Grant: Engage Grants Program
University of Waterloo
$25,000.00
Improved durability coils for transcranial magnetic stimulation
FY 2012-13
Summary
Repetitive transcranial magnetic stimulation (rTMS) is a non-invasive therapeutic technique which uses strong, pulsed magnetic fields to induce neural action potentials in the brain. This technology is FDA-approved for the treatment of depression. In a TMS treatment, short, high current pulses applied to a specialized coil generate a strong magnetic field which stimulates the neurons in specific areas of the brain. These pulses take a rapid toll on the coil due to heating effects and mechanical strain from the Lorentz forces produced from the switching magnetic field. Typical TMS coils have a lifetime of 2 million pulses, translating into 5 to 6 months of normal use. As well as being durable, coils must be relatively compact for ease of positioning, have a low enough inductance to allow rapid pulsing, and generate a very strong magnetic field (over 2T at the coil face) with high spatial selectivity for brain stimulation. The proposed research project investigates and develops new coil systems with improved durability, which will lower both the operating and treatment costs. The new coils will eventually be used in an improved rTMS system, currently under development by Neurogate Medical Systems, the industrial supporter of the proposed research. Coil heating is the most important factor affecting durability, and active cooling approaches are already incorporated into modern coils. Newer coil designs are using Litz wire because it can offer reduced heating compared conventional approaches. In this project, we seek new coil designs that offer reduced heating and which can accommodate efficient cooling. Coil patterns already exist which generate a magnetic field appropriate for TMS. The challenge becomes designing the Litz wire based coil and moving or removing windings from such designs in order to allow channels for coolant flow. This should be done in a manner that keeps the coil compact and maintains the required field characteristics. The proposed research will address the coil design from an electromagnetic perspective, prototype development, and test. Coil lifetime improvements ensuing from reduced coil heating and better cooling will give Neurogate a competitive edge in the TMS coil market.
Program
Engage Grants Program
Recipient
Location
Ontario, Canada
Recipient Type
Academia
Type
Grant
Source
NSERC's Awards Data
As published
Application id
431231-2012
Name nom
SafaviNaeini, Safieddin
Department département
Electrical & Computer Engineering
Organization id
33
Institution établissement
University of Waterloo
Province en
Ontario
Province fr
Ontario
Country en
CANADA
Country fr
CANADA
Fiscal year exercice financier
2012
Competition year année de concours
2012
Award amount
25000
Program id
EGP
Program name en
Engage Grants Program
Program name fr
Programme de subventions d'engagement partenariat
Group en
Research partnerships programs
Group fr
Programmes de partenariat
Committee code
1553
Committee name en
Ontario Internal Decision Committee
Committee name fr
Comité de décision interne pour l'Ontario
Area of application code
518
Area of application group en
Manufacturing processes and products
Area of application group fr
Procédés et produits industriels
Area of application en
Medical equipment and apparatus
Area of application fr
Appareils et instruments médicaux
Research subject code
2502
Research subject group en
Electrical and electronic engineering
Research subject group fr
Génie électrique et électronique
Research subject en
Electromagnetics
Research subject fr
Électromagnétisme
Partie
1
Nb partie
1
Application title
Improved durability coils for transcranial magnetic stimulation
Keyword
NSERC
Application summary
Repetitive transcranial magnetic stimulation (rTMS) is a non-invasive therapeutic technique which uses strong, pulsed magnetic fields to induce neural action potentials in the brain. This technology is FDA-approved for the treatment of depression. In a TMS treatment, short, high current pulses applied to a specialized coil generate a strong magnetic field which stimulates the neurons in specific areas of the brain. These pulses take a rapid toll on the coil due to heating effects and mechanical strain from the Lorentz forces produced from the switching magnetic field. Typical TMS coils have a lifetime of 2 million pulses, translating into 5 to 6 months of normal use. As well as being durable, coils must be relatively compact for ease of positioning, have a low enough inductance to allow rapid pulsing, and generate a very strong magnetic field (over 2T at the coil face) with high spatial selectivity for brain stimulation. The proposed research project investigates and develops new coil systems with improved durability, which will lower both the operating and treatment costs. The new coils will eventually be used in an improved rTMS system, currently under development by Neurogate Medical Systems, the industrial supporter of the proposed research. Coil heating is the most important factor affecting durability, and active cooling approaches are already incorporated into modern coils. Newer coil designs are using Litz wire because it can offer reduced heating compared conventional approaches. In this project, we seek new coil designs that offer reduced heating and which can accommodate efficient cooling. Coil patterns already exist which generate a magnetic field appropriate for TMS. The challenge becomes designing the Litz wire based coil and moving or removing windings from such designs in order to allow channels for coolant flow. This should be done in a manner that keeps the coil compact and maintains the required field characteristics. The proposed research will address the coil design from an electromagnetic perspective, prototype development, and test. Coil lifetime improvements ensuing from reduced coil heating and better cooling will give Neurogate a competitive edge in the TMS coil market.