Grant: Discovery Grants Program - Individual
University of Toronto
$59,000.00
Parallel Radiofrequency Transmission to Correct the Effects of Head Motion in Magnetic Resonance Neuroimages
FY 2023-24
Summary
Magnetic resonance imaging (MRI) is the main medical tool for visualizing the brain, but it is highly sensitive to the effects of head motion - causing image artifacts that can obscure clinically relevant features. The artifacts are complex in origin, difficult to remove, and still result in discarding considerable patient MRI data due to head motion, impacting healthcare costs and outcomes. Furthermore, as the spatial resolution of MRI continues to improve, artifacts are caused by ever smaller motions, making novel motion artifact suppression methods even more essential. This NSERC project will develop a method called "parallel radiofrequency transmission" (PTX) to suppress motion artifacts on clinical-grade MRI systems operating at 3 Tesla magnetic field strength. Developed in the mid-2000s, the PTX method consists of splitting the radiofrequency (RF) transmission chain into multiple channels, greatly increasing the degrees of freedom that can be used to excite magnetization from biological tissues - a critically important step in spatial encoding and formation of MR images. The PTX method is highly flexible, although it has not been used yet to tackle the head motion problem. In the project, PTX will be used for "adaptive MRI", whereby RF excitation pulses will be adjusted during imaging, compensating for multiple instrumental imperfections at the time of MRI data acquisition, including head motion and its effects on the spatial uniformity of RF transmission, of the main magnetic field, and of MRI signal reception. Dr. Graham has conceived this project based on his extensive work to correct motion artifacts in MRI and his experience conducting PTX research since 2015. Compared to standard MRI at 3 T, adaptive PTX MRI is hypothesized to reduce motion artifacts. The objectives are to: O1) create a robust position tracker, using two MRI-compatible video cameras aimed at the head and artificial intelligence (AI) to estimate rigid-body head motion; O2) augment the existing PTX platform in the lab to enable brain MRI with 16 channels; and O3) develop and validate adaptive PTX MRI in "phantom" test objects and human volunteers. This project lays the groundwork for advanced PTX tools on 3 T MRI systems and improved neuroimaging of the brain, with benefits to clinicians, researchers, the private sector and patients in Canada and internationally. This work will also be directly relevant to emerging medical-¬grade ultrahigh field systems operating at 7 T and above - where the spatial resolution gains make suppressing head motion artifacts even more important.
Program
Discovery Grants Program - Individual
Recipient
Location
Ontario, Canada
Recipient Type
Academia
Type
Grant
Source
NSERC's Awards Data
As published
Application id
RGPIN-2023-04408
Name nom
Graham, Simon
Department département
Physical Sciences/Sunnybrook Research Institute
Organization id
31
Institution établissement
University of Toronto
Province en
Ontario
Province fr
Ontario
Country en
CANADA
Country fr
CANADA
Fiscal year exercice financier
2023
Competition year année de concours
2023
Award amount
59000
Program id
RGPIN
Program name en
Discovery Grants Program - Individual
Program name fr
Programme de subventions à la découverte - individuelles
Group en
DISCOVERY RESEARCH
Group fr
RECHERCHE AXÉE SUR LA DÉCOUVERTE
Committee code
1505
Committee name en
Physics
Committee name fr
Physique
Area of application code
1102
Area of application group en
Health, education and social services
Area of application group fr
Santé publique, éducation et services sociaux
Area of application en
Biomedical engineering
Area of application fr
Génie biomédical
Research subject code
2518
Research subject group en
Electrical and electronic engineering
Research subject group fr
Instrumentation and measurements
Research subject en
Génie électrique et électronique
Research subject fr
Instrumentation et mesures
Application title
Parallel Radiofrequency Transmission to Correct the Effects of Head Motion in Magnetic Resonance Neuroimages
Keyword
Head Motion; Magnetic Resonance Imaging; Neuroimaging; Parallel Radiofrequency Transmission
Application summary
Magnetic resonance imaging (MRI) is the main medical tool for visualizing the brain, but it is highly sensitive to the effects of head motion - causing image artifacts that can obscure clinically relevant features. The artifacts are complex in origin, difficult to remove, and still result in discarding considerable patient MRI data due to head motion, impacting healthcare costs and outcomes. Furthermore, as the spatial resolution of MRI continues to improve, artifacts are caused by ever smaller motions, making novel motion artifact suppression methods even more essential. This NSERC project will develop a method called "parallel radiofrequency transmission" (PTX) to suppress motion artifacts on clinical-grade MRI systems operating at 3 Tesla magnetic field strength. Developed in the mid-2000s, the PTX method consists of splitting the radiofrequency (RF) transmission chain into multiple channels, greatly increasing the degrees of freedom that can be used to excite magnetization from biological tissues - a critically important step in spatial encoding and formation of MR images. The PTX method is highly flexible, although it has not been used yet to tackle the head motion problem. In the project, PTX will be used for "adaptive MRI", whereby RF excitation pulses will be adjusted during imaging, compensating for multiple instrumental imperfections at the time of MRI data acquisition, including head motion and its effects on the spatial uniformity of RF transmission, of the main magnetic field, and of MRI signal reception. Dr. Graham has conceived this project based on his extensive work to correct motion artifacts in MRI and his experience conducting PTX research since 2015. Compared to standard MRI at 3 T, adaptive PTX MRI is hypothesized to reduce motion artifacts. The objectives are to: O1) create a robust position tracker, using two MRI-compatible video cameras aimed at the head and artificial intelligence (AI) to estimate rigid-body head motion; O2) augment the existing PTX platform in the lab to enable brain MRI with 16 channels; and O3) develop and validate adaptive PTX MRI in "phantom" test objects and human volunteers. This project lays the groundwork for advanced PTX tools on 3 T MRI systems and improved neuroimaging of the brain, with benefits to clinicians, researchers, the private sector and patients in Canada and internationally. This work will also be directly relevant to emerging medical-¬grade ultrahigh field systems operating at 7 T and above - where the spatial resolution gains make suppressing head motion artifacts even more important.