Grant: Engage Plus Grants Program
Carleton University
$12,500.00
Amplifier Interface Design for Real-Time Simulation of Phasor Measurement Unit
FY 2017-18
Summary
The use of phasor measurement unit (PMU), also known as synchrophasors, for monitoring of electrical powersystem states, stability and health, experiences an increasing growth throughout the world and especially inNorth America. The creation of the North American Synchrophasor Initiative (NASPI), for instance, has drawnthe attention of researchers and utilities worldwide and has helped in increasing the quality of research in thatarea. The Institute of Electrical and Electronics Engineers Standards Association (IEEE-SA) has issuedstandards on the performance requirements of PMUs and the test equipment required to achieve certification.These tests as well as the requirements for the test equipment are known to be very stringent. PMUs need to bevery accurate to ensure the best possible visualization of the grid condition and ensure reliability of the futureadvanced controls.A synergy between Canadian companies, namely Hydro-Quebec's Research institute (IREQ), Vizimax andOPAL-RT Technologies, have led to interesting developments in the area of synchrophasors. OPAL-RT andIREQ signed a strategic collaboration agreement for the shared commercialization and development ofHYPERSIM in 2012. There has also been an agreement between Vizimax and IREQ for the integration ofestimation algorithms resulting from research at IREQ. The algorithms have been enhanced by Vizimax foraccurate real-time estimation and standard compliance and the resulting PMU is commercialized by Vizimax.In 2015 and 2016, OPAL-RT has collaborated with VIZIMAX in order to help them prepare for the officialIEEE certification, by developing the required test rig on their real-time simulation platform HYPERSIM. TheVizimax PMU is now the second one worldwide which has passed the certification program. To OPAL-RT,this consisted in Phase 1 for the development of an integrated test platform and there are multiple other featuresto develop to make sure the platform can be used for official certification.
Program
Engage Plus Grants Program
Recipient
Location
Ontario, Canada
Recipient Type
Academia
Type
Grant
Source
NSERC's Awards Data
As published
Application id
510611-2017
Name nom
Wang, Xiaoyu
Department département
Electronics
Organization id
23
Institution établissement
Carleton University
Province en
Ontario
Province fr
Ontario
Country en
CANADA
Country fr
CANADA
Fiscal year exercice financier
2017
Competition year année de concours
2017
Award amount
12500
Program id
EGP2
Program name en
Engage Plus Grants Program
Program name fr
Programme de subvention d'engagement partenarial Plus
Group en
Research partnerships programs
Group fr
Programmes de partenariat
Committee code
1553
Committee name en
Ontario Internal Decision Committee
Committee name fr
Comité de décision interne pour l'Ontario
Area of application code
304
Area of application group en
Energy resources
Area of application group fr
Ressources d'énergie
Area of application en
Electrical energy
Area of application fr
Énergie électrique
Research subject code
2501
Research subject group en
Electrical and electronic engineering
Research subject group fr
Génie électrique et électronique
Research subject en
Power systems
Research subject fr
Réseaux électriques
Partie
1
Nb partie
1
Application title
Amplifier Interface Design for Real-Time Simulation of Phasor Measurement Unit
Keyword
NSERC
Application summary
The use of phasor measurement unit (PMU), also known as synchrophasors, for monitoring of electrical powersystem states, stability and health, experiences an increasing growth throughout the world and especially inNorth America. The creation of the North American Synchrophasor Initiative (NASPI), for instance, has drawnthe attention of researchers and utilities worldwide and has helped in increasing the quality of research in thatarea. The Institute of Electrical and Electronics Engineers Standards Association (IEEE-SA) has issuedstandards on the performance requirements of PMUs and the test equipment required to achieve certification.These tests as well as the requirements for the test equipment are known to be very stringent. PMUs need to bevery accurate to ensure the best possible visualization of the grid condition and ensure reliability of the futureadvanced controls.A synergy between Canadian companies, namely Hydro-Quebec's Research institute (IREQ), Vizimax andOPAL-RT Technologies, have led to interesting developments in the area of synchrophasors. OPAL-RT andIREQ signed a strategic collaboration agreement for the shared commercialization and development ofHYPERSIM in 2012. There has also been an agreement between Vizimax and IREQ for the integration ofestimation algorithms resulting from research at IREQ. The algorithms have been enhanced by Vizimax foraccurate real-time estimation and standard compliance and the resulting PMU is commercialized by Vizimax.In 2015 and 2016, OPAL-RT has collaborated with VIZIMAX in order to help them prepare for the officialIEEE certification, by developing the required test rig on their real-time simulation platform HYPERSIM. TheVizimax PMU is now the second one worldwide which has passed the certification program. To OPAL-RT,this consisted in Phase 1 for the development of an integrated test platform and there are multiple other featuresto develop to make sure the platform can be used for official certification.