Grant: Engage Grants Program
Carleton University
$25,000.00
Numerical and experimental investigations of a condenser fan add-on device
FY 2014-15
Summary
Vairtex Canada Inc. (Ottawa, ON) developed a de-swirling passive device unit to be added on top of the fans of industrial air-cooled condensers, which are normally installed at the rooftop of grocery stores as part of their refrigeration systems. Due to the simplistic design of the commonly used axial fans in these units, part of the heated flow coming from the condenser that passes through the fans will recirculate to the side and lower inlets of the unit. In addition, recirculation zones just above the fan, close to the axis of rotation, will also attract heated air back into the unit. The de-swirling passive device units redirect the flow upwards and minimize recirculation, thus improving the performance of the unit, at the same time reducing maintenance of the electrical motors that drive the fans by reducing overheating. Vairtex Canada Inc. is interested in partially optimizing its units (length size and angle of passive blades) for particular applications by applying computational tools and careful energy balance experiments of an actual size single-unit assembly. Fluid flow and temperature measurements will be performed using hotwire anemometry and thermocouples using a traverse system at the midplane of the flow downstream of the fan (with and without the Vairtex unit). An energy balance of the fan will be performed. This data will be used as boundary conditions for a numerical simulation using standard CFD (Computational Fluid Dynamics) techniques.
Program
Engage Grants Program
Recipient
Location
Ontario, Canada
Recipient Type
Academia
Type
Grant
Source
NSERC's Awards Data
As published
Application id
463712-2014
Name nom
Matida, Edgar
Department département
Mechanical & Aerospace Engineering
Organization id
23
Institution établissement
Carleton University
Province en
Ontario
Province fr
Ontario
Country en
CANADA
Country fr
CANADA
Fiscal year exercice financier
2014
Competition year année de concours
2014
Award amount
25000
Program id
EGP
Program name en
Engage Grants Program
Program name fr
Programme de subventions d'engagement partenariat
Group en
Research partnerships programs
Group fr
Programmes de partenariat
Committee code
1553
Committee name en
Ontario Internal Decision Committee
Committee name fr
Comité de décision interne pour l'Ontario
Area of application code
306
Area of application group en
Energy resources
Area of application group fr
Ressources d'énergie
Area of application en
Energy efficiency
Area of application fr
Efficacité énergétique
Research subject code
2200
Research subject group en
Fluid mechanics
Research subject group fr
Mécanique des fluides
Research subject en
Fluid mechanics
Research subject fr
Mécanique des fluides
Partie
1
Nb partie
1
Application title
Numerical and experimental investigations of a condenser fan add-on device
Keyword
NSERC
Application summary
Vairtex Canada Inc. (Ottawa, ON) developed a de-swirling passive device unit to be added on top of the fans of industrial air-cooled condensers, which are normally installed at the rooftop of grocery stores as part of their refrigeration systems. Due to the simplistic design of the commonly used axial fans in these units, part of the heated flow coming from the condenser that passes through the fans will recirculate to the side and lower inlets of the unit. In addition, recirculation zones just above the fan, close to the axis of rotation, will also attract heated air back into the unit. The de-swirling passive device units redirect the flow upwards and minimize recirculation, thus improving the performance of the unit, at the same time reducing maintenance of the electrical motors that drive the fans by reducing overheating. Vairtex Canada Inc. is interested in partially optimizing its units (length size and angle of passive blades) for particular applications by applying computational tools and careful energy balance experiments of an actual size single-unit assembly. Fluid flow and temperature measurements will be performed using hotwire anemometry and thermocouples using a traverse system at the midplane of the flow downstream of the fan (with and without the Vairtex unit). An energy balance of the fan will be performed. This data will be used as boundary conditions for a numerical simulation using standard CFD (Computational Fluid Dynamics) techniques.