Canada Spends Logo

Explore our Budget 2026 analysis

Grant: Engage Grants Program

University of Windsor

$25,000.00

Accurate calibration of x-ray imaging systems used for LAUE and stress measurement in single crystals.

FY 2011-12

Summary
Although the use of vision systems for nondestructive/non-contact stress measurement is becoming the method of choice in this industry, the obtained results often suffer from poor accuracy that prevent accurate measure undermine feature extraction. Hence, the accuracy of the measurements is the main challenge for the company current stress measurement apparatus. The main cause for this poor accuracy has to do with the use of the simple pinhole model for camera calibration, a good assumption for distortion-free situations. However, when very high accuracy is sought, as in this particular case, the simple pinhole camera model is not appropriate for calibration. As the main source of the problem as being the high nonlinear optical distortion, that is inherent to the lenses being used in the current image sensors, correcting these non-linear distortions is the first step to improving the calibration accuracy. This will allow to obtain better measurement results. Two possible solutions will be tested and compared for solving this problem. We will explore the automatic construction of a distortion-correction table using an accurate known pattern, possibly with structured light as the first option. Then, we will also explore the use of analytical solution where the calibration uses an augmented pinhole model that has extra nonlinear terms to account for the optical distortions.
Program
Engage Grants Program
Location
Ontario, Canada
Recipient Type
Academia
Type
Grant
Source
NSERC's Awards Data

As published

Application id
429079-2011
Name nom
Boufama, Boubakeur
Department département
Computer Science, School of
Organization id
37
Institution établissement
University of Windsor
Province en
Ontario
Province fr
Ontario
Country en
CANADA
Country fr
CANADA
Fiscal year exercice financier
2011
Competition year année de concours
2011
Award amount
25000
Program id
EGP
Program nane en
Engage Grants Program
Program name fr
Programme de subventions d'engagement partenariat
Group en
Research partnerships programs
Group fr
Programmes de partenariat
Committee code
1553
Committee name en
Ontario Internal Decision Committee
Committee name fr
Comité de décision interne pour l'Ontario
Area of application code
1206
Area of application group en
Advancement of knowledge
Area of application group fr
Avancement des connaissances
Area of application en
Engineering
Area of application fr
Génie
Research subject code
2603
Research subject group en
Robotics
Research subject group fr
Robotique
Research subject en
Computer vision
Research subject fr
Vision artificielle
Partie
1
Nb partie
1
Application title
Accurate calibration of x-ray imaging systems used for LAUE and stress measurement in single crystals.
Keyword
NSERC
Application summary
Although the use of vision systems for nondestructive/non-contact stress measurement is becoming the method of choice in this industry, the obtained results often suffer from poor accuracy that prevent accurate measure undermine feature extraction. Hence, the accuracy of the measurements is the main challenge for the company current stress measurement apparatus. The main cause for this poor accuracy has to do with the use of the simple pinhole model for camera calibration, a good assumption for distortion-free situations. However, when very high accuracy is sought, as in this particular case, the simple pinhole camera model is not appropriate for calibration. As the main source of the problem as being the high nonlinear optical distortion, that is inherent to the lenses being used in the current image sensors, correcting these non-linear distortions is the first step to improving the calibration accuracy. This will allow to obtain better measurement results. Two possible solutions will be tested and compared for solving this problem. We will explore the automatic construction of a distortion-correction table using an accurate known pattern, possibly with structured light as the first option. Then, we will also explore the use of analytical solution where the calibration uses an augmented pinhole model that has extra nonlinear terms to account for the optical distortions.
University of Windsor - $25,000 Grant (2011-12) | Canada Spends