Grant: Collaborative Research and Development Grants
McMaster University
$83,500.00
Development of a Fast Neutron Computed Tomography System for Non-Invasive Testing
FY 2021-22
Summary
This research grant aims to develop a novel computed tomography system which is capable of measuring 3-dimensional phasic distributions inside complex engineering structures. Phase-change phenomena greatly impact the physics in many engineering systems but direct measurement of the 3-dimensional phase field has historically involved intrusive measurements and/or may not be applied universally to systems that operate under boiling conditions at high pressure and temperatures. The industrial collaborator for this work is the CANDU Owners Group and their goal is to obtain measurements of the phase field inside a CANDU fuel string simulator where boiling occurs and pressures can exceed 10 MPa in order to generate data for model improvement and multi-phase computational fluid dynamics validation. A review of existing commercially available measurements has indicated that there is a need for new advancements in 3D non-destructive testing in this area with application to the nuclear industry as well as other sectors where phase change phenomena can occur. This project will develop a fast-neutron computed tomography (FCNT) system capable of imaging 3-dimensional phase-field distributions in complex geometries and involving thick pressure boundaries. The new technology development is possible today due to radical improvements in mobile nuetron generator technologies which have increased in neutron output from 1e7 to 1e10 over the last ten years. It integrates new developments in the area of accelerator based neutron generators, new Silicon-Photo multiplier (SiPM) technologies with existing CT schemes to obtain a new mobile system capable of meeting current and future R&D demands. The goal is to have the technology render distributions with 1cm or better resolution and scan times which are acceptable to industry (on the order of 1 hour as opposed to multiple hours or days required with some historical system). The work represents the first-of-its-kind technology in Canada and will have wide ranging applications across various R&D sectors in Canada.
Program
Collaborative Research and Development Grants
Recipient
Location
Ontario, Canada
Recipient Type
Academia
Type
Grant
Source
NSERC's Awards Data
As published
Application id
532146-2018
Name nom
Novog, David
Department département
Engineering Physics
Organization id
27
Institution établissement
McMaster University
Province en
Ontario
Province fr
Ontario
Country en
CANADA
Country fr
CANADA
Fiscal year exercice financier
2021
Competition year année de concours
2018
Award amount
83500
Program id
CRDPJ
Program name en
Collaborative Research and Development Grants
Program name fr
Subventions de recherche et développement coopérative
Group en
Research partnerships programs
Group fr
Programmes de partenariat
Committee code
96
Committee name en
RPP Internal Decision Cttee
Committee name fr
Cté de décision interne - PPR
Area of application code
515
Area of application group en
Manufacturing processes and products
Area of application group fr
Procédés et produits industriels
Area of application en
Instrumentation technology
Area of application fr
Technologie de l'instrumentation
Research subject code
2400
Research subject group en
Nuclear engineering
Research subject group fr
Génie nucléaire
Research subject en
Nuclear engineering
Research subject fr
Génie nucléaire
Installment
inst:5
Partie
1
Nb partie
5
Application title
Development of a Fast Neutron Computed Tomography System for Non-Invasive Testing
Keyword
NSERC
Application summary
This research grant aims to develop a novel computed tomography system which is capable of measuring 3-dimensional phasic distributions inside complex engineering structures. Phase-change phenomena greatly impact the physics in many engineering systems but direct measurement of the 3-dimensional phase field has historically involved intrusive measurements and/or may not be applied universally to systems that operate under boiling conditions at high pressure and temperatures. The industrial collaborator for this work is the CANDU Owners Group and their goal is to obtain measurements of the phase field inside a CANDU fuel string simulator where boiling occurs and pressures can exceed 10 MPa in order to generate data for model improvement and multi-phase computational fluid dynamics validation. A review of existing commercially available measurements has indicated that there is a need for new advancements in 3D non-destructive testing in this area with application to the nuclear industry as well as other sectors where phase change phenomena can occur. This project will develop a fast-neutron computed tomography (FCNT) system capable of imaging 3-dimensional phase-field distributions in complex geometries and involving thick pressure boundaries. The new technology development is possible today due to radical improvements in mobile nuetron generator technologies which have increased in neutron output from 1e7 to 1e10 over the last ten years. It integrates new developments in the area of accelerator based neutron generators, new Silicon-Photo multiplier (SiPM) technologies with existing CT schemes to obtain a new mobile system capable of meeting current and future R&D demands. The goal is to have the technology render distributions with 1cm or better resolution and scan times which are acceptable to industry (on the order of 1 hour as opposed to multiple hours or days required with some historical system). The work represents the first-of-its-kind technology in Canada and will have wide ranging applications across various R&D sectors in Canada.