Canada Spends Logo

Explore our Budget 2026 analysis

Grant: Discovery Grants Program - Individual

Carleton University

$36,000.00

Development of Monte Carlo techniques for radiation transport simulations and application to radiotherapy physics and dosimetry

FY 2019-20

Summary
The 2011 AAPM summer school for medical physicists was on the subject of Uncertainties in External Beam Radiation Therapy. The opening plenary speaker argued that the issues that were most likely to impact patient outcomes were dose calculation accuracy and calibration accuracy because these issues affect every one of a patient's many treatments. The goal of this research program is to improve the dosimetry of radiotherapy delivery by providing accurate research tools for calculating dose distributions from traditional and emerging technologies and by providing new information needed to accurately use different types of radiation dosimeters.**The program consists of four broadly linked areas of research.**For over 25 years the PI has been deeply involved with the development of the EGS system which is used to simulate the transport of radiation through matter. EGSnrc is considered the gold standard for such software. However, with the emergence of combined MRI-radiotherapy systems, it is essential to extend the EGSnrc system to work in the presence of magnetic fields which can have a strong influence both on the dose delivered and on some of the instruments used to measure it. Other improvements to be made will maintain the code's accuracy and significantly increase its efficiency. Measurements will be made in collaboration with the standards lab at NRC to verify the accuracy of the calculations. These improvements will be made available to researchers around the world so they may independently verify the new MRI-therapy systems and more efficiently study many other problems.**The second research area is the calculation of correction factors for ion chambers which are used to measure the dose in radiation therapy treatments. Values recently calculated by the PI's group for use in linac photon beams have been recommended for clinical use throughout North America. In this program, calculations and measurements will be done for the more complex case of electron beams and corrections for low-energy x-ray beams will be calculated.**The third research area is to extend our recent work on TLD dosimeters to a wide range of clinical detectors. With the software now available, we are able to much more accurately model detector response and investigate the effects of realistic models of the detectors. Within the conceptual framework popularized by the 2009 AAPM summer school, it is now possible to more clearly characterize detector's response. Our research on TLD detectors showed that there are many subtleties which most clinical physicists were unaware of. The goal is to use Monte Carlo simulations to clarify these types of issues for a wide variety of detectors (e.g., diodes, OSL detectors, MOSFETS, radiochromic film) so they may be used with confidence to ensure accurate radiotherapy.**The final component is the extraction of photon spectra from measured depth-dose curves. Previous approaches suffered from a variety of problems but, by introducing an accurate correction for electron contamination, using dual detectors with different properties to measure the depth-dose curves, using our recently developed functional form to represent the bremsstrahlung spectra and explicitly accounting for the detector's response with depth in the phantom, this research program will overcome the previous problems and provide a robust way to accurately determine clinical accelerator spectra which are needed for the calculation of dose distributions in the patient.**While these four components of the research program will not provide any dramatic improvements in cancer treatment, collectively they will have a significant impact on how well radiation therapy is delivered and hence improve patient care by improving our physics understanding of dosimetry.
Program
Discovery Grants Program - Individual
Location
Ontario, Canada
Recipient Type
Academia
Type
Grant
Source
NSERC's Awards Data

As published

Application id
RGPIN-2014-05340
Name nom
Rogers, David
Department département
Physics
Organization id
23
Institution établissement
Carleton University
Province en
Ontario
Province fr
Ontario
Country en
CANADA
Country fr
CANADA
Fiscal year exercice financier
2019
Competition year année de concours
2014
Award amount
36000
Program id
RGPIN
Program name en
Discovery Grants Program - Individual
Program name fr
Programme de subventions à la découverte - individuelles
Group en
DISCOVERY RESEARCH
Group fr
RECHERCHE AXÉE SUR LA DÉCOUVERTE
Committee code
1505
Committee name en
Physics
Committee name fr
Physique
Area of application code
518
Area of application group en
Manufacturing processes and products
Area of application group fr
Procédés et produits industriels
Area of application en
Medical equipment and apparatus
Area of application fr
Appareils et instruments médicaux
Research subject code
3114
Research subject group en
Physics
Research subject group fr
Physique
Research subject en
Biological and Medical Physics
Research subject fr
Physique biologique et médicale
Installment
inst:5 - 5
Partie
5
Nb partie
5
Application title
Development of Monte Carlo techniques for radiation transport simulations and application to radiotherapy physics and dosimetry
Keyword
NSERC
Application summary
The 2011 AAPM summer school for medical physicists was on the subject of Uncertainties in External Beam Radiation Therapy. The opening plenary speaker argued that the issues that were most likely to impact patient outcomes were dose calculation accuracy and calibration accuracy because these issues affect every one of a patient's many treatments. The goal of this research program is to improve the dosimetry of radiotherapy delivery by providing accurate research tools for calculating dose distributions from traditional and emerging technologies and by providing new information needed to accurately use different types of radiation dosimeters.**The program consists of four broadly linked areas of research.**For over 25 years the PI has been deeply involved with the development of the EGS system which is used to simulate the transport of radiation through matter. EGSnrc is considered the gold standard for such software. However, with the emergence of combined MRI-radiotherapy systems, it is essential to extend the EGSnrc system to work in the presence of magnetic fields which can have a strong influence both on the dose delivered and on some of the instruments used to measure it. Other improvements to be made will maintain the code's accuracy and significantly increase its efficiency. Measurements will be made in collaboration with the standards lab at NRC to verify the accuracy of the calculations. These improvements will be made available to researchers around the world so they may independently verify the new MRI-therapy systems and more efficiently study many other problems.**The second research area is the calculation of correction factors for ion chambers which are used to measure the dose in radiation therapy treatments. Values recently calculated by the PI's group for use in linac photon beams have been recommended for clinical use throughout North America. In this program, calculations and measurements will be done for the more complex case of electron beams and corrections for low-energy x-ray beams will be calculated.**The third research area is to extend our recent work on TLD dosimeters to a wide range of clinical detectors. With the software now available, we are able to much more accurately model detector response and investigate the effects of realistic models of the detectors. Within the conceptual framework popularized by the 2009 AAPM summer school, it is now possible to more clearly characterize detector's response. Our research on TLD detectors showed that there are many subtleties which most clinical physicists were unaware of. The goal is to use Monte Carlo simulations to clarify these types of issues for a wide variety of detectors (e.g., diodes, OSL detectors, MOSFETS, radiochromic film) so they may be used with confidence to ensure accurate radiotherapy.**The final component is the extraction of photon spectra from measured depth-dose curves. Previous approaches suffered from a variety of problems but, by introducing an accurate correction for electron contamination, using dual detectors with different properties to measure the depth-dose curves, using our recently developed functional form to represent the bremsstrahlung spectra and explicitly accounting for the detector's response with depth in the phantom, this research program will overcome the previous problems and provide a robust way to accurately determine clinical accelerator spectra which are needed for the calculation of dose distributions in the patient.**While these four components of the research program will not provide any dramatic improvements in cancer treatment, collectively they will have a significant impact on how well radiation therapy is delivered and hence improve patient care by improving our physics understanding of dosimetry.