Canada Spends Logo

Explore our Budget 2026 analysis

Grant: Engage Grants Program

Concordia University

$25,000.00

Airflow and thermal management analysis of vertical data center with thermosiphons by fire dynamics simulator

FY 2013-14

Summary
Data centers consumed 1.5% of the total electricity in 2006 in the North America. The information andcommunication technology (ICT) industry also accounts for about 2% of global CO2 emissions. Over 60% ofthe total electricity of a data center is typically used for the cooling from the chillers, running all year roundeven if outdoor temperatures are lower than indoor's. To reduce the data center energy consumption,VERT.COM, Inc. has invented an innovative standardized, prefabricated, vertical data center (VDC) system:the Siloctet PrefabTM. The system is able to deliver low temperature outside air directly to computer rackswhen the outdoor air is appropriate for cooling so no chiller operation is needed. However, concerns are raisedover increased levels of particulate and gaseous pollutants from the direct use of the outdoor air. This projectproposed to add a thermosiphon system to the Siloctet VDC module to still use ""free cooling"" withoutintroducing outside air directly to a data center so the outdoor pollutants are avoided. The new system uses aclosed-loop thermosiphon heat exchanger to bring the cooling energy inside a data center. To evaluate theenergy impact of the thermosiphon on a VDC system, this project focuses on computer modeling of airflowand thermal management in such a system by using the computational fluid dynamics software, fire dynamicssimulator, developed by the U.S. NIST where the applicant worked as a postdoctoral associate. The analysiscovers the location, the selection, and the effectiveness of the thermosihphon system in the VDC. Canada isknown for its cold climate. The proposed VDC with the thermosiphon system operates at its optimumconditions in Canadian climate, where there is long period of ""free cooling"" to achieve a huge energy savingpotential. This research initializes the collaboration between VERT.COM and Concordia University, which inthe long term can leads to a new product line of the company: a Siloctet Vertical Data Center module withthermosiphon technologies.
Program
Engage Grants Program
Location
Quebec, Canada
Recipient Type
Academia
Type
Grant
Source
NSERC's Awards Data

As published

Application id
459012-2013
Name nom
Wang, Liangzhu
Department département
Building, Civil and Environmental Engineering
Organization id
70
Institution établissement
Concordia University
Province en
Québec
Province fr
Québec
Country en
CANADA
Country fr
CANADA
Fiscal year exercice financier
2013
Competition year année de concours
2013
Award amount
25000
Program id
EGP
Program name en
Engage Grants Program
Program name fr
Programme de subventions d'engagement partenariat
Group en
Research partnerships programs
Group fr
Programmes de partenariat
Committee code
1552
Committee name en
Quebec Internal Decision Committee
Committee name fr
Comité de décision interne pour le Québec
Area of application code
306
Area of application group en
Energy resources
Area of application group fr
Ressources d'énergie
Area of application en
Energy efficiency
Area of application fr
Efficacité énergétique
Research subject code
2100
Research subject group en
Mechanical engineering
Research subject group fr
Génie mécanique
Research subject en
Mechanical engineering
Research subject fr
Génie mécanique
Partie
1
Nb partie
1
Application title
Airflow and thermal management analysis of vertical data center with thermosiphons by fire dynamics simulator
Keyword
NSERC
Application summary
Data centers consumed 1.5% of the total electricity in 2006 in the North America. The information andcommunication technology (ICT) industry also accounts for about 2% of global CO2 emissions. Over 60% ofthe total electricity of a data center is typically used for the cooling from the chillers, running all year roundeven if outdoor temperatures are lower than indoor's. To reduce the data center energy consumption,VERT.COM, Inc. has invented an innovative standardized, prefabricated, vertical data center (VDC) system:the Siloctet PrefabTM. The system is able to deliver low temperature outside air directly to computer rackswhen the outdoor air is appropriate for cooling so no chiller operation is needed. However, concerns are raisedover increased levels of particulate and gaseous pollutants from the direct use of the outdoor air. This projectproposed to add a thermosiphon system to the Siloctet VDC module to still use ""free cooling"" withoutintroducing outside air directly to a data center so the outdoor pollutants are avoided. The new system uses aclosed-loop thermosiphon heat exchanger to bring the cooling energy inside a data center. To evaluate theenergy impact of the thermosiphon on a VDC system, this project focuses on computer modeling of airflowand thermal management in such a system by using the computational fluid dynamics software, fire dynamicssimulator, developed by the U.S. NIST where the applicant worked as a postdoctoral associate. The analysiscovers the location, the selection, and the effectiveness of the thermosihphon system in the VDC. Canada isknown for its cold climate. The proposed VDC with the thermosiphon system operates at its optimumconditions in Canadian climate, where there is long period of ""free cooling"" to achieve a huge energy savingpotential. This research initializes the collaboration between VERT.COM and Concordia University, which inthe long term can leads to a new product line of the company: a Siloctet Vertical Data Center module withthermosiphon technologies.