Development of a reliable pre-concentrator for a paper-based microfluidics device in water monitoring

FY 2012-13

Summary
The main goal of this project is to develop a reliable pre-concentrator system that can supply to a secondary detection system, likely a paper-based microfluidic device, for monitoring E. coli in water. In particular, the key milestones for the project would be: (i) To design a pre-concentrator to increase the target molecule count; (ii) To fabricate the pre-concentrator; (ii) To explore possible mechanisms to integrate the pre-concentrator with the real-time paper-based water monitoring device with the industry partner. The pre-concentration of E. coli will be performed by using on-chip dielectrophoresis within the paper-microfluidics device. Dielectrophoresis requires a non-uniform electrical field, which will be achieved by patterning gold electrode on the paper-microfluidic device. Dielectrophoresis will allow concentrating cells at a given location at the electrode surface. Commercial implementation routes in water monitoring will be investigated by our strategic collaborator, Stream Technologies Inc. (STI), an Edmonton based company. STI have been working on rapid pathogen detection systems along with their sister company D-TEX, for about 6 years. The biggest challenge identified by them and other industries related to water monitoring sensor is certainly 'sample preparation'. Regardless of the particular application (eg., environmental monitoring, water safety, food safety, medical diagnostics), screening a relatively large volume sample for very few numbers of organisms (or low concentrations of target analyte) is the number one factor in determining the limit of detection sensitivity. This proposal provides a very reasonable solution and STI look forward to collaborating with us to develop a commercial viable solution for sample pre-concentration.
Program
Engage Grants Program
Location
Alberta, Canada
Recipient Type
Academia
Type
Grant
Source
NSERC's Awards Data

As published

Application id
444886-2012
Name nom
Mitra, SushantaK
Department département
Mechanical Engineering
Organization id
9
Institution établissement
University of Alberta
Province en
Alberta
Province fr
Alberta
Country en
CANADA
Country fr
CANADA
Fiscal year exercice financier
2012
Competition year année de concours
2012
Award amount
25000
Program id
EGP
Program name en
Engage Grants Program
Program name fr
Programme de subventions d'engagement partenariat
Group en
Research partnerships programs
Group fr
Programmes de partenariat
Committee code
1555
Committee name en
Prairie Internal Decision Committee
Committee name fr
Comité de décision interne pour les Prairies
Area of application code
702
Area of application group en
Transportation systems and services
Area of application group fr
Services et systèmes de transport
Area of application en
Water
Area of application fr
Maritime
Research subject code
2100
Research subject group en
Mechanical engineering
Research subject group fr
Génie mécanique
Research subject en
Mechanical engineering
Research subject fr
Génie mécanique
Partie
1
Nb partie
1
Application title
Development of a reliable pre-concentrator for a paper-based microfluidics device in water monitoring
Keyword
NSERC
Application summary
The main goal of this project is to develop a reliable pre-concentrator system that can supply to a secondary detection system, likely a paper-based microfluidic device, for monitoring E. coli in water. In particular, the key milestones for the project would be: (i) To design a pre-concentrator to increase the target molecule count; (ii) To fabricate the pre-concentrator; (ii) To explore possible mechanisms to integrate the pre-concentrator with the real-time paper-based water monitoring device with the industry partner. The pre-concentration of E. coli will be performed by using on-chip dielectrophoresis within the paper-microfluidics device. Dielectrophoresis requires a non-uniform electrical field, which will be achieved by patterning gold electrode on the paper-microfluidic device. Dielectrophoresis will allow concentrating cells at a given location at the electrode surface. Commercial implementation routes in water monitoring will be investigated by our strategic collaborator, Stream Technologies Inc. (STI), an Edmonton based company. STI have been working on rapid pathogen detection systems along with their sister company D-TEX, for about 6 years. The biggest challenge identified by them and other industries related to water monitoring sensor is certainly 'sample preparation'. Regardless of the particular application (eg., environmental monitoring, water safety, food safety, medical diagnostics), screening a relatively large volume sample for very few numbers of organisms (or low concentrations of target analyte) is the number one factor in determining the limit of detection sensitivity. This proposal provides a very reasonable solution and STI look forward to collaborating with us to develop a commercial viable solution for sample pre-concentration.