Grant: Discovery Grants Program - Individual
University of Victoria
$32,000.00
Fiber-optic sensors for biomedical applications
FY 2014-15
Summary
It is widely believed that cartilage degeneration at human joints is related to how force is distributed across the joint. However, the current best practice for ex vivo measurement of contact stress in the hip is limited to static measurements only, is subject to significant measurement errors, and the procedure for its application is highly disruptive to the joint. In the proposed research, we will develop a sensor to enable minimally-invasive measurement of contact stress in ex vivo experiments in articular joints. This sensor will be based on a common fiber-optic device, the in-fiber Bragg grating. It will enable ex vivo investigations in which the natural mechanics of articular joints are preserved to a degree that is not possible with current sensor technology. The minimally-invasive nature of the sensor will: (1) reduce disruption of contact mechanics due to the presence of the sensor between the articular surfaces, and; (2) preserve natural pressurized fluid lubrication by eliminating the need to resect the joint capsule and disarticulate the joint. This sensor will also have application in both ex vivo and in vivo studies of the mechanics of prosthethic joints.In addition to the sensor development, experiments will be performed to provide ex vivo validation in an intact hip for the hypothesis that lower levels of fluid pressure resulting from labrum removal lead to higher peak magnitudes and less uniform distribution of contact stress over the articular surfaces of the hip. This study will provide the first direct insight into the relationship between these parameters in the hip. This data will inform the discussion of the role of the labrum in maintaining the health of the articular surfaces and, in conjunction with the contact stress sensor itself, will create opportunities for minimally-invasive ex vivo and potentially in vivo studies of labral function.
Program
Discovery Grants Program - Individual
Recipient
Location
British Columbia, Canada
Recipient Type
Academia
Type
Grant
Source
NSERC's Awards Data
As published
Application id
194490-2010
Name nom
Wild, Peter
Department département
Mechanical Engineering
Organization id
7
Institution établissement
University of Victoria
Province en
British Columbia
Province fr
Colombie-Britannique
Country en
CANADA
Country fr
CANADA
Fiscal year exercice financier
2014
Competition year année de concours
2010
Award amount
32000
Program id
RGPIN
Program name en
Discovery Grants Program - Individual
Program name fr
Programme de subventions à la découverte - individuelles
Group en
Discovery grants programs
Group fr
Programmes de subventions à la découverte
Committee code
1512
Committee name en
Mechanical Engineering
Committee name fr
Génie mécanique
Area of application code
515
Area of application group en
Manufacturing processes and products
Area of application group fr
Procédés et produits industriels
Area of application en
Instrumentation technology
Area of application fr
Technologie de l'instrumentation
Research subject code
2109
Research subject group en
Mechanical engineering
Research subject group fr
Génie mécanique
Research subject en
Mechanical systems and instrumentation
Research subject fr
Instrumentation et systèmes mécaniques
Partie
5
Nb partie
5
Application title
Fiber-optic sensors for biomedical applications
Keyword
NSERC
Application summary
It is widely believed that cartilage degeneration at human joints is related to how force is distributed across the joint. However, the current best practice for ex vivo measurement of contact stress in the hip is limited to static measurements only, is subject to significant measurement errors, and the procedure for its application is highly disruptive to the joint. In the proposed research, we will develop a sensor to enable minimally-invasive measurement of contact stress in ex vivo experiments in articular joints. This sensor will be based on a common fiber-optic device, the in-fiber Bragg grating. It will enable ex vivo investigations in which the natural mechanics of articular joints are preserved to a degree that is not possible with current sensor technology. The minimally-invasive nature of the sensor will: (1) reduce disruption of contact mechanics due to the presence of the sensor between the articular surfaces, and; (2) preserve natural pressurized fluid lubrication by eliminating the need to resect the joint capsule and disarticulate the joint. This sensor will also have application in both ex vivo and in vivo studies of the mechanics of prosthethic joints.In addition to the sensor development, experiments will be performed to provide ex vivo validation in an intact hip for the hypothesis that lower levels of fluid pressure resulting from labrum removal lead to higher peak magnitudes and less uniform distribution of contact stress over the articular surfaces of the hip. This study will provide the first direct insight into the relationship between these parameters in the hip. This data will inform the discussion of the role of the labrum in maintaining the health of the articular surfaces and, in conjunction with the contact stress sensor itself, will create opportunities for minimally-invasive ex vivo and potentially in vivo studies of labral function.