Grant: Collaborative Research and Development Grants
Lakehead University
$20,000.00
Application of thermal mixing on sewer pipe inspection in high flows
FY 2019-20
Summary
Ongoing changes in land use and climate have shown that conventional wastewater systems will receive additional loading due to increased peak runoff and flooding events. In addition, the majority of wastewater systems were built during a rapid growth period and now require a continuous condition assessment. Sanitary sewer systems are a significant portion of a municipality's capital investment budget and annual operating budget. The City of Thunder Bay is responsible for conducting condition assessment of around 500 km of a sewer pipeline network. Conventional condition assessment methods like implementing closed circuit television (CCTV) are very labor intensive and expensive. The City of Thunder Bay is investing in practical research projects to find easily updated and cost-effective monitoring systems to acquire information about the quality and ageing of wastewater collection systems. The present proposal aims to conduct laboratory experiments to perform sensitivity analysis of thermography and using thermal sensors for condition assessment of wastewater collection systems using wireless technology. Thermal mapping techniques are proposed using both conventional temperature sensors and emerging thermal imaging cameras. In this project, a novel, self-contained wireless data collection system will be developed to dramatically reduce the costs of pipe assessment. Using a winter season model, where the average temperature of wastewater is around 25 degrees and underground water is approximately 3 degrees, data collection units can directly measure water temperature using a sensitive thermometer, and can record thermal images using sensitive infrared cameras to identify the position and magnitude of flow infiltration. The monitoring data from the operational units in the field testing will be validated with the thermal mixing theory. The outcome of this research project will offer the City of Thunder Bay and other municipalities in Canada a validated, integrated tether-less unit that can efficiently monitor the existing condition of pipelines in underground sewer systems.
Program
Collaborative Research and Development Grants
Recipient
Location
Ontario, Canada
Recipient Type
Academia
Type
Grant
Source
NSERC's Awards Data
As published
Application id
538895-2019
Name nom
Azimi, AmirHossein
Department département
Civil Engineering
Organization id
25
Institution établissement
Lakehead University
Province en
Ontario
Province fr
Ontario
Country en
CANADA
Country fr
CANADA
Fiscal year exercice financier
2019
Competition year année de concours
2019
Award amount
20000
Program id
CRDPJ
Program name en
Collaborative Research and Development Grants
Program name fr
Subventions de recherche et développement coopérative
Group en
RESEARCH PARTNERSHIPS
Group fr
PARTENARIATS DE RECHERCHE
Committee code
96
Committee name en
RPP Internal Decision Cttee
Committee name fr
Cté de décision interne - PPR
Area of application code
702
Area of application group en
Transportation systems and services
Area of application group fr
Services et systèmes de transport
Area of application en
Water
Area of application fr
Maritime
Research subject code
1007
Research subject group en
Civil engineering
Research subject group fr
Génie civil
Research subject en
Water resources and supply
Research subject fr
Ressources et approvisionnement en eau
Installment
inst:1 - 1
Partie
1
Nb partie
1
Application title
Application of thermal mixing on sewer pipe inspection in high flows
Keyword
NSERC
Application summary
Ongoing changes in land use and climate have shown that conventional wastewater systems will receive additional loading due to increased peak runoff and flooding events. In addition, the majority of wastewater systems were built during a rapid growth period and now require a continuous condition assessment. Sanitary sewer systems are a significant portion of a municipality's capital investment budget and annual operating budget. The City of Thunder Bay is responsible for conducting condition assessment of around 500 km of a sewer pipeline network. Conventional condition assessment methods like implementing closed circuit television (CCTV) are very labor intensive and expensive. The City of Thunder Bay is investing in practical research projects to find easily updated and cost-effective monitoring systems to acquire information about the quality and ageing of wastewater collection systems. The present proposal aims to conduct laboratory experiments to perform sensitivity analysis of thermography and using thermal sensors for condition assessment of wastewater collection systems using wireless technology. Thermal mapping techniques are proposed using both conventional temperature sensors and emerging thermal imaging cameras. In this project, a novel, self-contained wireless data collection system will be developed to dramatically reduce the costs of pipe assessment. Using a winter season model, where the average temperature of wastewater is around 25 degrees and underground water is approximately 3 degrees, data collection units can directly measure water temperature using a sensitive thermometer, and can record thermal images using sensitive infrared cameras to identify the position and magnitude of flow infiltration. The monitoring data from the operational units in the field testing will be validated with the thermal mixing theory. The outcome of this research project will offer the City of Thunder Bay and other municipalities in Canada a validated, integrated tether-less unit that can efficiently monitor the existing condition of pipelines in underground sewer systems.