,000)
Program name fr
Outils et instruments de recherche - catégorie 1 (<150 000$)
Group en
Discovery grants programs
Group fr
Programmes de subventions à la découverte
Committee code
1061
Committee name en
Civil Engineering - A
Committee name fr
Génie civil - A
Area of application code
1200
Area of application group en
Advancement of knowledge
Area of application group fr
Avancement des connaissances
Area of application en
Advancement of knowledge
Area of application fr
Avancement des connaissances
Research subject code
7000
Research subject group en
Other studies in natural sciences and engineering
Research subject group fr
Autres études en sciences naturelles et en génie
Research subject en
Other studies in natural sciences and engineering
Research subject fr
Autres études en sciences naturelles et en génie
Partie
1
Nb partie
1
Application title
The effects of local microclimatic conditions of highly urban environments on hygrothermal performance of building envelopes
Keyword
NA
Application summary
The hourly weather data that are usually used as indicators of environmental loadings on building envelopes are not always sufficient. Studies show that accuracy of the heat-air-moisture (HAM) transfer simulations and calculated wind driven rain (WDR) amounts and intensities results are, to a large extent, determined by the time resolution of the meteorological input data (Blocken et al, Atmos. Environ. 2007, 41, 2335; Blocken and Carmeliet, J. Wind Eng. Industr. Aerodynamics, 2007, 95, 585). It is highly recommended that high-resolution data (e.g. 10-min data) be used for more accurate simulation results. In establishing her new research program at Ryerson that coincides with the development of Ryerson's newly approved Masters of Building Science (starting September 2008), this applicant is planning to include such data in studying HAM performance and WRD distribution on building envelopes, and further investigate such hypothesis. Specifically, this project will study the influence of microclimatic environmental loads that exists in urban downtown environment in the City of Toronto on hygrothermal performance of various exterior wall assemblies in real time, over at least 3 seasons, combining experimentation and simulation. It will compare results of HAM performance simulation based on high-resolution data acquired on site, simulation based on hourly data from the airport weather station and experimentation data. This project will provide training and research work for 7 Masters of Building Science students over 5 years, as well as opportunities for participation for several undergraduate students. The results of this research will contribute to expanding the knowledge on accuracy and appropriateness of weather data used in building performance simulation, a research question raised among researchers in Canada and worldwide.