Canada Spends Logo

Explore our Budget 2026 analysis

Grant: Research Tools and Instruments

University of Waterloo

$80,716.00

Transcranial Magnetic Stimulation System

FY 2015-16

Summary
Non-invasive brain stimulation techniques are essential for understanding neural mechanisms associated with neuroplasticity in the central nervous system (CNS). Neuroplasticity is the foundation for adaptation in the CNS associated with experience-dependent learning, sensori-motor integration and in the restoration of function following nervous system injury. Transcranial magnetic stimulation (TMS) is an effective, non-invasive brain stimulation method that involves passing current through a stimulator coil that generates a magnetic field perpendicular to the current flow. The magnetic field passes through the bone of the skull unimpeded and excites neurons in the cerebral cortex. Dr. Staines currently has a TMS unit (Medtronic / Magventure MagPro x100) that is reaching the end of its recommended lifespan (~ 10 years). The stimulation coils also require replacement every ~3-5 years. There are 2 specific coils required that allow stimulation in different frequency patterns. Such stimulation can be done with single or paired-pulse configurations to the cerebral cortex or in a repetitive mode requiring multiple stimuli to be delivered over a short time frame. One such pattern is termed theta burst stimulation (TBS) in which stimuli are delivered in burst patterns of 3 stimuli at 50 Hz delivered at a frequency of 5 Hz (theta) over a short period of time. This TBS can be delivered in different modes to either transiently excite or depress a specific area of the brain. The present request is for replacement of the current TMS system (MagPro) including 2 stimulation coils and replacement electroencephalography (EEG) caps to integrate with our current TMS and EEG (SynAmps2, Neuroscan, Compumedics) systems. This will allow the quantification of neuromodulation induced by the TMS both within and across individuals to be greatly enhanced. This is critical for studies of the neural mechanisms associated with sensorimotor neuroplasticity, cognitive neuroscience and oculomotor processes. The equipment will allow the continuation of ongoing work as well as the development of new collaborative teams. HQP from several Faculties (AHS, Science, Arts) will have access to training and use of the equipment. Equipment The equipment requested is the replacement of the current TMS system including 2 stimulation coils as well as an EMG interface module for a Magventure MagPro system. The MCF-B65 coil is a statically cooled coil capable of delivering many stimuli. It is specifically required for the repetitive stimulation studies. The MC-B70 allows more focal stimulation and is important for motor mapping studies. The quote for the TMS system including the necessary stimulation coils and the EMG interface module is $70,370 after in kind educational discounts. In addition to the stimulation coils, the request includes electrode caps necessary for studies of neuromodulation in response to repetitive TMS using TBS.
Program
Research Tools and Instruments
Location
Ontario, Canada
Recipient Type
Academia
Type
Grant
Source
NSERC's Awards Data

As published

Application id
RTI-2016-00051
Name nom
Staines, William
Department département
Kinesiology - Kinesiology
Organization id
33
Institution établissement
University of Waterloo
Province en
Ontario
Province fr
Ontario
Country en
CANADA
Country fr
CANADA
Fiscal year exercice financier
2015
Competition year année de concours
2016
Award amount
80716
Program id
RTI
Program name en
Research Tools and Instruments
Program name fr
Outils et instruments de recherche
Group en
Discovery grants programs
Group fr
Programmes de subventions à la découverte
Committee code
1602
Committee name en
Biological Systems and Functions (RTI)
Committee name fr
Systèmes et fonctions biologiques (OIR)
Area of application code
1101
Area of application group en
Health, education and social services
Area of application group fr
Santé publique, éducation et services sociaux
Area of application en
Human health (including medically-related psychological research)
Area of application fr
Santé publique (y compris recherche psychologique liée à la médecine)
Research subject code
5501
Research subject group en
Animal biology
Research subject group fr
Biologie animale
Research subject en
Neurophysiology
Research subject fr
Neurophysiologie
Partie
1
Nb partie
1
Application title
Transcranial Magnetic Stimulation System
Keyword
NSERC
Application summary
<p>Non-invasive brain stimulation techniques are essential for understanding neural mechanisms associated with neuroplasticity in the central nervous system (CNS). Neuroplasticity is the foundation for adaptation in the CNS associated with experience-dependent learning, sensori-motor integration and in the restoration of function following nervous system injury. Transcranial magnetic stimulation (TMS) is an effective, non-invasive brain stimulation method that involves passing current through a stimulator coil that generates a magnetic field perpendicular to the current flow. The magnetic field passes through the bone of the skull unimpeded and excites neurons in the cerebral cortex. Dr. Staines currently has a TMS unit (Medtronic / Magventure MagPro x100) that is reaching the end of its recommended lifespan (~ 10 years). The stimulation coils also require replacement every ~3-5 years. There are 2 specific coils required that allow stimulation in different frequency patterns. Such stimulation can be done with single or paired-pulse configurations to the cerebral cortex or in a repetitive mode requiring multiple stimuli to be delivered over a short time frame. One such pattern is termed theta burst stimulation (TBS) in which stimuli are delivered in burst patterns of 3 stimuli at 50 Hz delivered at a frequency of 5 Hz (theta) over a short period of time. This TBS can be delivered in different modes to either transiently excite or depress a specific area of the brain. The present request is for replacement of the current TMS system (MagPro) including 2 stimulation coils and replacement electroencephalography (EEG) caps to integrate with our current TMS and EEG (SynAmps2, Neuroscan, Compumedics) systems. This will allow the quantification of neuromodulation induced by the TMS both within and across individuals to be greatly enhanced. This is critical for studies of the neural mechanisms associated with sensorimotor neuroplasticity, cognitive neuroscience and oculomotor processes. The equipment will allow the continuation of ongoing work as well as the development of new collaborative teams. HQP from several Faculties (AHS, Science, Arts) will have access to training and use of the equipment.</p> Equipment<br /> The equipment requested is the replacement of the current TMS system including 2 stimulation coils as well as an EMG interface module for a Magventure MagPro system. The MCF-B65 coil is a statically cooled coil capable of delivering many stimuli. It is specifically required for the repetitive stimulation studies. The MC-B70 allows more focal stimulation and is important for motor mapping studies. The quote for the TMS system including the necessary stimulation coils and the EMG interface module is $70,370 after in kind educational discounts. In addition to the stimulation coils, the request includes electrode caps necessary for studies of neuromodulation in response to repetitive TMS using TBS.